W Mounting orientation: Horizontal Operating pressure: 0.5 MPa Allowable Lateral Load at Rod End Standard Type: MQQTB Anti-lateral Load Type: MQQLB/Built-in Ball Bushing Type 60 5 50 4 Maximum allowable lateral load W (N) Maximum allowable lateral load W (N) 28 40 3 28 25 30 25 2 20 20 20 16 16 1 10 10 10 30 60 75 100 30 60 75 100 Stroke (mm) Stroke (mm) Note 1) The allowable lateral load
(mm) Symbol 1 2 3 Note 2) Port size Rc 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking
5 Pilot valve assembly How to Order Pilot Valve Assembly SCZ2 G 1 1 Rated voltage Series VZ200 1 100 VAC, 50/60 Hz Pilot pressure exhaust Manual override Electrical entry 2 200 VAC, 50/60 Hz 1 Spacer side exhaust (Type 20) 3 110 VAC, 50/60 Hz Nil Push type (Safety style) G H L LN L plug connector With lead wire 600 mm lead wire 300 mm lead wire 4 220 VAC, 50/60 Hz Grommet B Locking type
B 23 () (+) Grey Red 11 () (+) White Red SOL. A Station 11 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Station 12 SOL. B 25 () (+) White None COM. 13 (+) () Orange Red Note) Negative COM. spec. Positive COM. spec. Note) When using the negative COM. specification for VQC1000/2000, use valves for negative COM.
88 6 540 MXW25-225 175 305 165 55 55 245 84 113 7 590 1 MXW25-250 200 335 187 67 60 275 109 138 7 640 1 MXW25-275 225 360 210 80 65 300 134 163 7 690 1 MXW25-300 245 395 232 52 60 60 320 159 188 8 740 2 8-7-19 20 Series MXW Construction !
NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber NBR Silicon rubber ZP02 ZP04 ZP06 ZP08 ZP10 ZP13 ZP16 ZP20 ZP25 ZP32 ZP40 ZP50 ZP63 ZP80 ZP100 ZP125 5 7 8 2 2 4 4 7 9 11 2 4 5 7 10 4 6 8 10 5 5 10 10 7 9 9 10 13 10 8 13 11 13 11 10 11 16 20 25 32 12 14 9 9 13 15 19 25 33 13 15 20 26 35 14 17 20 24 30 15 18 21 26 33 14 14 13 20 18 12 13 11 17
20 56 76 280 MHL2-10D1Z 40 40 78 118 355 10 MHL2-10D2Z 60 96 156 430 MHL2-16DZ 60 30 68 98 525 MHL2-16D1Z 40 60 110 170 725 16 MHL2-16D2Z 80 130 210 845 MHL2-20DZ 60 40 82 122 940 MHL2-20D1Z 40 80 142 222 1335 20 Symbol MHL2-20D2Z 100 162 262 1520 Double acting: External grip Double acting: Internal grip MHL2-25DZ 60 50 100 150 1565 MHL2-25D1Z 40 100 182 282 2295 25 MHL2-25D2Z 120 200 320
NS 14 14 24 24 30 30 45 55 60 LT 42 42 52 52 62 62 72 82 92 LB 20 25 30 LA 10 10 20 20 30 30 20 25 30 J 4 4 4 4 4 4 6 6 6 Stroke (mm) 5 10 15 20 25 30 40 50 60 24 Compact Slide MXH Series Dimensions: 10 LT MXH MXH 19 11 MXS MXQ 11 LA LB J x M4 x 0.7 Depth 6 MXQ 3 x M5 x 0.8 through Pilot hole dia 4.3 2 x 3 x 7.5 counterbore depth 4.4 MXF 2 x 2 x M5 x 0.8 Cylinder port (With plug for port)
It is already built-in to the rectifier circuit. 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch Refer to the table below for selecting applicable auto switches.
