Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: -, Adapter: -, Calibration Certification: -
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: -, Calibration Certification: -
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -
Piping Specifications: R1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: -, Adapter: -, Calibration Certification: -
Place them in alphanumerical order. q e w Switch Characteristics Description Symbol Example) IS10-N01-6PZ Nil N Rc NPT q q Thread type Max. contact capacity AC 2 A, DC 2 W 24 V or less Note 1) Set pressure range of 6P(L, Z) is 0.2 to 0.6 MPa (30 to 90 psi). This product is for overseas use only according to the new Measurement Law.
Maintenance Bracket A or D(Model: ZS-24-A/ZS-24-D) Bracket B (Model: ZS-24-B) [01/N01 type] [W1/WF1 type] Operator How to reset the product after power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing.
/O.D. mm Symbol Symbol Symbol 01 02 03 04 N01 N02 N03 N04 07 09 11 13 06 08 10 12 07 09 11 13 6 8 10 12 1/4" 5/16" 3/8" 1/2" R, Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose.
1/4 NPT1/8 PH1/4-N01 $1.80 O.D.Tube Thread ITEM NO: PRICE 1/4 NPT1/4 PH1/4-N02 $2.04 (inch ) (UNF&NPT) USD/PCS 1/4 NPT3/8 PH1/4-N03 $2.25 1/8 10-32UNF PH1/8-U10 $1.50 5/16 NPT1/8 PH5/16-N01 $1.77 1/8 NPT1/8 PH1/8-N01 $1.50 5/16 NPT1/4 PH5/16-N02 $2.04 1/8 NPT1/4 PH1/8-N02 $1.50 5/16 NPT3/8 PH5/16-N03 $2.25 5/32 10-32UNF PH5/32-U10 $1.50 3/8 NPT1/8 PH3/8-N01 $2.04 5/32 NPT1/8 PH5/32-N01 $1.50
-01ST 20.4 27.5 1/8" 8.4 4 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 14.2 7 35.6 11.6 R 1/8 12 1.5 13.5 6 32 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT1/8 12.7 14.2 7 35.6 1.5 32 15.2 25.3 18.5 32.4 8 AS221F-N01-07ST AS221F-01-10ST 15 1/4" 13.2 23.9 31 18.5 18.5 21 33.1 40.2 10 AS221F-N01-09ST AS221F-02-04ST 5/16" 15.2 25.3 32.4 15 21 10.4 16
Actuation: 3A (Air Operated), Thread: N01 (1/8 Port, NPT Thread), Option: C (w Bracket), Made to Order: X47 (w/Bracket, Interchangeable w/Previous Type)
Actuation: 3A (Air Operated), Thread: N01 (1/8 Port, NPT Thread), Option: C (w Bracket), Made to Order: X16 (Liquid Contact Seals SF7000)
C to F in Best Pneumatics (5)(P.2 to 3). (Install a filter with filtration accuracy of 5m. If necessary, install a mist separator with the filter.) 3. Supply air which has been dried by an air dryer. (Recommended atmospheric dew point is -10oC or less.) 4.
How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage)
Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: K (w/Certificate
Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]