SMC Corporation of America
Elite Part Number Search
Search Results "AC40B-N04-Z-A"

Body Size: 40, Thread: NPT, Port: 1/2, Option: Standard, Attachment: T + V1, Semi-Standard 1: Standard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F

Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: Mounting Position: AF + AFM + AR + V, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z

Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: Mounting Position: V + AF + AR*K, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z

Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: Standard, Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: Standard, Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: Standard, Attachment: SV1 (S + V1), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: Standard, Attachment: SV (S + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: Standard, Attachment: TV1 (T + V1), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Filter, Drain Storage Capacity(cm3): -, Drain Cock: [Not Provided] No, Pressure Gauge: [None (Pressure Port Plug Available)] No Pressure Gauge, Size of Body: 40, Check Valve: None, Pressure Switch: Yes, Residual Pressure Relief 3-Port Connection Valve: Yes, Set Pressure: 0.05 to 0.85 MPa, Drain Outlet: N/A,

Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Filter, Drain Storage Capacity(cm3): -, Drain Cock: [Not Provided] No, Pressure Gauge: [None (Pressure Port Plug Available)] No Pressure Gauge, Size of Body: 40, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: Yes, Set Pressure: 0.05 to 0.85 MPa, Drain Outlet: N/A,

Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Filter, Drain Storage Capacity(cm3): -, Drain Cock: [Not Provided] No, Pressure Gauge: [None (Pressure Port Plug Available)] No Pressure Gauge, Size of Body: 40, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: Yes, Set Pressure: 0.05 to 0.85 MPa, Drain Outlet: N/A,

Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The

Caution: Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

C Accessories Technical Notes Applicable body size Outlet port size (NPT) AFW150 AFW-CK150 AFW-BK150 AFW-E150-N04 AFW-E150-N06 AFW-E150-N10 AFW-E150-14 N/A Description AFW225-650 AFW-CK650 AFW-BK650 N/A N/A N/A AFW-E650-N14 AFW-E650-N20 AFW1000-1500 AFW-CK1500 AFW-BK1500 N/A N/A N/A N/A N/A Connection kit Mounting bracket kit (2 per kit) 1.

Then, a correct operation works until a vacuum pressure proportional to the input signal is reached, and a vacuum pressure is obtained which is always proportional to the input signal.

Nole 5) When mounting a blanking plate and lhe regulator with diflerent pressure set. olease inlorm SI C ol the oder ol a manifold stalion beside a purchase order, Nole) Refer to the table below tor possible mixed combination, Uod.l rvl03tr tTvl05tl tw201tr rTv203tr tw205tr tw10ltr o tw103tr o a a o tTV't05tr o o a a trv20ttr o o tTV203tr o o a a tTV205tr o o a o Pressure response wilh no

To connect a drain discharge pipe, use a pipe with a minimum bore of 10, and a maximum length of 5 m. Avoid using a riser pipe.

If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.

M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS