, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: [With Standard Pressure Gauge] Round-shaped pressure gauge (with limit indicator), Size of Body: 25, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Drain Outlet: N/A,

Body Size: 25, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 25, Thread: N (NPT), Port Size: 02 (1/4), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

For a facility having a small installation area (that cannot vent the air naturally): Make a forced air exhaust vent in a wall at a high level and an air inlet in a wall at a low level.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

During Auto tuning Auto tuning failure A T 1 E R R 1 9 P V < 2 3 . 0 C # 1 A T F a i l u r e A u t o T u n i n g M O D E S h u t O f f C a n c e l : A T k e y <4> External sensor sampling cycle setting: Mode indication External Sensor Sampling Cycle. Default value: 180 sec. Setting range 10 to 999 sec.

Caution : CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Indicates the offset value of the air temperature used as reference value by the controller (SV + Offset). Sets upper limit of temperature range which causes a warning to occur. Sets lower limit of temperature range which causes a warning to occur. Sets parity bit for communication.

Body Size: 3000, Port Thread: F (G), Port Size: 03 (3/8), Option: None, Flow Direction, Pressure Unit: Flow Direction: Left to Right

Body Size: 3000, Port Thread: F (G), Port Size: 03 (3/8), Option: None, Voltage: None - Manifold Override, Electrical Entry: None - Manifold Override, Surge Suppressor: None or Manual Override, Flow Direction, Pressure Unit: Flow Direction: Left to Right

Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 1 (Front Exhaust), Thread: F (G), Port Size: 03 (3/8), Option: None, Semi-standard: None

Body Size: 3, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 03 (3/8), Option: None, Semi-standard: None

Body Size: 3, Set Pressure: 1 (1.5 to 58 psi [0.01 to 0.4 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 03 (3/8), Option: None, Semi-standard: None

Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 03 (3/8), Option: None, Semi-standard: None

Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 2 (Rear Exhaust), Thread: F (G), Port Size: 03 (3/8), Option: None, Semi-standard: None

Model: Y410 [Applicable Models: AC40-(A/B), AC40B-(A/B), AC40C-(A/B)], Thread: F (G), Port Size: 03 (3/8)