Linear Guide Double Axis Slider, ELECTRIC ACTUATOR, 5.2 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Linear Guide Double Axis Slider, ELECTRIC ACTUATOR, A22, 14.47 lb
Ethernet/IP Direct Connect, ELECTRIC ACTUATOR CONTROLLER, 0.13 lb
Linear Guide Double Axis Slider, ELECTRIC ACTUATOR, 12.08 lb
ETHERNET/IP DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 0.21000 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Linear Guide Double Axis Slider, ELECTRIC ACTUATOR, A22, 13.09 lb
Linear Guide Double Axis Slider, ELECTRIC ACTUATOR, A22, 8.27 lb
ETHERNET/IP DC CONTROLLER, ELECTRIC ACTUATOR CONTROLLER, N31, 0.23000 lb
CDA2 B 50 200 X1184 B31J S With built-in special magnet Number of auto switches Cylinder stroke Description 2 pcs. 1 pc.
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
Switch (When equipped with switch) Internal Pilot Manifold L Dimension n: Stations External Pilot Manifold L Dimension n: Stations L n 4 173 162.5 145 14 L n 4 185.5 175 155.5 15 2 148 137.5 124 12 3 160.5 150 134.5 13 5 185.5 175 155.5 15 6 198 187.5 166 16 7 210.5 200 176.5 17 8 210.5 200 187 12 9 223 212.5 197.5 13 2 160.5 150 134.5 13 3 173 162.5 145 14 5 198 187.5 166 16 6 210.5 200
Status (7): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range. Status (8): TEMP READY signal turns OFF when 200 sec has passed after the temperature rises above the High range. TEMP READY alarm (AL12) is simultaneously activated.
CCT40-200 SCCS, #1 CCT63-200 SCCS, #2(#2+#13) CCT100-200 SCCS, #3(#3+#14) CCT63 SCCS, #13 CCT100 SCCS, #14 CCT100-200 SCCL, #1(#1+#12) CCT160-200 SCCL, #2(#2+#13) CCT100 SCCL, #12 CCT160 SCCL, #13 4.12-7 Air-hydro Converter Series CCT How to Order CCT 63 100 Effective oil level stroke (mm) Air-hydro converter Converter nominal size/stroke (mm) 63 100 160 50, 100, 200, 300, 400, 500
20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 1/8 Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Non-lube Double acting, Up to 1500 25, 50, 75, 100, 125, 150, 200 Single rod (40 to 63) 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note 1) When exceeding the standard strokes above, the particle generation class may not be satisfied.
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 1000 500 Not available with air cushion. Other strokes available on request.
(2") 075 (3/4") 088 (7/8") 106 (1 1/16") 125 (1 1/4") 150 (1 1/2") 200 (2") Mounting Height (NCDM) (in) D-C7 D-C80 D-H7 D-H7W D-H7BAL D-H7F D-B5 D-B6 D-B59W D-H7C D-G59 D-K59 C-C73C D-C80C Auto switch model HS 0.96 1.02 1.12 1.22 1.34 1.59 HS 0.87 0.93 0.98 1.08 1.20 1.46 HS 0.98 1.04 1.14 1.24 1.36 1.61 Bore 075 (3/4") 088 (7/8") 106 (1 1/16") 125 (1 1/4") 150 (1 1/2") 200 (2") 6-14-
In the graph, find where the lines representing an operating pressure of 0.6 MPa and a load weight of 200 kg intersect.