Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KOZ (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)
Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 6 (12 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override), Lead Wire Length: KOZ (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C
Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (External pilot port) Manual override (Non-locking) Electrical entry (2.3) 2-5.6 (Mounting hole) Rc 1/8 (PE port) Max. 10 (With direct manual override) (Grommet terminal) 5-Rc 3/8, 1/4 ( ): Rc 1/4 0 1 0 1 0 1 0 1 0 1 0 1 2 position double: VFR321 -E, VFR321 -DZ 0 1 0 1 3 position closed center: VFR331 -E,
VQ 0 5 1 1 0 1 VP4
P Note 1) U S U S U S U S w AXT100-1-J 20 Note 1) AXT100-1-FU15 AXT100-1-FS e Note 1) Top entry connector for PU, JU while side entry connector for PS, JS.
P Note 1) U S U S U S U S w AXT100-1-J 20 Note 1) AXT100-1-FU15 AXT100-1-FS e Note 1) Top entry connector for PU, JU while side entry connector for PS, JS.
(1) [EX124-SCS2](2) EX120-SMJ1(-XP)(1) [EX124-SMJ1](2) AXT100-1-P (4) U S w e r U S U S VZ AXT100-1-F (4) U S AXT100-1-GU20 Note 1) Suffix XP for dust-proof SI unit.
(mm) Port size R 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.