Search Results "CDLSB200-250"

direction Maximum operating pressure Unlocking port size 50 Spring locking (exhaust locking) 0.2MPa or more (29 psi) 0.05MPa or less (72 psi) One direction (extension locking, retraction locking) 1.0MPa (145 psi) Rc 1/8 40 63 Holding force N (lbf) (maximum static load) 982 (220) 629 (141) 1559 (350) Standard Strokes Bore size (mm) Standard stroke (mm) 25, 50, 75, 100, 125, 150, 175, 200, 250

Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.

HOW TO ORDER NVFil 250 -N02 02 S v"lrrs..i"" Tt L Rolter Material (01, 02, O6) : Acetal (Standard) NVFM 250(1) Cy1.0 NVZM 450(1) Cy0.55 S : Steel Pilot Supply 0 : Internal Pilot From "P" Port 1 = External Pilot Supply (Special Order Only) 00 : lhlve Body Only 0l = StandardCam Lever 02 = Cam Lever-One Way 05 = Plunger 06 = Roller Plunger, Inline 08 = Toggle Lever 30 = Push Button-Mushroom'

Multistage Ejector (N)ZL112 with Valve and (N)ZL212 Large Flow Type (N)ZL Series 3 Stage Construction Optional Supply & Release Valves Optional Pressure Sensors Series (N)ZL Multistage Ejector Energy saving, high flow, 3 stage diffuser construction Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, single stage model) 1 stage

rail 43.1 29.5 (5.25) (Voltage rating indication) L2 (DIN rail mounting hole pitch 12.5) L1 P=19 51 [Rc(PT) 1/4 port] 2n2-One-touch fitting Applicable tube O.D.: 8 10 SS5Y7-60Stations D [52.5] (5.5) (Light/surge voltage suppressor) (Station n) (Station 1) 25.4 39 49.1 (5.4) 2 3 4 5 6 7 8 9 10 Stations L1 135.5 148 173 185.5 210.5 223 248 260.5 285.5 L2 125 137.5 162.5 175 200 212.5 237.5 250

n: Stations (max. 16 stations) L n 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 191.5 231 262.5 273 16 L1 L2 (L3 ) (L4 ) 26.5 66 87.5 98 37.5 77 100 110.5 48.5 88 112.5 123 59.5 99 125 135.5 70.5 110 137.5 148 81.5 121 150 160.5 92.5 132 162.5 173 103.5 143 162.5 173 114.5 154 175 185.5 125.5 165 187.5 198 136.5 176 200 210.5 147.5 187 212.5 223 158.5 198 225 235.5 169.5 209 237.5 248 180.5 220 250

kbps 0 1 1 2 500 kbps 0 2 2 3 : : : : PGM 6 2 62 9 6 3 63 6 4 : : PGM 9 DeviceNetPGMHW/SW ON -21No.EX-OMN0029CN-D V_SEL SI () Settings1 SI 1 2 OFF OFF 32 4 byte() OFF ON 24 3 byte ON OFF 16 2 byte ON ON 8 1 byte Baud Rate EX600 Settings1 3 4 OFF OFF 1 Mbps() OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps 1 Mbps() -22No.EX-OMN0029CN-D Settings2 1 2 OFF OFF 0 () 0 byte OFF ON

(Removal procedure and ) Applicable message I/O message size Input: Max. 8 byte, Output: Max. 8 byte (Changeable by switch settings) 1 2 Baud rate 125 kbps 250 kbps 500 kbps 500 m or less Thick cable 250 m or less 100 m or less Max. length of Network 3 4 Thin cable 100 m or less 156 m or less 78 m or less 39 m or less Total extended cable length Note: Max. extended cable length is 6 m. 11

number. *2: Select a protocol before performing pairing (V.2.0: 1 Mbps, V.1.0: 250 kbps).

Station L1 L2 2 110 3 145 36 4 180 71 5 215 106 6 250 141 Unit Manifold With DIN rail Deflection level indicator Terminal block box 35 40 L1 Deflection level indicator 75 40 Terminal block box Rc1/8 SUP. 25 DIN rail center 70 (94.4) 90 25 (94.4) SUP 70 4.5 90 40 (4.5) 30 4.5 Adjusting knob Gauge Electrical entry Applicable O.D. 6.5 to 8.5 12 L2 L3 Gauge 105 Electrical entry Applicable O.D

These default values can be changed in the Offset FB Overall Accuracy +/5% (0.5V DC) Input Impedance 150 kOhm or higher Input Voltage 0 10V DC Conversion Speed 10 ms Resolution 10/250 mv Analog Input Range 0 250 ECC-PNAL-20M*-D 8 Channels: I01 I08 ECC-PNAL-10M*-D 6 Channels: I01 I06 Description Analog Input Specication 7 2.4 Output Specication PneuAlpha Hardware Specification 2 Table 2.7

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure

Note) If the set pressure is 250 kPa and the output pressure on the pressure sensor is 245 kPa, the deviation is 250 245 = 5 kPa. In order to correct the deviation, the controller increases the output signal until the pressure on the pressure sensor converges at 250 kPa. Step 1 Step 2 Step 3 Step 4 . . . . . . . . . . . . .

ZSE4 ISE4 ZSE5 ISE5 Detection nozzle: 1.0 Piping: 6 X 4 tubing Supply pressure: 0.1MPa Detection distance: 100m ZSE6 ISE6 Detection nozzle: 1.0 Piping: 6 X 4 tubing 5m Supply pressure: 0.2MPa ZSE3 ISE3 4.0 2.5 Set value 50m 300m 100m 200m GS 2.0 3.5 PS Response time (sec) 1.5 3.0 ISA 1.0 2.5 ZSE1 ISE1 Response time (sec) Piping length 0.5 ZSE2 ISE2 2.0 10m 8m ZSP 50 150 0 1.5 100 200 250

Stations L1 L2 3 74 56 6 122 104 8 154 136 10 186 168 20 346 328 2 58 40 4 90 72 5 106 88 7 138 120 9 170 152 11 202 184 12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 1.2-45 Series SYJ5000 40 Type Manifold: Bottom Ported/SS5YJ5-40Station -M5 Grommet (G), (H) (Lead wire length) G: 300 H: 600 4-4.5 (Mounting holes) 13 (Pitch) P=16 21 103.2 (GZ, GS

1 EJECTOR MULTISTAGE Multistage Ejector Series ZL112/212 Energy-saving, large flow rate, 3 stage diffuser construction ZX Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage perf stage perfor ormance mance 1 stage performance Vacuum pressure ZR Q1 Q2 Q3 ZM Q1 Q2 Q3 Maximum suction flow rate (l/min (ANR))