C 6 13.5 4.5 0.5 Width across flats F 10 Tightening torque: Tighten within 10 1 Nm. G1/4 (mm) Part no.
10 1 10 1 0.1 Weight m(kg) Weight m(kg) Weight m(kg) 20 16 10 6 20 1 20 16 16 0.1 0.01 10 10 6 6 0.01 0.001 0.1 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L(mm) Overhang L(mm) Overhang L(mm) 1 kg = 2.2046 lb 1 kg = 2.2046 lb 1 kg = 2.2046 lb Graph 5 Load eccentricity 100mm Graph 8 Load eccentricity 100mm Graph 11 Load eccentricity 100mm 1 10 10 0.1 1 Weight m(kg) Weight
Metal bowl with level gauge w q With bowl guard e q w Drain guide 1/4 N R q w Non-relieving type Flow direction: Right to left Note 1) The circled numbers indicate the order in which the units are assembled.
Q Q Q Q Q Q Q Q Q Q Q Q 157 Q MXP Series 6, 10, 12, 16 Traveling parallelism Traveling parallelism: 0.004mm Parallelism: 0.02mm Traveling parallelism on guide block top side Traveling parallelism on guide block side Run out indication when body is fixed on standard base and cylinder is fully extended. MXP10,12,16 Cylinder with built-in linear guide.
Cooling capacity*2 kW 9 1*8 19 1*8 26 1*8 Heating capacity*3 kW 1.5 1 4.0 1 6.0 1 Temperature stability*4 C CH1: 0.1/CH2: 0.5 Rated flow (Outlet pressure) L/min 45 (0.43 MPa) 10 (0.45 MPa) 45 (0.45 MPa) 10 (0.45 MPa) 125 (0.45 MPa) 10 (0.45 MPa) Maximum flow rate L/min 120 16 130 16 180 16 Maximum pump head m 50 49 55 49 68 49 Settable pressure range*5 MPa 0.10 to 0.50 0.10 to 0.49 0.10 to
G H J1 J2 K Q R1 R2 V Note 1) Refer to p.1.10160 for details.
12 14 1/8 1/8 1/8 0 0.039 1/4 With Rod Boot S 62 62 64 88 TD 8 9 9 10 TT 10 10 10 11 TX 32 40 40 53 TY 32 40 40 53 TZ 52 60 60 77 Z 36 40 40 44.5 ZZ 116 120 122 154 h Symbol Bore size (mm) 20 25 32 40 e f B3 Stroke Bore size (mm) 1 to 50 68 72 72 77 51 to 100 81 85 85 90 101 to 150 93 97 97 102 151 to 200 106 110 110 115 201 to 300 131 135 135 140 301 to 400 156 160 160 165 401 to 500 181
HRZ x V x C x iT it m x C x (T0 Tt) it Q = = HRZD 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 HRW Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = HECR 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = HEC Q x t: Heat capacity [kJ] Thermo-chiller Water bath 6977 [W] = 7.0 [kW] 20C HEB Cooling
Q Q Q Q Q Q Q Q Q Q Q Q Q 133 Q MXW Series 8, 12, 16, 20,25 Linear guide table provides long stroke Linear guide Long stroke (up to 300mm) Linear guide provides long stroke and smooth operation without vibration.
How to Order 25A-LEFS 25 H R B 200 S 1 6N 1 q r w e t u y i o !0 !1 !
M5 M5 K M Q R 50 60 63 66 70 Q 40 R Q 58 R S 46 Q 95 R S 62 T U 46 56 56 W X 11 13 13 Y Normally closed Normally open VX212 VX222 VX232 VX210 VX220 VX220 VX230 VX230 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 1/4, 3/8 1/4, 3/8, 1/2 18 22 30 22 30 (76) (86) (93) 2, 3, 4.5 3, 4.5, 6 8, 10 3, 4.5, 6 8, 10 40 45 50 45 50 68 78 85 85 92 30 9 19.5 27 6 8 8 8 8 12.8 19.5 42.5 42.5 42.5 85 36 46 46
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
(mm) Port size R 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.
C.O. 4 220V AC 50/60Hz 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 10 5 24V DC 6 12V DC 7 240V AC 50/60Hz 15 2 9 Other 20 3 Option 25 4 1 1 1 2 Valve size 5 to 7 32 5 1 4 1 2 40 6 50 7 Note) Only air operated type.
10 10 10 5 5 5 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 0 1 2 3 4 5 6 8 9 10 11 13 7 12 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) 50 63 1000 1000 Recommended driving force Fn (N) Recommended driving force Fn (N) 500 400 500 300 300 200 200 Usable range 100 100
5 5 24 M20 X 1.5 18 8 28 12 15.5 8 M8 X 1.25 20 15 12 13 20 8 41 20 1 to 300 17 6 5.5 30 M26 X 1.5 22 10 33.5 12 19.5 8 M10 X 1.25 22 15 12 13 25 8 45 26 34.5 1 to 300 17 6 5.5 M26 X 1.5 22 12 37.5 15 19.5 10 M10 X 1.25 27 15 20 13 32 8 45 26 21.5 42.5 1 to 300 22 8 7 M32 X 2 24 14 46.5 15 21 10 M14 X 1.5 33 20 16 40 11 50 32 With rod boot h Symbol Bore S U Z ZZ P 1/8 1/8 1/8 1/4 RR Stroke
1 @1 !8 !5 w !9 !0 !7 u !7 w @1 !9 !3 @3 !2 !0 o @0 i A A MX MTS MY CY !4 !3 y e !2 q r t o !6 @0 !4 !1 q !6 i t y e !5 r u !
D-M9A D-M9V Qty. of auto switches mounted D-A9 D-M9 D-P3DW Note 1) 5 10(5) 15 (10) 15 (5) 1 pc. 10 15 5 10 10 15 (10) 15 (5) 2 pcs. 10 15 5 Note 1) 25 is only applicable for D-P3DW.
134.5 169 189 Bore size (mm) 32 40 50 63 80 100 GE GR GF J MB K MM N P Q H S T V VA W ZZ 88.5 96.5 111.2 123.5 157 177 M10 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 4 5 9 11.5 17 18.3 19.5 22.4 20.7 26 26 M6 x 1.0 M6 x 1.0 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 4 4 5 5 5 5 6 6 7 7 10 10 27 27 31.5 31.5 38 38 1/8 1/4 1/4 3/8 3/8 1/2 37 41.5 47.5 55 61 68 154 161 183 197