Pr.1 Setting value Set value set by PLC program (Unit) 0:mm 1 to 20(x10-2mm/min) 1:inch 1 to 20(x10-3inch/min) 2:degree 1 to 20(x10-3degree/min) (Note 1) 3:PLS 1 to 50(PLS/s) (Note 1) The command speed range is 1 to 20(x10-3degree/min), but it will changed to 1 to 20(x10-2degree/min) by setting Pr.83 Speed control 10 x multiplier setting for degree axis" to valid. -60- Pr.9 Acceleration time
X10 STATION NO . X1 5 4 6 5 4 6 3.2.3 3 3 7 7 2 2 1 0 9 8 1 0 9 8 SW1 SW 1 3.2.5 (CNP1) 4.1 4.3 12.1 CC-Link L.
1 u u x100 x10 x1 IP address setting switches Switch to set the 4th byte of the IP address by X1, X10 and X100. !7 i !2 i MS, NS Communication status LED Displays the status of the EtherNet/IPTM communication t o ENC z Encoder connector (16 pins) Axis 1: Connect the actuator cable. !0 MOT z Motor power connector (6 pins) !8 @1 !
1 u u x100 x10 x1 IP address setting switches Switch to set the 4th byte of the IP address by X1, X10 and X100. !7 i !2 i MS, NS Communication status LED Displays the status of the EtherNet/IPTM communication t o ENC z Encoder connector (16 pins) Axis 1: Connect the actuator cable. !0 MOT z Motor power connector (6 pins) !8 @1 !
(X10)=0STATION No. (X1) =1) 2 : LECPMJ(2)CC-Link =3LECPMJ(1)CC-Link =1 2 (STATION No. (X10)=0STATION No. (X1) =3) 3 : LECPMJ(3)CC-Link =5LECPMJ(2CC-Link =3 2 (STATION No. (X10)=0STATION No. (X1) =5) 17 - 4.2 LECPMJ () () 1() 1 () 1 (1 ) 2 () (2 ) 4 (4 ) 9.
Pr.1 Setting value Set value set by PLC program (Unit) 0:mm 1 to 20(x10-2mm/min) 1:inch 1 to 20(x10-3inch/min) 2:degree 1 to 20(x10-3degree/min) (Note 1) 3:PLS 1 to 50(PLS/s) (Note 1) The command speed range by setting Pr.83 Speed control 10 x multiplier setting for degree axis" to valid: 1 to 20(x10-2degree/min). -64- Pr.9 Acceleration time 0, Pr.10 Deceleration time 0 Pr.9 Acceleration
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: Power supply cable included (3 m) / with bracket, I/O specifications: None, Connector options: -, Model: Standard type, Bar length(mm): 1,840
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: Power supply cable included (3 m) / with bracket, I/O specifications: None, Connector options: -, Model: Standard type, Bar length(mm): 1,960
Type: Bar Type, Indicator: Not Provided, Additional Function: Error Signal Output, Ion Balance: ±30V, Ion Balance Adjusting Function: Automatic, Operating Pressure Range(MPa): -, Power Supply: DC24V, Options: -, Accessories/options: ordered separately: Power supply cable included (10 m) / with bracket, I/O specifications: None, Connector options: -, Model: Standard type, Bar length(mm): 1,960
Type: 40 (Standard Type), Bar Length: 1840mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: 3m, One-Touch Fitting: ø10, Bracket: B (Bracket), Sensor: Type 40: N/A; Type 41 & 42: Built-in Auto Balance Sensor, Option: X10 [Non-standard Bar Length (Not Required with Electrode Cartridge
Type: 40 (Standard Type), Bar Length: 1960mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: 3m, One-Touch Fitting: ø10, Bracket: B (Bracket), Sensor: Type 40: N/A; Type 41 & 42: Built-in Auto Balance Sensor, Option: X10 [Non-standard Bar Length (Not Required with Electrode Cartridge
Type: 40 (Standard Type), Bar Length: 1960mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: Z (10m), One-Touch Fitting: ø10, Bracket: B (Bracket), Sensor: Type 40: N/A; Type 41 & 42: Built-in Auto Balance Sensor, Option: X10 [Non-standard Bar Length (Not Required with Electrode Cartridge
Type: 40 (Standard Type), Bar Length: 2140mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: Z (10m), One-Touch Fitting: ø10, Bracket: B (Bracket), Sensor: Type 40: N/A; Type 41 & 42: Built-in Auto Balance Sensor, Option: X10 [Non-standard Bar Length (Not Required with Electrode Cartridge
IONIZER, BAR TYPE, IZS30,31,40,41,42. Bar Type Ionizer. 1800.00000 lb. 877.
S 116 128.5 ZZ 198 216.5 Size 32 40 P317010-13 One set of the actuator requires two sets of the hexagon socket head cap screws. 11-10-18 19 Series MRQ Made to Order Specifications: -X10 Please consult with SMC for further information on specifications, dimensions and delivery. Long Stroke (101 to 200 mm) -X10 4 Refer to the table of number of the auto switches mounted below.
(1) (9) (10) (2) (3) (4) (15) (16) (7) (11) (8) (12) (5) (17) (18) (21) (19) (6) (20) (13) (14) OFF 1 PWR LED() ON 2 RUN LED() EtherNet/IP USB USB 3 USB USB LED() USB 4 ALM LED() 5 USB USB ) (+)(-) 6 C PWR (2 ) x100 7 x10 IP x1 x10 x100 IP 4Byte x1 8 MS, NS LED EtherNet/IP 9 ENC1 (16 ) 1 10 MOT1 (6 ) 11 ENC2 (16 ) 2 12 MOT2 (6 ) ) (+) 1 (+) 1 (+) 13 CI 1 2 2 (+)2 (+
One set of the actuator requires two sets of the hexagon socket head cap screws. 1.5-18 Series MRQ Made to Order Specifications -X10 Consult SMC for further information on specifications, dimensions and delivery. Symbol Long Stroke (101 to 200 mm) -X10 4 Refer to the table of number of the auto switches mounted below.
Guide type High rigidity direct acting guide H X10 Non-standard motor Series Series 10 Series 20 Series 30 Limit switch 10 20 30 Cable entry direction None B contact specification 2 pcs.
For actuators with a stroke more than 1000mm, set parameter PA05 (Feed function selection) to 0001 and the "Feed length multiplication (STM) (Multiplier)" value to x10. Set the feed length multiplication (STM) (Multiplier) of target position in parameter No. PA05 (Feed function selection). Parameter No.