*Refer to the table of Applicable stroke 6mm 6mm 8mm 8mm 10mm 10mm B B Cable type *Applicable stroke Standard produced upon receipt of order Without cable Nil Without cable Nil 100 100 200 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 Robotic type cable R Robotic type cable R 11-LEFS25 11-LEFS25 Standard cable S Standard cable S 11-LEFS32 11-LEFS32 Motor cable
30 37 47.3 d M6 x 1.0 M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 Part no.
t o o g e a n L c 2 s u s d Particulate generation has been reduced at the stroke ends by reducing impact using a sine cushion and by stopping the stroke using an internal stopper. i e Reduction of outgassing due to surface treatment n Impact acceleration [m/s2] o u d t R g g e a c 1 s u s d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless
BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.
BBA1: D-A5/A6/F5/J5 types *"D-F5BAL" switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, "BBA1" screws are attached.
Max. 16 stations C3, C4, C6, M5 C6 VQ1000 Side D-sub Connector (25 pins) D side U side Stations 1 2 3 Cable assembly 015 030 050 AXT100-DS25Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Wire Color by Terminal No. of D-sub Connector Cable Assembly The D-sub connector
Example) D-F9NL Main switch circuit Main switch circuit Output Black [White] () Blue [Black] D-F9P (+) Brown [Red] Auto Switch Dimensions (mm) 1in=25.4mm Output Black [White] D-F9N, D-F9P, D-F9B () Blue [Black] D-F9B (+) Brown [Red] L dimension (mm) Part No.
Proper auto switch mounting position A B Auto switch model D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 Cylinder model CYP15 93.5 24.5 CYP32 122 33 Auto Switch Mounting When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.
Switches / Direct Mount Type D-Y7NW (V)/Y7PW (V)/D-Y7BW (V) Auto Switch Specifications D-Y7mW, D-Y7mWV (with indicator light) D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV Auto switch part no.
Switches / Direct Mount Type D-Y7NW (V)/Y7PW (V)/D-Y7BW (V) Auto Switch Specifications D-Y7mW, D-Y7mWV (with indicator light) D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV Auto switch part no.
Dimensions for Mounting of Auto Switch D-Z7/Z8 (Reed switch) D-Y5, D-Y6, D-Y7 (Solid state switch) A Dimension Bore size (mm) Auto switch model 10 15 20 25 32 6 A D-Y59A/Y7P/Y59B D-Y69A/Y7PV/Y69B D-Y7NWV/Y7PWV/Y7BWV D-Y7NW/Y7PW/Y7BW D-Y7BAL D-Z7, D-Z8 0.2 0.7 6.0 0.7 6.5 1.2 Mounting of Auto Switch When mounting and securing auto switches, they should be inserted into the cylinders switch
(same side) D-Z73, Z76, Z80 Reed switch 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 60 D-Y59A(B), Y69A(B) Y7P(V) 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 70 D-Y7NW(V), Y7PW(V) Y7BW(V) Solid state switch 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
width across flats) AS-D AS-T ASP ASN AQ ASV AK Metric Size Inch Size VCHC Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.
SD0 SDA1 SDA2 Serial kit without SI unit Serial kit for Remote I/O 1 to 8 stations (16 stations) FD0 FD1 FD2 FD3 D-sub connector kit (25P) without cable Serial unit: EX126 D-sub connector kit (25P) with 1.5 m cable 1 to 12 stations (24 stations) Serial kit for DeviceNet/PROFIBUS-DP/CC-LINK D-sub connector kit (25P) with 3.0 m cable P SDVB Serial kit for CC-LINK 1 to 8 stations (16 stations
for AC, since a rectifier prevents surge voltage generation. 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz)[115 VAC (50/60 Hz)] 4 220 VAC (50/60 Hz)[230 VAC (50/60 Hz)] 5 24 VDC 6 12 VDC Electrical entry D DIN terminal (Type D) With connector DO Without connector * DC specification of type D and DO is only available with 12 and 24 VDC.
CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32
/M5W/M5TL D-E7A/E80A D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
/M5W/M5TL D-E7A/E80A 25 6 4 32 6 4 D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
Range (mm) No. of auto switches mounted Applicable auto switch Bore size (mm) 25 6 4 D-M5, D-M5W, D-M5T D-E7A, D-E80A Auto switch model 40 6 4 D-M5, M5W, M5T D-E7A, E80A 32 6 4 10 15 5 10 1 pc. 2 pcs.
Dimensions (mm) A B C D E F G K L M N P Model IDFA100F IDFA125F Port size R2 670 460 335 107 700 1120 1276 267 1375 20 712 752 R2 1/2 700 655 350 78 935 IDFA150F E D B 10 note) A G F C N M L K Note) In addition to the overall length of the body, the filter mounting part (bracket) projects 10 mm.