[A ir ] dry air, N2 [FLU] Operating fluid [F 3] Check that the above preparation has been performed correctly, then part A shown should be pressed in by hand to make temporary connection. Part A should then be pressed in using a suitable tool, such as pliers. The sensor connector cannot be re-used once it has been fully crimped.

Only air, N2, are applicable. [ H_1] Hysteresis of OUT1 : The outputs will continue to operate during setting. : If a button operation is not performed for 30 seconds during the setting, the display will flash.

Only air, N2, are applicable. [ 25] 25 L/min (PFMC7501) End stop position Set value [P_1] [ H_1] Hysteresis of OUT1 [ 50] 50 L/min (PFMC7102) Hysteresis [H_1] 225o [ 100] 100 L/min (PFMC7202) Flow [L/min] Do not use the product in a place where static electricity is a problem.

PF-OMK0003CN-E PFMV505 PFMV510 PFMV530 PFMV505F PFMV510F PFMV530F N2 (JIS B8392-1 1.1.21.6.2ISO8573-1 1.1.21.6.2) 2 2 2 () 00.5 01 03 -0.50.5 -11 -33 1 L/min L/min L/min L/min L/min L/min 2F.S. 3 2F.S.(1535 ) (25) 5F.S.(050 ) 2F.S.(0300 kPa) 5F.S.(-700 kPa) (0kPa 4) -70300 kPa -100400 kPa 500 kPa 5 15 V 5 ms 1 k DC1224 V10(p-p) 10() 16 mA IP40 050 () 050 -1060 () 3585R.H

Only air and N2 are applicable. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation.

Only air, N2, are applicable. Flow direction Arrow Default setting Turn the power off and on again. If the failure cannot be solved, contact SMC. An internal data error has occurred. Function (Main display) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.

Only air, N2, are applicable. [6000] 6000 L/min (PF3A712H) [F 1] [ 150] 150 L/min (PF3A703H) The accumulated flow has exceeded the accumulated flow range. (For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.

Only air, N2, are applicable. Flow direction: Left Right Flow direction: Right Left Default setting Rotation of the display Function (Main display) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. (2) Press the or button to change the set value.

Only air, N2, are applicable. Flow direction: Left Right Flow direction: Right Left Temperature exceeding the upper limit of the set temperature range is applied. Reset applied temperature to a level within the settable temperature range. Temperature below the lower limit of the set temperature range is applied.

(When reversed output is selected, the main screen displays n1/n2) Please refer to the "List of output modes" on page 38 for the relationship between the set values and operation. -31No.PF-OMA1011-A Function Selection Mode Function selection mode After selecting the channel, in measurement mode, press the S button for 3 seconds or longer (but less than 5 seconds), to display [F 0].

(When reversed output is selected, the sub display (left) shows [n1/n2].) : Set OUT2 in the same way. : Setting of the normal/reverse output switching and hysteresis/window comparator mode switching are performed with the function selection mode [F 1] Setting of OUT1 and [F 2] Setting of OUT2. Snap shot function The current flow value can be stored to the switch output ON/OFF set point.

20 ) [1PH] 3 (OUT2) [2nL] (20 ) [2PL] 3 (OUT2) [2nH] (20 ) [2PH] () -28No.PF-OMO0007CN [F_3] [-] 9L,3 3 9 -29No.PF-OMO0007CN <> 3[F_][d_][unL] [unL] [Loc] 3 <> 3[Loc] [unL] 3 -30No.PF-OMO0007CN -31No.PF-OMO0007CN () IN IN -32No.PF-OMO0007CN IN (30 ) -33No.PF-OMO0007CN (OUT1) 80 mA OUT1 OFF (OUT2) 80 mA OUT2 2 2 () -34No.PF-OMO0007CN PF2A710 PF2A750 PF2A711 PF2A721 PF2A751 N2

This is a legacy product, and replaced byPF2M711-N2-B IFW/PFW FLOW SWITCH. DIGITAL FLOW SWITCH. INSTRUMENTATION. IFW/PFW 1/4INCH NPT VERSION. .39683 lb. DB.

Stepless control of air pressure proportional to an electrical signalMaximum supply pressure: 5.0 MPaSet pressure range: 0.01 to 3.0 MPaMaximum flow rate: 3000 L/min[ANR]Fluid: Air, N2, O2, ArWetted parts: Fluorine grease, Hi Pressure Electro-Pneumatic Regulator, REGULATOR, ELECTROPNEUMATIC, 853, 570.00000 lb

Nil Without option B With lock N Without (Roller specification) Driver type Cable type Size Compatible Power supply Nil Without cable drivers voltage [V] 25 32 40 S Standard cable Nil Without driver R Robotic cable A1 LECSA1-S 100 to 120 (Flexible cable) A2 LECSA2-S 200 to 230 Cable length[m] B2 LECSB2-T 200 to 240 Nil Without cable C2 LECSC2-T 200 to 230 2 2 S2 LECSS2-T 200 to 240 5 5 N2

C2 LECSC2T S2 LECSS2T N2 LECSN2T 92 LECSN2T-9 E2 LECSN2T-E P2 LECSN2T-P -4- 1.1.2 Specification LESYH*(D,R,L)*S2/S3 Motor type S2/S3 Model LESYH16*S2 LESYH25R/LS3 LESYH25DS3 Parallel In-line Stroke[mm] 50,100 50,100,150 50,100,150 Horizontal 8 12 12 Max. work load [kg] Vertical 6 12 10 20 10 20 Force [N] (Set value: 15 to 30%) *1 65 to 131 127 to 255 79 to 157 154 to 308 98 to 197 192 to

Stepless control of air pressure proportional to an electrical signalMaximum supply pressure: 5.0 MPaSet pressure range: 0.01 to 3.0 MPaMaximum flow rate: 3000 L/min[ANR]Fluid: Air, N2, O2, ArWetted parts: Fluorine grease, Hi Pressure Electro-Pneumatic Regulator, REGULATOR, ELECTROPNEUMATIC, 853, 570 lb

Stepless control of air pressure proportional to an electrical signalMaximum supply pressure: 5.0 MPaSet pressure range: 0.01 to 3.0 MPaMaximum flow rate: 3000 L/min[ANR]Fluid: Air, N2, O2, ArWetted parts: Fluorine grease, Hi Pressure Electro-Pneumatic Regulator, REGULATOR, ELECTROPNEUMATIC, 853, 570 lb

Stepless control of air pressure proportional to an electrical signalMaximum supply pressure: 5.0 MPaSet pressure range: 0.01 to 3.0 MPaMaximum flow rate: 3000 L/min[ANR]Fluid: Air, N2, O2, ArWetted parts: Fluorine grease, Hi Pressure Electro-Pneumatic Regulator, REGULATOR, ELECTROPNEUMATIC, 853, 570 lb

Options include rod attachments and auto-switch capabilities.Two styles of clevis widths *, Built-in speed controller, Heavy duty coil scraper, Piping entry orientation can be selected as required, Compact and lightweight, SWITCH CASSETTE KIT, ACTUATOR, CKZN SLIM LINE CLAMP CYLINDER, N2, 50MM CKZN SLIM LINE CLAMP CYL, .43120 lb