1400 or less 1600 or less Order Made Made to Order Mounting Bracket Part No.
l/min (ANR) 4 4 Based on condition ; Based on condition ; IDU4D is selected as the model to process an air flow larger than 412 l/min IDF11C is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2.
Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
: Oversized Rod Cylinder Symbol -XB5 1 Oversized Rod Cylinder A cylinder that has been made stronger through the use of a piston rod with a larger diameter.
V V V V V V V 32 to 125 D Built-in magnet V V V V V V V V MBl-lJ K With rod boot V V V V V V V V 25A Copper (Cu) and Zinc (Zn)-free Note 1) 32 to 100 V v v v v v v v MBlR V Water resistant V v V v V v V v 10Clean series Note 6) v v v v v v v v 32 to 125 20Copper Note 5) and Fluorine-free Note 6) Note 9) Note 9) Note 9) Note 9) Note 9) Note 9) Note 9) Note 9) XAl Change of rod end shape XB5
Thomas Oil-less Rotary Vane Compressor / Vacuum Pump Flow Rate: 33 LPM , 33 LPM, Max Pressure: 20.3 PSIG / 1400 mbar , 20.3 PSIG / 1400 mbar, Max Vacuum: 27.5 in HgV / -930 mbar , 27.5 in HgV / -930 mbar, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 8.27 in / 210 mm Width: 2.32 in / 59 mm Height: 2.32 in / 59 mm , Length
Thomas Oil-less Rotary Vane Compressor / Vacuum Pump Flow Rate: 36 LPM , 36 LPM, Max Pressure: 20.3 PSIG / 1400 mbar , 20.3 PSIG / 1400 mbar, Max Vacuum: 24.8 in HgV / -840 mbar , 24.8 in HgV / -840 mbar, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 8.27 in / 210 mm Width: 2.32 in / 59 mm Height: 2.32 in / 59 mm , Length
Operating range Cylinder mounting bracket, by stroke/ Auto switch mounting surfaces 80 301 to 1400 100 301 to 1500 Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are not used.) Note 2) Long stroke applies to the axial foot and rod flange types.
Unit: N Operating pressure (MPa) Bore size (mm) Operating direction Rod size (mm) Piston area (mm2) 0.5 0.6 0.4 0.3 756 630 504 378 OUT 1260 40 20 566 472 377 283 IN 943 1180 980 784 588 OUT 1960 50 20 990 825 660 495 IN 1650 1870 1560 1250 934 OUT 3120 63 20 1680 1400 1120 840 IN 2800 422 A Clamp Cylinder CK1 Series Construction CKG140, 50, 63 Rod mounting type #0 q @1 w e @2 @0 !4 y !
Opening Range of Throttle Valve and Driving Speed Conditions: Operating pressure 0.5 MPa, Horizontal mounting, No load, Spring return side The speeds shown in the graph are for reference. 40 40 1400 50 50 1200 Piston speed (mm/s) Related things about auto switches and the mounting brackets part numbers are the same as these of Series CV3.
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.
D20Weight Rotating angle Flange (g) Basic weight (g) Add'l stroke weight (g/mm) Size 80 to 100 1400 4 500 32 170 to 190 1500 80 to 100 2100 40 5 500 170 to 190 2300 Calculation: (Example) MRQBS32-50CA Basic weight 1400 g 4 x 50 = 200 g Stroke additional weight Total 1600 g For the weight of auto switch alone, refer to page 11-11-1.
Opening Range of Throttle Valve and Driving Speed Conditions: Operating pressure 0.5 MPa, Horizontal mounting, No load, Spring return side The speeds shown in the graph are for reference. 40 40 1400 50 50 1200 Piston speed (mm/s) Related things about auto switches and the mounting brackets part numbers are the same as these of Series CV3.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1490 1320 1650 1160 990 495 660 825 330 1650 IN 2810 2500 3120 2180 1870 936 1250 1560 624 3120 OUT 63 20 2520 2240 2800 1960 1680 840 1120 1400 560 2800 IN 4530 4020 5030 3520 3020 1510 2010 2520 1010 5030 OUT 80 25 4090 3630 4540 3180 2720 1360 1820
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1490 1320 1650 1160 990 495 660 825 330 1650 IN 2810 2500 3120 2180 1870 936 1250 1560 624 3120 OUT 63 20 2520 2240 2800 1960 1680 840 1120 1400 560 2800 IN 4530 4020 5030 3520 3020 1510 2010 2520 1010 5030 OUT 80 25 4090 3630 4540 3180 2720 1360 1820
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 16 100, 200, 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1400, 1600, 1800, 2000 3000 25, 40 5000 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. When exceeding a 2000 mm stroke, specify -XB11 at the end of the model number.