Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: M (SI Unit Only)

Series: 3 (VQZ300), Composite Symbol: 1 (Metal Seal N.C.), Function: B (High Speed Response, 0.9W), Coil Voltage: 5 (24VDC), Lead Wire: YO (DIN Terminal w/o Connector), Manual Override: Non-locking Push Style, IP65 Compliant: None, Port Size: C6 (ø6 One-touch Fitting), Option: F (Bracket), CE Compliant: Q (CE Marked)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration

Magnet: D (Built-in Magnet), Mounting: U (Rod Trunnion), Bore Size: 40mm, Thread: Rc, ø20 to ø100, Stroke: 125mm, Rod End Thread: Male Rod End, Pivot Bracket: N (Pivot Bracket), Rod End Bracket: Q (Rod End)

Series CA2*Q is a low friction version of the light weight tie rod air cylinder.  Designed with low priston sliding resistance, this cylinder is ideal for applications such as contact pressure control. Low friction is in one direction only.  A variety of auto switches are available for mounting, including compact switches and magnetic field resistant switches.  

The VBAT-Q tanks are CE certified for use in Europe and other countries that require compliance wtih the European Pressure Equipment Directive (PED).  These units include a CE marked pressure relief valve and a drain valve. Tank capacity: 5, 10, 20, or 38 liters; Material: carbon steel (SS400); Connection ports: Rc (PT) or G; Pressure rating: 290 psi (5, 10 liter), 145 psi (20, 38 liter)

The IP8101-X419-Q allows for the remote control of cylinders by installing a position detection sensor on the cylinder.  The IP8101-X419 offers a convenient and easy way of control and monitorization of the cylinder from up to 10-meter piping length. 

Symbol: 155R (3 Port, Universal), Function: Y (Standard w/Power Saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: 1U (1/4-28UNF, PVDF), Lead Wire Length: KZ (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 3 (Common), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: Base Mounted w/o Sub-plate, Thread: Rc, Option: None, CE Compliant: Q (CE Compliant)

Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation

Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JK (with Unit Options J & K), 1st Nominal Nozzle Size: 0 (for

Stations: 07 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation

Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release

Stations: 04 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release

Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal Nozzle Size: 0 (for Vacuum

Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2 (PFA, M6), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)

Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)

Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2 (PFA, M6), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)

Size: 32, Type: Q (Rapid Supply and Exhaust Function), Thread: N (NPT), Port Size: 02 (1/4), Tubing O.D: 09 (5/16")

Classification of Waterproof: 1 (Drip Proof/Rain Proof), Set Flow: 0 (14 to 60 l/min), Thread: Rc(PT), Port Size: 06 (3/4), Fluid Contact Area Material: 0 (Copper Alloy), Seal Material: 1 (FPM), CE-compliant: Q (CE-compliant)