SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2F16-300R-H7B"

PLC Yes 200V or less Grommet 12V No Reed switch Solid state switch Relay PLC 100V Yes No Yes No 2-wire IC circuit 5V, 12V 12V 5V, 12V 12V 100V or less 24V Connector IC circuit 24V or less A33 A34 A44 PLC Terminal conduit 12V 100V, 200V Yes Relay PLC DIN terminal Diagnostic indication (2-color display) B59W Grommet H7A1 H7A2 H7B H7C G39 K39 H7NW H7PW H7BW 3-wire (NPN) 3-wire (PNP) IC

Indicator Type Special function Electrical entry Wiring (Output) DC AC Band Perp In-line Rail mounting Applicable load Pre-wired connector 0.5 (-) 5 (Z) 3 (L) None (N) 3 wire (Equiv. to NPN) A76H C76 5V IC Reed switch Solid state switch Grommet A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F 200 V 200 V 24 V C73 C73C H7A1 H7A2 H7B

Grommet in-line P P P F9N, F9P, F9B F7NWV, F7BWV P Grommet perpendicular With diagnostic output P P F9NV, F9PV, F9BV F7LF, F79F P P P P M5NW, M5PW, M5BW F7BA Water resistant P P Direct mount Grommet in-line P P With timer Y7NW, Y7PW, Y7BW F7NT P P 2 color indicator Magnetic field resistant Grommet perpendicular Y7NWV, Y7PWV, Y7BWV P5DW P P P P P P P F9NW, F9PW, F9BW H7A1, H7A2, H7B

IC circuit Relay, PLC PLC 100V Yes (B53) (B54) (B64) B53 B54 B64 Grommet 12V Reed switch Solid state switch 100V, 200V 200V or less No 2 wire 24V C80 C73C C80C B80 B73C B80C 5V, 12V 12V IC circuit 100V or less Relay, PLC Yes No Connector IC circuit 5V, 12V 24V or less Diagnostic indication (2 color indicator) (B59W) B59W Yes Grommet H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA 3 wire (NPN) 3 wire

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 65, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 240, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 325, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 340, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: H7B, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 270, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7B, Lead Wire Length