N T, F, N are order made specifications.
R L B 01 1 Nil F G Rc 1 8 ... ...
Piping thread type : When F is selected, G thread adapter set will be added.
Port thread GB Width across flats B1 H1 C NA C NA D E E AL A H S + Stroke ZZ + Stroke F NA C NA C MM 4 x JA 4 x JB Female thread MM Depth A1 H ZZ + Stroke Female rod end Female Rod End [mm] [mm] Bore size A AL B1 C D E F H H1 JA JB KA MM NA Bore size A1 H MM 20 14.5 12 13 15.5 8 14 0 0.1 2 21 5 M4 x 0.7 depth 7 M4 x 0.7 depth 5.5 Width across flats 6 length 3.5 M8 x 1.25 24 20 8 6.5 M4 x
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact P/A regarding other voltages.
type C (H1) (H2) 60 A B E C (H1) (H2) 2-P B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SMC A B E L J B 2-P 2-F K Body material: PFA N G A D L K 4-M Non-locking type Locking type 60 C (H1) (H2) A B SMC E J B 2-P (mm) Dimensions A B C D E F G H1 H2 J K L M N P
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact SMC regarding other voltages.
F F1 628 < 686 (max.) CEP1 3. Specifications and operational instructions Ensure that the collision speed, thrust, operation cycle, the ambient temperature and atmosphere fall within the specifications. Be aware of the min. installation radius in the case of rotating impacts.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Voltage 2 2 4 4 15 10 250 VAC 1.5 1.5 3 3 15 10 8 VDC 1.5 2.5 3 5 15 15 14 VDC 1.5 2.5 3 5 15 10 30 VDC 1.5 2.5 3 5 6 5 125 VDC 0.3 0.05 0.3 0.05 0.5 0.05 250 VDC 0.2 0.03 0.2 0.03 0.25 125 VAC 15 15 15 15 6 0.5 0.25
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250
, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
EX600-DYB EX600-DYE/F EX600-DME/F EX600-AXA EX600-AYA EX600-AMB -54No.EX-OMN0029CN-D TM RSNetWorx for DeviceNet EX600 Rockwell Automation DeviceNet RSNetWorx for DeviceNet TM TM version 5.00.00 RSNetWorx for DeviceNet EDS TM (1)RSNetWorx for DeviceNet (2)[Tools][EDS Wizard] (3)EDS (2) TM\Vendor\SMC Corporation\Communication Adapter (4)[Hardware ]DeviceNet EX600-SDN DeviceNet TM\Category
Cable with M12 connector (8 pins/Both angle) Cable with connector For output entry D EX9-AC-7 Cable with M12 connector (Plug/A-coded) Terminal plug For EX500 C EX500-AC000-S Terminal plug (M12/8 pins) Seal cap For plug E EX500-AWTP Seal cap (M12/For plug) EX9-AWES Seal cap (M8/For socket) EX9-AWTS Seal cap (M12/For socket) Power supply cable For connecting the SI unit to the power block F
Additional weight 0.23/50 stroke Stroke 100 stroke 0.46 + 100 / 50 X 0.23 = 0.92kg Standard Stroke (mm) Size Standard stroke Max. stroke(mm) 25, 32, 40 50, 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250, 300 300 Contact SMC for any intermediate strokes that are not indicated above, as they will be produced upon receipt of order.
Note) If the set pressure is 250 kPa and the output pressure on the pressure sensor is 245 kPa, the deviation is 250 245 = 5 kPa. In order to correct the deviation, the controller increases the output signal until the pressure on the pressure sensor converges at 250 kPa. Step 1 Step 2 Step 3 Step 4 . . . . . . . . . . . . .
If the variable orifice is closed (turn the adjustment knob counterclockwise), all LED's are off. d When opening the variable orifice (turn the adjustment knob clockwise) the LED's will light up in the following order: Red 1, Red 2, Green 1, Green 2 f When the LED Green 1 is on, the output is energized.
"R" and "U" types are available for DC voltage valves. : Without bracket F : With bracket Rated voltage For AC (50/60Hz) For DC 5 6 V S R 1 2 3 4 24V DC 12V DC 6V DC 5V DC 3V DC 100V AC 200V AC 110V AC [115V AC] 220V AC [230V AC] A, B port size M5 C4 C6 M5 X 0.8 4 One-touch fitting 6 One-touch fitting Note) The double solenoid mounting bracket is supplied unattached.
1 EJECTOR MULTISTAGE Multistage Ejector Series ZL112/212 Energy-saving, large flow rate, 3 stage diffuser construction ZX Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage perf stage perfor ormance mance 1 stage performance Vacuum pressure ZR Q1 Q2 Q3 ZM Q1 Q2 Q3 Maximum suction flow rate (l/min (ANR))