Cooling Capacity: 300 (28 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)]
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)]
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: B + T
Cooling Capacity: Cooling Capacity: 3800W/4200W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + T
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With earth leakage circuit breaker / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / High pump head specification
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BT (B + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BT (B + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BT (B + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BT (B + T)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BT (B + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)
Cooling Capacity: 040 (Cooling Capacity: 3800W/4200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BT (B + T)
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
This product is obsolete. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER (PROPRTY JDSU), OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0181700/1900 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz)