A 13 15 22 06 08 10 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 End bracket/IZS40-BE 35 22 4.5 30 44 2 x 5.4 18 105 33 L 33 Intermediate bracket/IZS40-BM 55 35 22 4.5 36 30 18 2 x 5.4 A 105 33 A A-A section 432 Ionizer IZS40/41/42 Series Dimensions Feedback sensor/IZS31-DF 2 x 3.4 Amplifier 2 x 3.4 Head 1500 3500 IZS IZS 9 16.6 13 SMC IZN 4.8 10.2 25 58 4.8 69 23 87.5 IZF 78 ZVB
Tubing size Tensile force of tubing [N] 2, 3.2, 1/8" 5 4, 5/32", 3/16" 8 6, 1/4" 12 8, 5/16" 20 10, 3/8" 30 12, 1/2" 35 16 50 2) Removal of tubing (1) Push the release button flange evenly and sufficiently to release the tube. Do not push in the tubing before pressing the release button. (2) Pull out the tubing while keeping the release button depressed.
[] 60Hz 50Hz Fig 9.5-1 Heating capacity(HRS012--10, HRS018--10) 9.5.2 HRS012--20,HRS018--20, HRS024--20 1000 1000 Ambient Ambient temperature temperature 800 800 5 20 25 5 Heating capacity [W] 20 25 32 40 [W] 600 600 32 40 400 400 200 200 0 0 5 15 25 35 45 5 15 25 35 45 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9.5-2 Heating capacity(HRS012--20, HRS018
/64 35/64 35/64 29/64 29/64 29/64 5/32 Typ. 17 B2 1/2 B2 B4 B6 B3 B1 B5 B3 1/2 Elbows: 10-32 Male to Tube Fibre Gasket Supplied ( *Note: also available with O Ring seal) ( Note: also available with captive rubber seal) 15/32 15/32 1/2 11 32 13 64 11 32 11 32 9/32 9/32 9/32 Typ. 3 5/32 Typ. 5/16 Hex Typ. 1/4 Hex Typ. 10LB3 1/2* 10LB2 1/2 10LB2 10LB4* 10LB3* 10LB1 18 Tees: 10-32 Male to
86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 30 40 37 16 17 depth 12 37 95 10.5 M10 x 1.5 depth 20 142 19 22 110 194 80 170 35 45 42 19 Data P GD GK GL GQ GR H I J K L M N O Q R S Bore size (mm) 20 25 32 40 M8 x 1.25 depth14 80 5.5 60 3.5 93 M5 x 0.8 54 4 4 35 105 50 25 M6 x 1 14 26 M10 x 1.5 depth18 95 9 70 4 103 M5 x 0.8 62 7 7 40 125 60 32 M8 x 1.25 14 31 M10 x 1.5 depth18 95 9
20 26.5 A 3 Z N-M5 x 0.8 thread depth 10 (N 1) x H G H 6 Bottom through-hole 4.2 M5 x 0.8 thread depth 10 GG 5H9 +0.030 depth 4.5 Bottom through-hole 4.2 0 F E 5H9 +0.030 depth 4.5 0 (mm) E F G Model GG H J K L N Z MXW12-100 91 123 82.5 30 35 114 35 51 5 280 MXW12-125 111 158 102.5 32.5 35 137 60 76 6 330 MXW12-150 136 182 127.5 47.5 40 164 85 101 6 380 8-7-13 14 Series MXW Dimensions:
L dimension 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 VS VFN Silencer (For manifold EXH port) Silencer is installed in the EXH port. 63 38 22 Dimensions 13 Silencer part no.
Note 8) The display unit conforms to the CE mark. 3 Digital Flow Switch Series PF2A For Air How to Order 4-channel Flow Monitor Remote Type Display Unit 0 M PF2A20 Output specification Option 2 (Refer to page 35.) 0 1 NPN4 outputs PNP4 outputs Accessory / Power supply output cable (2 m) Nil 4C None Sensor connector (4 pc.) Unit specification Option 1 (Refer to page 35.)
122 25% 22.5 MPa 1 E ELECTORO PNEUMATIC IP8100 P O S I T I O N E R DA 50% 75% G1/2 Electric conduit 35 100% 4 x M8 x 1.25 depth12 Female for rear mounting View A 125 2 x M8 x 1.25 depth12 Female for side mounting 194 With optional resin cable clamp Applicable cable O.
I.D. 4 2.5 1 4 1 4 3 8 KFF04-02 KFF06-02 KFF06-03 KFF08U-02 KFF08N-02 KFF10U-02 KFF10N-02 KFF12U-02 KFF12N-02 10 33.5 17 17 19 26.8 15 15 17 15.5 1.5 1.6 25 27 30 33.2 26.5 15.2 3 6 6 4 12 35.2 28.5 5 6 4 5 5.5 6.5 7 8 11 17 21 30 35 45 1 4 14 17 33.2 26.5 15 16.2 8 28 10 6.5 7.5 1 4 32 17 17 34.8 27.5 15 18.8 12 8 9 35 36 1 4 17 19 35.3 28.5 15 19.3 98 Series KF Insert Fittings Bulkhead
) a : Work piece acceleration (mm/sec) Me: Dynamic moment 1000 m L1 3 0 1 2 Transfer load m (kg) a = 1000 300 L2 (mm) L2 a = 2000 200 a = 3000 100 Mer m 3 0 1 2 Transfer load m (kg) a = 1000 a 2000 a = 2000 Mey L3 (mm) a = 3000 m 1000 L3 3 0 2 1 Transfer load m (kg) Refer to page 304 for deflection data. 210 5 Phase Stepper Motor/Without Motor Brake Series LXF Dimensions/LXFH5BC Scale: 35%
The other main residual gases have mass numbers of 28 and 35. (from P/A data) S P1P2 40 Technical Data Series XL Total pressure 13 This is the sum of all partial pressures and is equal to P=nkT, where the pressure is P, the number of gas molecules is n, Boltzmanns constant is k, and the absolute temperature is T.
position double VFA3230(-P) 01 02 63.5 23 1/8, 1/4 [4 (A), 2 (B) port] 1/8, 1/4 [4(A), 2(B)port] 2 x 4.3 (For mounting) 2 x 4.3 (For mounting) 25.5 10 SYA 10 4A 4A 5 SYJA 1 1 26.4 26.4 20 20 10 1/8 (Pilot port: Upward) 1/8 (Pilot port: Upward) 2B 2B VZA (1.6) 66 23 19 81 VFA VFA 71 (6) 1/8 [Pilot port: Lateral (-P)] VFRA 1/8 [Pilot port: Lateral (-P)] VPA4 (45) (55) 31.5 31.5 36 36 SYJA 35
(The SI unit type is provided for use in Japan.) 14-4-35 18 Series ARM11A/B Common Supply Block ARM11A 1 S 01 3 Z A 1 2 3 4 5 6 1. IN piping position 4. Option 2.
A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail 12.5 (Pitch) 5.25 7.5 AXT100-DR-l VQ Enter suffix the number from DIN rail dimensions table below.
The other main residual gases have mass numbers of 28 and 35. (from SMC data) S P1P2 40 Technical Data Series XL Total pressure 13 This is the sum of all partial pressures and is equal to P=nkT, where the pressure is P, the number of gas molecules is n, Boltzmanns constant is k, and the absolute temperature is T.
(mm) One-touch fitting 4 tube 6 tube 8 tubing 34 35 10 to 16 38 39 20 to 32 134 136 40, 50 Weight by Stroke (g) Pad dia.
Features 5 Air Dryer Variations Series IDF E/F/D Standard inlet air temperature type Rated inlet air temperature: 95, 104F (35, 40C) [Max. inlet air temperature: 122F (50C), 140F (60C) (F and FS type only)] Refer to SMC website for details.
Connection thread size Wrench tightening angle after hand-tightening [deg] Proper tightening torque [Nm] G1/8 10 to 20 3 to 4 G1/4 15 to 35 4 to 5 G3/8 15 to 35 8 to 9 G1/2 15 to 35 14 to 15 600 AS-FS Series Specific Product Precautions 3 Be sure to read this before handling the products.