SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2B40-200-P"

25 Tubing T, TU P. 26 Floating Joint/Stainless Steel Type JS P. 27 Features 2 Stainless Steel Cylinder Series CJ5-S 10, 16 How to Order Bore size Standard stroke (mm) 10 16 10 16 10mm 16mm 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting Basic type Axial foot type Front flange type Double clevis type B L F D CJ5 L 16 S R 60 Without Auto Switch CDJ5 L

1 y, z + A = 200 y, z + A = 300 1 y, z + A = 200 0.1 y, z + A = 300 0.01 0.1 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the

20 20 stations Rc 1/4 Built-in One-touch fittings Applicable tubing O.D. 6 C6 Manifold specifications/Single base type B mount (P/E port size) Built-in One-touch fittings Applicable tubing O.D. 8 C8 Applicable valve model Piping P, E port Port size Symbol VV3Z4-S50: only C6 & C8.

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

H1 Width across flats B1 D I RE A B AL A MM Width across flats NA K REC C0.1 8-J 4-FD M S + Stroke ZZ + Stroke H FX0.15 B CX CY Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 MQQ M Up to 200 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 1/8 83 124 25 Up to 300 22 19.5 17 50 18.5 10 36 5.5 6 18 12 40 6 33 M5 x 0.8 5.5 8 3.5

H1 Width across flats B1 D I RE A B AL A MM Width across flats NA K REC C0.1 8-J 4-FD M S + Stroke ZZ + Stroke H FX0.15 B CX CY Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 MQQ M Up to 200 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 1/8 83 124 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

For the function, refer to P.5-29,P.5-30 [Temperature range monitoring function setting example]. Temperature range monitor start time HRR Series 5.5 Advanced setting mode 5-31 HRX-OM-X071 Chapter 5 Display and Setting of Various Functions 24. Press the [] key.

(The lock-up cylinder can operate at 50 to 200 mm/s.)

For transfer load of 1kg Positioning time (sec) Positioning distance (mm) 100 200 50 10 1 50 2.1 4.1 1.1 0.3 0.1 Speed (mm/s) 100 1.1 2.1 0.6 0.2 0.1 200 0.6 1.1 0.3 0.1 0.1 Refer to page 302 for acceleration time. 249 Series LXP CE Marking Guide Rod Type With Motor Brake/Without Motor Brake How to Order LX P B 2 S 1 S B 100 F9N Q B CE marking Guide rod type P Actuator configuration Number

E C I A L R O D T H R E A D X A O P T I O N Thread Form Code M .

Alarm Sequence Setting range : On, Off Indicated content : Use of temp. upper/lower limit alarm U p p e r / L o w e r T e m p . A l a r m S e q u e n c e M O D E < O f f sequence(Ex. : Off) Function : Determines whether or not temp. upper/lower limit alarm is output when power is turned on.

E C I A L R O D T H R E A D X A O P T I O N Thread Form Code M .

0.5 (With indicator light: 0.55) (A) 2 0.9 (With indicator light: 1.0) 100 V 110 V [115 V] 1.0 (With indicator light: 1.1) [1.1 (With indicator light: 1.2)] 3 (R) 1 (P) 1 (R) 3 (P) Apparent power (VA) AC 1.8 (With indicator light: 1.9) 200 V 1.9 (With indicator light: 2.0) [2.2 (With indicator light: 2.3)] 220 V [230 V] Made to Order Specifications (For details, refer to page 4-3-17.)

With manually operated handle Proximity switch T TURCK P P&F W None * Switch cassette viewed from the front.

Note 1) ( ): Long stroke Note 2) Refer to p.1.6-11 for pivot bracket.

Tube bore size B, #2(#2+#3) 40 125, 150, 175, 200, 250, 300 55 14 14 3.8-9 Series CXT Auto Switch Specifications Refer to p.5.3-2 for details on auto switch.

VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability

No IC circuit P P Y59A Y69A 3 wire (NPN) IC circuit p P P 5V, 12V P.9 Y7P Y7PV IC circuit 3 wire (PNP) p P P Y59B Y69B 12V 2 wire p P P Relay, PLC Solid state switch 24V Y7NW Y7NWV 3 wire (NPN) Grommet Diagnostic indication (2 color indicator) Yes p P P 5V , 12V IC circuit Y7PW Y7PWV P.10 3 wire (PNP) p P P Y7BW Y7BWV 12V p 2 wire P P Lead wire length symbols: 0.5m .