Magnet: Built-in, Mounting: Through Hole, Bore Size: 25mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 15mm, Body Option: Standard, Locking Direction: Forwarding Stroke Lock, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -
Contents Bore size (mm) Seal Kit List Description Material Note No. 20 25 32 40 50 63 80 100 MGP20-B-PS MGP25-B-PS MGP32-B-PS MGP40-B-PS MGP50-B-PS MGP63-B-PS MGP80-B-PS MGP100-B-PS @4 @5 @6 @7 #5 #6 $4 $5 Piston seal NBR Set of left nos. @4, @5, @6, @7, #5, $4, $5 Rod seal NBR Gasket A NBR Gasket B NBR Set of left nos. @4, @5, @6, @7, #5, #6, $4, $5 Set of left nos. @4, @5, @6, @7, #5, $4
B port D B C G1 U G2 U If B port of Body (B) is machined, the port is plugged with Rc 1/8.
B A Through-hole (Standard) Both ends tapped style RHC Note 1) Since 12 uses a common tube for both A and B, only B is used for part no. denotation.
stroke of 25 mm or less RZQ MI W S B A CEP1 CE1 CE2 [mm] Proper Mounting Position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F ML2B D-M9 D-M9V D-F9W D-F9WV D-A79W D-A9 D-A9V C J G5-S D-A7,A80 D-F9BAL D-P5DWL Bore size (mm) CV B A B A B A B A B A B A B A MVGQ 32 27 37.5 27.5 38 24.5 35 26 36.5 30 40.5 29 39.5 40 CC 27 39 31 43 31.5 43.5 28.5 40.5 30 42
M 2 B 20 100 H N H7B 21 C D B M 2 B 20 100 H N H7B Nil Built-in magnet No Number of auto switches D With auto switch (Built-in magnet) Nil S n 2 pcs. 1 pc.
stroke 50 or larger bore size D-P5DW 40, 50, 63 B + First-stage stroke =U =U Mounted on different side in case of a full stroke of 25 mm or less B A [mm] Proper mounting position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F D-F9 D-F9V D-F9W D-F9WV D-A79W D-F7LF D-A9 D-A9V D-F9BAL D-P5DWL D-A7,A80 Bore size (mm) A B A B A B A B A B A B A B A B 32 29 39.5
Hs A B A B Proper Auto Switch Mounting Position Auto Switch Mounting Height D-A7H D-A80H D-F7 D-A7H, A80H D-A73C, A80C D-F7, F7V D-F79F, J79 D-J79C, F7W D-F7WV, J79W D-F7BAL, F7BAVL D-J79W D-F7BAL D-F79F D-F7NTL D-F7V D-A7 D-A80 D-A73C D-A80C D-J79C D-A79W D-F7WV Bore size (mm) D-A7, A80 D-A79W D-F7NTL Bore size (mm) D-J79 D-F7W D-F7BAVL Hs Hs Hs Hs Hs Hs 20 A B A B A B A B 25 20 32 25 31.5
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
Hs A 26 B A 29 B D-B54 D-K59 / G59 Auto switch Auto switch 12 approx. Hs 12 approx.
Hs A B A B 32 to 50 D-A73C D-A80C D-J79C D-A79W D-F7W D-F7V Approx. Hs Approx.
CKQ CLKQ B B B B B B A 14 49 B B A 14 49 B A 14 49 B A 7 42 A 10 45 A 11.5 46.5 A 11 46 19 or more 17 or more 33 or more 27 or more 28 or more 27 or more 22 or more 30 or more 22 or more 17 or more 54 or more 52 or more Auto Switch Mounting Height Atmosphere General use Mounting Rail mounting Rail mounting Welding Direct mounting D-A7 D-A80 D-A7H D-A80H D-F7BAL D-F7W D-J79W D-F7NTL D-F79F
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
Hs A B A B Proper Auto Switch Mounting Position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W Bore size (mm) B B A A B A B A 32 3 11 51 43 6 46 5.5 45.5 40 5.5 13.5 49.5 57.5 8.5 52.5 8 52 50 19 11 53.5 61.5 14 56.5 13.5 56 63 22 14 59 67 17 62 16.5 61.5 Auto Switch Mounting Height (mm) D-A7H, A80H D-F7, J79, F7W D-J79W
C D Side support B MY-SB 2 x J 2 x H C D A B A B C D E F G H J Applicable cylinder MY1W16 MY1W20 MY1W25 MY1W32 MY1W40 MY1W50 MY1W63 Model MY-S16A 61 71.6 15 26 4.9 3 6.5 3.4 M4 x 0.7 B MY-S20A 67 79.6 25 38 6.4 4 8 4.5 M5 x 0.8 B MY-S25A 81 95 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 100 118 45 64 11.7 6 11 6.6 M8 x 1.25 B 120 142 MY-S40A M10 x 1.5 55 80 14.8 8.5 14 9 B 142 164 MY-S63A 172 202
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5