SMC Corporation of America
Elite Part Number Search
Search Results "AS5000-04-H"

MLU Clevis pin and knuckle pin Rod end nut ML1C D30 d Dd9 -X d 20D C l m m t t L H B Data (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 d 7.6 9.6 9.6 13.4 L 23 27 31 38 d M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 D 16.5 18 21 26 Dd9 C 19.6 21.9 25.4 31.2 B 17 19 22 27 H 6 7 8 11 Size 25 32 40 50 Part no.

CD-MU02 CD-MU03 CD-MU04 CD-MU05 d 7.6 9.6 9.6 13.4 L 23 27 31 38 d M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 D 16.5 18 21 26 Dd9 C 19.6 21.9 25.4 31.2 B 17 19 22 27 H 6 7 8 11 8 10 10 14 NT-03 NT-MU03 NT-04 NT-05 One piece is included with the rod end male thread as standard. 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 Snap ring C8 type for pivot C10 type for pivot C10 type for pivot

(example: Put on protective glass, apron, and gloves) 9.2 Specifications Ball valve Heavy duty auto drain Heavy duty auto drain assembly Heavy duty Auto drain Heavy duty auto drain ADH4000-04 Part number (Service parts) Replacement kit for exhaust valve mechanism ADH-E400 ADH4000-04 Replacement kit for exhaust valve mechanism Auto drain type Float type Auto drain valve type N.O.

K With air supply valve, Vacuum release valve Thread type Nil Rc T F NPTF G Table (1) Combination of Nozzle Diameter and Standard Supply Pressure Standard supply pressure (MPa) Nozzle diameter M (0.35) S (0.45) H (0.5) 0.5 0.7 1.0 1.3 1.5 Table (2) Lead wire with 4-wire connector P5022-6-1 (0.6 m) P5022-6-2 (3 m) 13-4-23 4 Series ZMA Model H M Standard supply pressure Nozzle diameter (mm)

Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.

133 47 61 34 52 64 (Max. 73) AVL4000-*04-*DZM 3/4 & 1 128 161 59 77 74 64 (Max. 73) AVL5000-*06 to 10 3/4 & 1 128 161 59 77 34 74 64 (Max. 73) AVL5000-*06 to 10-*DZM Soft start valve with lock out H Air direction Nil Left to Right F Port thread Body size R Right to Left Nil Rc 20 1/4 N NPT 30 3/8 F G 40 1/2 C E D 50 3/4, 1 Electric entry 1(P) 2(A) Port size Manual lockout Nil 1/4 (AVL2000

Size 26 mm Port size Symbol 03 04 Size 18 mm Size 26 mm Port size 3/8" 1/2" @1 Gasket EVVS1002-9-1H EVVS1001-9-1H Size 18 mm Size 26 mm Note) Part no. for 1 pc. of gasket @2 Tie-rod (2 pcs.)

CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

5 to 100C) For low temp. environments (30 to 60C) T Note 4) Semi-standard Type of setting L Note 5), 6) 0 1 Note 1) Basic type (Knob) Air operated type Suffix 2 Set pressure range Nil For IR1000/2000 series Port size Bracket, Name plate, Mounting on the opposite side R Note 7) 0 1 2 0.005 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa Application Size Symbol IR1000 IR2000 IR3000 01 02 03 04

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Possible to use in vacuum or under low pressures External pilot type Vacuum: Up to 101.2 kPa Low pressure: 0 to 0.2 MPa Free mounting orientation 04 4 5 1 VP3 A G 1 SY SYJ Thread type Series VP 3 port solenoid valve Rc G NPT NPTF T N F Nil VK Number of solenoids VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local

Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel

Model 6 Size: nominal size X length Number of pieces 8 12 4 6 8 10 12 TM-04 TM-06 TM-08 TM-10 TM-12 2 X 6 2.6 X 8 4 3 X 8 Tube Release Tool Series TG To remove tube in a confined space or from manifolded one-touch fittings.

IC Electroless nickel plated Dimensions VBA Caution A Model ARJ1020F-M5-04 B 10.4 C 4 D E F G H J K 21 VE 10.6 (Width across flats: 10) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.