C B A stroke A C 3) 2nd stage: B-A stroke operation Following the 1st stage, when the air pressure is supplied from the C port, the rod operates the B-A stroke. B B-A stroke B A C 4) Cylinder retraction When the air pressure is supplied from the B port, the rod retracts completely. B stroke A stroke A stroke or B stroke operation can be made individually.
Air operated style fluid control valve Vacuum valve Vacuum pad 2(A) 1(P) 2(A) 1(P) 2(A) 1(P) 2(A) 3(P) 3(R) 3(R) 3(R) 1(R) Atmospheric air or micro pressure for vacuum release 22 Multi-purpose Valve Series VCA Direct Operated 2 Port Solenoid Valve for Air Improved durability (Nearly twice the life of the previous series) Operating resistance of moving parts reduced for improved longevity
A 3 position pressure centre solenoid valve and regulator with check valve can be replaced with two 3 port normally open valves and a regulator with relief function.
SMC FLOW SWITCH Blue 5 1 12 to 24VDC Series PF2W5 35.8 A 40 UNIT RESET PF2W30-A SET Panel fitting dimension 8-M3 3 x 7.2 (= 21.6) 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black 1 2 3 4 7 3 Load +0.5 0 Brown 19.4 6 2 + 36 Blue 5 1 12 to 24VDC 5 6 7 8 Series PF2W5 PF2W31-A The applicable panel thickness is 1 to 3.2mm.
A Sets alarm which is selected for contact output 2. [-] is displayed when the setting of the output signal of contact output2 is not selected alarm signal. Contact output signal 2 ---(AL.01) selected alarm Contact output signal 3 function Sets output signal function of contact output 3. ALM Contact output signal 3 operation Sets output signal operation of contact output 3.
A Sets alarm which is selected for contact output 2. [-] is displayed when the setting of the output signal of contact output2 is not selected alarm signal. ---(AL.01) Contact output signal 2 selected alarm Contact output signal 3 function Sets output signal function of contact output 3. ALM Contact output signal 3 operation Sets output signal operation of contact output 3.
20 1 3 3 3 A mA mA mA Command signal Command signal Command signal VY11300 1 VY1400 1 VY1500 1 1 1 1 0.8 0.8 0.8 A port pressure (MPa) A port pressure (MPa) A port pressure (MPa) 0.6 0.6 0.6 0.4 0.4 0.4 0.2 0.2 0.2 VY130-5 VY140-5 VY150-5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 V V V VY130-6 VY140-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 2 2
Use a commercially available belt wrench etc. for mounting and removing clamp rings. 68 High Precision Filter for Liquids FGH Series Dimensions FGD FGE FGG FGA FGC FGH100/200 FGH300 FGF FGH FGH 2 x Rc 2 x Rc M6 M6 FQ1 FN EB ES Pull-out dimension Pull-out dimension Dimensions A B Element length Port size (Rc) Model 3/8, 1/2 235 FGH100 70 x L117 211 3/4, 1 240 364 3/8, 1/2 FGH200 70 x L246
Tighten the cap nut firmly by hand on the fitting. 1 2 3 Universal nipple: MS-5UN 4 Use of tube with barb fitting Caution Cut the tube perpendicularly to the tube axis to a little longer length than required length. (Use tube cutter TK-1, TK-2 or TK-3.)
(mm) D Model B d H C SNJ-015A Y M10 x 1 3 14 16.2 E SN-015A M14 x 1 5 19 21.9 SNJ-010A M8 x 1 3 12 13.9 C A B Ball joint type: 40, 50 D E Y C A B (mm) D E Y ZP10F Model B A C 1.5 6.5 10 12 ZP13F 13 15 3 8.2 2 7 ZP16F 16 18 ZP20F 20 22 8.5 ZP25F 3 25 28 4 10.2 ZP32F 9 32 35 ZP40F 5 13 40 43 10 28 ZP50F 6 14 50 53 8 13-11-101 6 Vacuum Pad: Ball Joint Type Vertical Vacuum Entry Without Buffer
Note 1) 2 1/8, 1/4 3 3/8 4 1/2 Type Metric size Inch size 2 Elbow 3 Universal Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Tubing O.D. 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Control type 0 Meter-out 1 Meter-in * Meter-out and meter-in types can be visually identified by color of the knob.
20 D 3 5 Y Hexagon width across flats 16 15 D 3 3 F Hexagon width across flats 12 Hexagon width across flats 12 Hexagon width across flats 10 Hexagon width across flats 2 F Hexagon width across flats 3 3 C C 2 2 A A B B Dimensions Dimensions (mm) (mm) A B C D F Y A B C D F Model Model ZPT10F-B5-A8 ZPT20F-B5-A10 10 12 10 12.5 37.5 20 22 1.5 12.5 15.5 48.5 ZPT13F-B5-A8 ZPT25F-B5-A10 13 15 25
A Weight (g) L1 L2 M D Q Part No.
Q H R R H Width across flats 12 Width across flats 3 F Width across flats 12 Width across flats 3 F E E D C D C 3 2 3 2 A B A B With a stroke of 10mm With a stroke of 20 to 50mm Dimensions/10mm stroke Additional dimensions by stroke (mm) (mm) Q: 6 Q: 8 H I J Stroke A B C D E F H I J Model R S R S 20 +10 3 0 ZPR20F10-0-A14 20 22 12.5 15.5 29.3 46.5 58.5 126.5 30 +20 +7 50 ZPR25F10-0-A14 25
(Use P/A tube cutter TK-1, TK-2 or TK-3.) Then push the tube in until it comes to a dead end and tighten nut by hand. 1 2 96 Series KF Insert Fittings Male connector: KFH Applicable tube (mm) A Effective orifice (mm 2) H1 (Hex.) H2 (Hex.) Thread R(PT) Weight (g) L2 M d L1 Part No. O.D.
with a warning tag. 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Body size 2 3 4 5 1/8 3/8 1/2 1 SMC Interface part is required if attached to a modular FRL.
As a rule, they should be tightened 2 to 3 turns with a tool after first tightening by hand. Be careful not to cause damage by over tightening. 1.Tube attachment and removal of One-touch fittings. 1) Installation of tube. 1. Take a tube having no flaws on its periphery, and cut it off at a right angle. When cutting the tube, use tube cutters TK-1, 2 or 3.
1 Check Valve Series AK Large flow capacity Low cracking pressure: 0.02 MPa A wide variation of models Model Model Effective area (mm2) Port size Weight (g) 1 8 AK2000-01 25 105 1 4 AK2000-02 27.5 100 1 4 AK4000-02 47 155 3 8 AK4000-03 85 150 1 2 AK4000-04 95 140 3 4 AK6000-06 200 345 AK6000-10 230 315 1 Specifications AS Fluid Air Proof pressure 1.5 MPa ASP Maximum operating pressure 1 MPa
Body size 3 4 5 6 1 Pressure gauge 8 3 ARX 1 2 None With pressure switch Nil S None Adapter assembly 4 3 1/4 3/8 1/2 3/4 1 AMR AMR Port size Thread type Thread type ARM Symbol Port size Nil N F Nil N G Rc NPT G Rc NPT G 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the port size of the body.