Grommet: VKF334-G-01 DIN terminal: VKF334-D-01 Base mounted type 33.5 16.7 26 4 Manual override (non-locking) A 12.7 20 10 18.5 20.5 3 32 71.5 Max. 10 2-4.3 (mounting holes) Applicable cord O.D. 4 to 6.5 48.5 Approx. 300 (lead wire length) 26 4 Pg.7 3 27 Manual override (non-locking) A 20.5 18.5 3 32 59 68 78 70.5 43.5 12 7.5 P R 13.5 11 33.5 7.5 12 43.5 P R 3-Rc(PT) 1/8 (ports P, A, R) 13.5
(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8
pressure range 1.3 x 10-7 Pam3/sec or less (at normal temperatures, excluding gas permeation) Leakage Maximum baking temperature 150C Ambient and fluid temperature 10 to 60C Piston speed 50 to 300 mm/s Stroke adjustment 2 to 0 mm on each side (4 to 0 mm total) Cushion Sine cushion (Air cushion) Port size 5/16-24 UNF 7/16-20 UNF Vacuum grease for linear guide unit and inside the cylinder
5 4 16 10 to 60 80.5 M4 x 0.7 70.5 8 8 36 11.5 M6 x 1.0 47 7 10 25.5 5.4 9 48.5 10 5 7 20 10 to 60 89 M5 x 0.8 79 10 10 40 12 M6 x 1.0 52 8 10 28 5.4 9 55 10 6 7 25 10 to 50, 75, 100 96.5 M6 x 1.0 84.5 12 12 45 13.5 M6 x 1.0 60 4.5 10 12 34 5.5 9 58 10 49.5 7 7 28 10 to 50, 75, 100 116 M8 x 1.25 104 13 16 52 17.5 M6 x 1.0 69 5 14 12 40 5.5 9 71 10 57 10 7 With rod end male thread: MQQDM
D W E M K L B + Stroke 0.2 A + Stroke M E Bore size (mm) Stroke range (mm) A OA B C D E F H RB I J K L M N OB Q RA W Y 10 10 to 40 39.5 M4 x 0.7 31.5 6 6 29 5.5 M3 x 0.5 4 38 5 8 20 3.5 6.5 14.5 7 5 16 10 to 60 44 M6 x 1.0 34 8 8 36 5.5 M4 x 0.7 7 47 7 10 25.5 5.4 9 18 10 5 20 10 to 60 47.5 M6 x 1.0 37.5 10 10 40 5.5 M5 x 0.8 7 52 8 10 28 5.4 9 19.5 10 6 25 10 to 50, 75, 100 54 M6 x
[L/min (ANR)] 06, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
11.5 For latching solenoid or AC solenoid 43.5 300 U side D side Stations 5 4 3 2 1 n 300 42.2 36.3 16.4 12.5 A A 7.5 n-M5 A port Dimensions Equation/ L1=10n+13, L2=10n+7, n:Stations (Max.20 stations) L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 23 33 43 53 63 73 83 93 103 113 123 133 143 153 163 173 183 193 203 213 L2 17 27 37 47 57 67 77 87 97 107 117 127 137 147 157 167 177
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
AS42l1FE AS43l1FE Model 8 10 6 8 10 12 12 10 6 8 10 Tube O.D.
Model RZQ32 RZQ40,50 RZQ63 Applicable floating joint JB40-8-125 Graph 1 JB63-10-150 200 JB80-16-200 63 100 Guide Shock absorber 50 Load weight (kg) 50 40 40 32 30 Floating joint 3 position cylinder 20 10 Maintenance Caution 5 150 100 200 300 1.
type Ground ball screw Rolled ball screw 6 10 20 10 20 10 20 10 20 6 10 20 10 20 10 20 10 20 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 P.2 Horizontal 10 10 P.10 Standard motor 6 6 P.18 Vertical 10 10 P.26 Frame-type linear guide LTF 6 6 P.34 Horizontal 10 10 P.42 Non-standard motor 6 6 P.50 Vertical 10 10 P.58 Options P.66 Construction P.67 Mounting P.68 Non-standard Motor Mounting
1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min
LAT3LAT3MLAT3F600 350 700 Min. travel time [ms] Min. travel time [ms] Min. travel time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
Contact protection box CD-P11 LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator
PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to
L1 E1 R1 U1 A1 U1 R1 A MM NDH10 NZ MM NDH10 NX NX E1 L1 30 40 50 60 60 20 22 28 40 40 12 12.5 16.5 23.5 23.5 16 19 24 34 34 32 40 50, 63 80 100 32 40 50, 63 80 100 14 19 24 26 26 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 M10x1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20
(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. Note) A DIN rail with the length specified by the number of stations is attached to the manifold.