Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 660, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
73 psi [0.5 MPa] Peak clamping force position 112 [500] 90 [400] 0.3 MPa 44 psi [0.3 MPa] 67 [300] 45 [200] 22.5 [100] 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Shim thickness [mm] 9 CKZT -X2797 -X2798 Be sure to read this before handling the products.
200 500 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min (ANR)] IW215 Flow rate characteristics IW222 Flow rate characteristics Supply pressure: 0.7 MPa 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 100 300 400 200 600 500 Supply pressure: 0.5 MPa 0.25 0.2 Set pressure [MPa] Set pressure [MPa] 0.15 0.1 IP 0.05 IW IW 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate
Signal contents 1 24 VDC + Operating environment Ambient temperature: 0 to 40C, Humidity: 20 to 80%RH, (no condensation) L 100-240 VAC 2 24 VDC 1 2 E PE DC output connection Thermo-con (HEF002-A6, INR-244-831) N E Not for use with other products The power supply cable can only be used for the applicable models shown below. Do not use it for other products.
The positioning time can be set in increments of 0.001 seconds). e) Speed Set the speed required for the uniform movement phase to reach the [Target position]. The setting range is 1 to 400 mm/s. The speed can be entered when the [Speed Entry Method] has been selected in the [Step Data Input Method] in the Basic Parameter Set up window.
6 @3 @4 e !7 w i t q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A A' @6 #2 @8 @9 #0 !8 !9 #1 @7 !4 !
Ventilation (H/X inlet) Ball tap Expansion TS E Circulating fluid return port valve A Level switch Expansion Fluid level gauge valve B Customer's E machine Temp. sensor (Ref. discharge (Heat load) Press. sensor (Outlet) TS PS TS Heat Temp. sensor Circulating fluid outlet port exchanger (Outlet) Press. sensor (Ref. low press.)
Consider q Max. payload, w static moment, e dynamic moment (when stopper collides) when calculating the Max. allowable moment and payload. Evaluate q and w as a (average speed), and e as (collision speed =1.4a). Calculate q (Wmax) from the graph of Max. payload (W1, W2, W3) and calculate w and e (Mmax) from the graph of Max. allowable moment.
16 59 63 End lock mechanism dimensions MGPL (ball bushing)/A, DB, E dimensions (mm) (mm) E A HN (Max.)