L D-A73 (Example) MRQ Lead wire length D5 m None Nil L 0.5 m 3 m Z N 20Applicable for the connector type (D-C) only.
L D-A73 (Example) MHY Lead wire length MHW 5 m None Nil L 0.5 m 3 m Z N MRHQ Applicable for the connector type (D-C) only.
L D-A73 (Example) MHY Lead wire length MHW 5 m None Nil L 0.5 m 3 m Z N MRHQ Applicable for the connector type (D-C) only.
Lead wire length symbols: 0.5 m 1 m 3 m 5 m Nil M L Z (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 597 for details. For details about auto switches with pre-wired connector, refer to pages 1328 and 1329. Auto switches are shipped together (not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Since there are applicable auto switches other than listed, refer to page 326 for details. For details about auto switches with pre-wired connector, refer to pages 474 and 475. D-A9, M9, M9W, M9A are shipped together (but not assembled).
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked "" are produced upon receipt of order.
If the cable length exceeds 1 m, the speed / pushing force will decrease by a maximum of 10% per 2m. (If the cable length is 5 m: Maximum 20% reduction.) Transportation Caution (1) Do not pull the cable or drag the product when transporting. 28 - 6. Troubleshooting Refer to the table below for troubleshooting.
M 3 m L 5 m Z None N Solid state auto switches marked with are produced upon receipt of order.
Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.
display unit Note 1) switching function Nil Without lead wire B Fixed SI unit Note 2) M Nil With display unit Note 1) switching function (Initial value psi) P Lead wire with connector (Lead wire length 2 m) Note) Made to Order Note 1) Under the New Measurement Law, sales of switches with the unit switching function have not been allowed for use in Japan.
Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z Auto Switch Mounting Bracket Part No.
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation Manual
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: Operation Manual,
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No. PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.
Note Weight Lead wire and M12 connector LFE-1-A3 Lead wire length 3 m Approx. 175 g Option Part no. Note Weight Bracket LFE-1-D Tapping screw for LFE1 (3 x 10), 4 pcs. Approx. 45 g LFE-2-D Tapping screw for LFE2 (3 x 10), 4 pcs. Approx. 70 g LFE-3-D Tapping screw for LFE3 (3 x 10), 4 pcs. Approx. 70 g 3
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)