Body Size: 20, Thread: NPT, Port Size: 1/4, Option: N.C. Float Type Auto Drain, Attachment: T + V, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F

Body Size: 20, Thread: NPT, Port Size: 1/4, Option: Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator, Attachment: T + V1, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F

Body Size: 20, Thread: NPT, Port Size: 1/4, Option: C + G, Attachment: T + V, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F

Body Size: 20, Thread: NPT, Port Size: 1/4, Option: C + G, Attachment: 3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F

Body Size: 20, Thread: NPT, Port Size: 1/4, Option: C + G, Attachment: 3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F

Body Size: 20, Thread: NPT, Port Size: 1/4, Option: Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator, Attachment: 3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units:

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: CG (C + G), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: CG (C + G), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: TV1 (T + V1), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Attachment: Pressure Switch, Option 1: None, Option 2: C [Bowl Guard (Size 2000 Only)], Option 3: Name Plate, Caution Plate for Bowl, and Pressure Gauge: PSI, °F

Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Attachment: Pressure Switch, Option 1: None, Option 2: C [Bowl Guard (Size 2000 Only)], Option 3: Name Plate, Caution on Bowl

Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Piping Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm.

If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration