When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring). 2. Even if a proper plier (tool for installing type C snap ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
Module A Module consists of a wireless master or a wireless slave combined with I/O units and a valve manifold. Monitor mode Monitor mode allows the user to monitor the configuration of the wireless units but not make setting changes. N NFC Abbreviation of Near Field Communication.
4 SMC 37.6 53.6 B 2 18.5 12 12 e d i s U e d i s D Stations 1 2 3 4 5 6 7 8 n One-touch fitting [3(R), 1(P) port] Applicable tubing O.D.: 10 10 Lead wire length: L0, 0.6 m L1, 1.5 m L2, 3.0 m For top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 48.8 30 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 :
center 3 position exhaust center 3 position closed center 3 position pressure center (1) 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) Note 1) Except VQZ1000 and metal seal.
OUT OUT Proper Auto Switch Mounting Positions (Stroke End) Proper Auto Switch Mounting Positions(Series CE1) Auto switch (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 41 47.5 55.5 79.5 82.5 86 D-A7lH, A80H, A73C, A80C, D-F7l, J79, F7lV, J79C 4.5 13.5 17.5 39.5 44.5 42 A B 38 44.5 52.5 76.5
A A A A A A A 32 15 19 21.5 25.5 26.5 17 15.5 18.5 Note) 40 16 20 22.5 26.5 27.5 18 16.5 19.5 50 16 20 22.5 26.5 27.5 18 16.5 19.5 63 19 23 25.5 29.5 30.5 21 19.5 22.5 80 23 27 29.5 33.5 34.5 25 23.5 26.5 100 26 30 32.5 36.5 37.5 28 26.5 29.5 Note) D-A3/A44/G39/K39 cannot be mounted on 32 cylinders. 20 Series CH2E/CH2F/CH2G/CH2H Auto Switch Specifications Auto Switch Internal Circuits Reed
MGPWM MGPWL/A MGPWM MGPWL/A MGPWM MGPWL/A MGPWM MGPWL/A MGPWM MGPWL/A MGPWM MGPWL/A 1.63 1.74 1.51 1.34 1.08 0.99 1.20 2.10 20 4.36 3.46 2.87 3.93 3.07 2.76 3.45 3.97 2.74 3.28 2.90 2.59 2.14 1.97 2.34 3.53 25 6.78 5.43 4.51 6.27 4.90 4.40 5.51 6.88 6.39 7.00 6.19 5.54 4.59 4.22 5.02 7.98 32 8.48 11.14 9.36 12.46 9.83 8.87 11.00 11.13 7.04 7.72 6.82 6.11 5.06 4.66 5.54 8.80 40 9.34 12.27
D. 9 to 11:P368010-27 View A 100 46 30 2 14 IP8000-01 (With terminal box) OUT2.Rc1/4 With plug 110 38 192 218 23.5 110 40 35 OUT1.Rc1/4 SUP.Rc1/4 2 x M8 x 1.25 depth12 (Female thread for side mounting) 43 23.5 58 38 39 11 9 39 OUT2 MPa 42 162 117 16 6.1 MPa 20 50 65 A 122 ELECTORO PNEUMATIC IP8000 P O S I T I O N E R 22.5 125 At accessory E: 110 At accessory F: 110 { } 5 150 125 12 168 8
Cushion ring Brass Replacement parts: Water resistant scraper (Part No.8) Note) Note) The scraper is held into the Rod cover with a light press fit. The scraper can be carefully pried out, and replaced with a press fit using a manual arbor press.
7 w i t q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A A' @6 #2 @8 @9 #0 !8 !9 #1 @7 !4 !
Example: Nut for JS40 2 Series JS Dimensions JS10, 16 M M U D J U F B G H C E P A Use a 4mm precision watch wrench to attach the JS10 male threads.
H E R M A N I F O L D O P T I O N S : L A T C H I N G S O L E N O I D T Y P E L A T C H I N G T Y P E V A L V E L A T C H I N G T Y P E V A L V E W I T H M A N U A L O V E R R I D E M A N I F O L D O P T I O N P A R T S A V A I L A B L E : P E R F E C T C H E C K B L O C K P E R F E C T C H E C K B L O C K W I T H V A L V E O R M A N I F O L D Courtesy of Steven Engineering, Inc. !
B A B A B A B A A A PWR 93.5 COM (35) 64.4 43.2 66 75 (40) series EX500 2 9 SI unit 4 x M4 mounting hole 8 7 6 5 4 3 2 1 n D side Stations U side C8 [3(R) EXH port] C8: 8 One-touch fitting M12 8-pin socket DIN rail clamp screw R R 0 62.5 3 3 60 1 X X 40.5 B B B B B B B B 12 12 22.2 P P 25 1 1 A A A A A A A A 18.5 7.5 9.5 (12) (7.5) M12 8-pin plug C8 [1(P) SUP port] C8: 8 One-touch fitting
single unit that actuates a cylinder and steplessly controls the applied pressure Applicable cylinders: 25 to 125.
P, R port thread type S 20 20 stations A A X port (External pilot type) M5 x 0.8 A port size Nil Rc X P R A port M5 x 0.8, C4 R port M5 M5 x 0.8 + + + + F G 1/8 C4 4 One-touch fitting A A P port X P R N NPT P port 1/8 N3 5/32" One-touch fitting 1/8 T NPTF X port (External pilot type) M5 x 0.8 R port A port M5 x 0.8, C4 Note) For more than 8 stations, supply/exhaust air to/from both sides
(Non-locking) 55.5 [62] 43.1 36.5 25.5 49 A A 19 9.5 21 (Pitch) n-Rc (PT)1/8 P=17 21 (A port) A A 19 9.5 18.5 (Pitch) n-M5 X 0.8 P=16 16 (A port) [ ] for AC Other dimensions are the same as the M5.
P, R port thread type S 20 20 stations A A X port (External pilot type) M5 x 0.8 A port size Nil Rc X P R A port M5 x 0.8, C4 R port M5 M5 x 0.8 + + + + F G 1/8 C4 4 One-touch fitting A A P port X P R N NPT P port 1/8 N3 5/32" One-touch fitting 1/8 T NPTF X port (External pilot type) M5 x 0.8 R port A port M5 x 0.8, C4 Note) For more than 8 stations, supply/exhaust air to/from both sides