AC AC Note) SYJ300 LPush-locking slotted style LWith indicator light and surge voltage suppressor 50 60 50 L100V AC / Hz 110V AC / Hz 200V AC / Hz 220V AC / Hz 1.8 (0.1) 60 50 M5 X 0.8 60 50 60 SYJ500 4.5 (0.25) Rc(PT)1/8 SYJ700 9.0 (0.5) Rc(PT) 1 8 / 1 4 Note) All AC voltage models have built-in surge voltage suppressor. 2.2-2 Series SYJ300/500/700 Manifold Variations A port size With built-in
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Servo amp lifier Driver (Note 7) (Note 7) CN1 CN1 (Note 2) 24VDC RA1 (Note 4, 9) 2 OPC 9 ALM Trouble (Note 6) 1 DICOM Travel completion 10 MEND RA2 13 DOCOM (Note 9, 11) (Note 13) Ready EM1 SON MD0 8 4 3 (Note 3, 5) Forced stop 11 RD RA3 Servo-on Electromagnetic brake interlock 12 MBR RA4 Automatic/manual selection DOG (Note 9, 10, 12) 25 Proximity dog 10m max. Point table No.
When the Hysteresis exceeds 10m use the Air-Catch Sensor as a confirmation of position of work piece. : Stable adjustment range Detection side nozzle: 1.0 Detection side piping: 6 X 4 tubing Detection side nozzle: 2.0 Detection side piping: 6 X 4 tubing Detection side nozzle: 1.5 Detection side piping: 6 X 4 tubing 70 70 70 60 60 60 Supply pressure Supply pressure Detection not possible 50
74 94 09 11 14 09.5 16.0 15.0 M8 x 1.25 M10 x 1.5 PA PG 7 8 9 Bore size (mm) 25 32 40 P Rc 1/8 Rc 1/8 Rc 1/4 SS 5.1 4.0 9.0 PB 112 134 150 PP1 12.7 15.5 17.5 PP2 12.7 18.5 20 Q 206 264 322 QQ 16 16 26 QW 46 60 72 RR1 18.9 22.0 RR2 17.9 24.0 TT 15.5 21.0 26.0 UU 16 16 21 VV 16 19 23 W 122 144 160 WW 11 13 20 YW 070 088 104 Z 240 300 360 60 80 100 25.50 29 .0 Hole sizes for centralized piping
Bottom Ported How to Order Manifold SS5Y S6 10 3 Q C6 2 05 U Refer to the SY3000/5000 series catalog (CAT.ES11-103) for Type 11/Bottom ported dimensions.
PLC No. 1-051 <> PLC 15ms 30ms 2(P.60) No.
24 40 M4 x 0.7 11 10.5 30 27 24 19 M8 x 1.0 6 40 20 3.5 16 60 17.5 85 103 77 1.0 0.5 12.5 30 60 M4 x 0.7 M8 x 1.0 8 68 26 4.3 20.5 80 PA dimensions are for split from center.
18 6.5 34 4.5 54 14 0.15 20 0.15 7 30 MKB40 65 29.5 35 9 Depth 7 M10 X 1.5 94.5 Rc(PT)1/8 52 5.5 12 16 3 8 69 18 6.5 40 5 61 14 24 7 30 0 0.062 0 0.062 0.15 0.15 MKB50 11 Depth 8 M12 X 1.75 112 76.5 34 10.5 41 Rc(PT)1/4 64 6.6 15 20 3.5 86 22 7.5 50 7 73 0.15 30 0.15 8 37 17 MKB63 80 M12 X 1.75 115 35 10.5 47.5 Rc(PT)1/4 77 9 15 20 3.5 103 22 7.5 60 7 86 35 9 48 17 14 Depth 10.5 Note 1)
VEX5511-062EZ-BG Body size 5, Select, External pilot solenoid Port size 3/4 200 VAC, Grommet terminal, with light/surge voltage suppressor OptionBracket, with pressure gauge 5 3 4 200 VAC 50/60 Hz 1 1 1 110 VAC 50/60 Hz 4 7 220 VAC 50/60 Hz 24 VDC 12 VDC 11 4 11 4 5 6 11 2 9 2 2 7 240 VAC 50/60 Hz Other 9 Option Thread type Nil F N T Rc G(1) NPT NPTF Note 1) Not conforming to ISO1179-1.