Outside of clean room Duct piping Series 11-/13-/22(Vacuum suction type) With a vacuum pump When several air cylinders are used together or a model with high vacuum suction flow is used. With an ejector When a few air cylinders are locally used.
Bore size (mm) B A A B 90.5 29.5 39.5 80.5 90.5 10 to 50 75, 100 39.5 40 Rod end nut 38.5 Rear flange type: CLQG40 54 40 4-5.5 A + Stroke 8 7 B + Stroke 34 72 62 Rear flange type (mm) Stroke range Without auto switch With auto switch Bore size (mm) A B A B Rod end nut 28.5 88.5 29.5 39.5 78.5 88.5 10 to 50 75, 100 39.5 40 Double clevis type: CLQD40 4-M5 x 0.8 Cap bolt 10 hole H10 Shaft d9
4.5 7 6 8 10 14.5 A 15.5 24 24 26 29 32.5 B 9.5 12 11 13 15 19.5 A 16 16 18 21 24.5 B 4 3 5 7 11.5 A 12.5 12.5 14.5 17.5 21 B 0.5 0 1.5 3.5 8 A 16.5 16.5 18.5 21.5 25 B 4.5 3.5 5.5 7.5 12 32 40 50 63 80 100 32 40 50 63 80 100 Note 1) D-M9, M9V, M9W, M9WV, M9A, M9AV cannot be mounted to 100.
Required ventilation rate [m3/min] Model Heat radiation amount [kW] Differential temp. of 3C between inside Differential temp. of 6C between inside and outside of installation area HRR010-A Approx. 2 40 20 HRR012-A Approx. 2 40 20 HRR018-A Approx. 4 70 40 HRR024-A Approx. 5 90 50 HRR030-A Approx. 6 100 60 HRR050-A Approx. 10 140 70 and outside of installation area Voltage dV dt = Voltage
Example) For 10-CQ2XB40-57D, a 18mm width spacer is installed in a standard stroke 10-CQ2XB40-75D cylinder. 12, 16 20 25 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32, 40 Refer to "How to Order" on page 7 for auto switch model numbers.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8. Cautions for use in an interlock circuit.
(mm) 40 50/63 80 100 E1 L1 MM U1 NDH10 NX A1 MM E1 L1 U1 NZ L NX Part No. A R1 Part No.
Dimensions (mm) 1in=25.4mm (b) C D E C E E (a) F (c) Heater (optional) B G A A (mm) D 1 1 2 2 C 38 48 66 79 B 100.5 114 162.5 179.5 F 30 40 55 75 A 40 50 65 70 G 17 26 41 52 E Note 1) Model XLH-16 XLH-25 XLH-40 XLH-50 12 11 11 Note 1) Dimension E applies when heater option is included.
(mm) Auto switch model Bore size (mm) 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V) Auto switch model Bore size 20 25 32 40 D-A9l(V) 6 6 6 6 BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9l(V) D-M9lW(V) D-M9lA(V) 3 3 4 3.5 D-M9lA(V) Note 2) BM5-020S (A set of b, c, d, e) BM5-025S (A set of b, c, d, e) BM5-032S (A set of
A voltage drop may cause the air dryer to stop operating. *1 Select an earth leakage breaker with a sensitivity of leak current of 30 mA and a rated current of 10 A. <200 VAC> Connect the power supply to the terminal block. Install an earth leakage breaker*2 suitable to each model for the power supply.
Select an option symbol by the "Applicable Fluid Check List" p.4.0-7 for a special fluid outside of standard.
Bore size Cylinder stroke (mm) 12 16 20 25 32 40 50 63 80 100 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm Built-in Magnet Cylinder Model 12, 16 20, 25 32, 40 50 to 100 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 If a built-in magnet cylinder without an auto switch is
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
Intermediate stopping of load with an external stopper, etc. When stopping a load in mid-stroke using an external stopper (adjusting bolt, etc.), operate within the operating pressure limits shown in the table below. Use caution, as operation at a pressure exceeding these limits can result in breaking of the magnetic coupling.
40 mA) 100 A or less at 24 V DC Leakage current 0.8 mA or less Indicator light Red LED illuminates when turned ON.
Heater: 422 A XLC/XLCV Series Aluminum High Vacuum Angle Valve Dimensions XLC16, 25, 40/ Air operated (b) E C D E C E Fn (KF flange) (a) Heater (Option) (c) Auto switch (Option) H J B G A A (mm) J A B C D E Note 1) Fn G H Model XLC-16 XLC-25 XLC-40 40 110 38 1 30 17 40 26 50 121 48 1 12 40 26 39 28 65 171 66 2 11 55 41 63 36 Note 1) Dimension E applies when heater option is included.
Never use them in the presence of an explosive gas, as this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized. (Please consult with SMC regarding the availability of a magnetic field resistant auto switch.) 3.
CAT.ES20-147 A Compact Rotary Actuator Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Compact Rotary Actuator Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Piping can be installed from one end Body can be used as a flange Compact design saves mounting space Uses internal cushioning 10, 15 : Rubber bumper 20, 30, 40: Air cushion 10: 17mm 15: 20mm 20: 29mm 30: 33mm
Note 7) A reference value for correcting an error in reciprocal operation. Note 8) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw. (Test was performed with the actuator in the initial state.)
32 272 178 36 Stroke B Stroke A S + Stroke (A + B) ZZ + Stroke (A + B) 40 280 178 38 50 314 198 41 63 314 198 43 80 386 242 52 ZZ S Q L GC Bore size (mm) 100 386 242 52 40 282 180 66 12 42 GC 50 310 194 74 14 48 Stroke B Stroke A Series MB1 63 326 210 76 14 48 S + Stroke (A + B) 80 390 248 90 16 58 ZZ + Stroke (A + B) 100 414 270 98 18 60 Stroke B Stroke A ZZ + Stroke (A + B) S + Stroke