M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

4 A 4 A 4 A 4 A 4 P 1 P 1 A 4 A 4 A 4 A 4 X P 1 P 1 A 4 2n2-One-touch fitting 2-One-touch fitting 2n1-M5 x 0.8 (A, B ports) (A, B ports) Applicable tube O.D.: 4 6 (X, PE ports) Applicable tube O.D.: 6 (L4) L3 Applicable connector: D-SUB equivalent { } JIS-X-5101 MIL-C-24308 Connector case attachment lever (both sides) (3.2) 101.2 9 3.1 Lateral connector entry 8 36.3 5.5 35 6.5 18 28.8 34

B A B A B A B 4.7 35 44.4 <45.1> 23.5 10.2 26 3 R A A G: Approx. 300 H: Approx. 600 DIN rail (VZ1000-11-1-) (Pitch) = 10.5 13.5 24.3 33.2 (M5 port) DIN rail holding screw 2n1-M5 x 0.8 (ports A, B) 2n2-One-touch fitting (ports A, B) Applicable tube O.D.: 4 6 L2 [rail mounting hole pitch 12.5] (5) L1 9 Cassette Type Manifold Series SY3000/5000/7000 Note) [ ] are for AC type, while < > are

AXT632-45-1 AXT632-45-2 AXT632-45-4 AXT632-45-5 AXT632-45-6 AXT632-45-7 AXT632-45-8 AXT632-45-9 AXT632-45-10 AXT632-45-11 AXT632-45-12 AXT632-45-13 Mounting bolt Size M5 x 35 with SW M5 x 15 with SW M5 x 45 with SW M5 x 60 with SW M5 x 65 with SW M5 x 70 with SW M5 x 75 with SW M5 x 90 with SW M5 x 95 with SW M5 x 100 with SW M5 x 105 with SW M5 x 115 with SW VK Option mounting diagram SMC

Proper tightening torque Nm {kgfcm} Tightening torque for piping Connection threads M5 Rc(PT) 1/8 1.5 to 2 {15 to 20} 7 to 9 {71 to 92} Reference: Tightening into the M5 fitting threads After tightening by hand, tighten about 1/6 of a turn further using a tightening tool.

Fittings & Tubing Air Cylinders Rotary Actuators 21 22.5 13.5 86.2 M5 x 0.8 (External pilot port) 71.9 10.4 21 21.5 M5 x 0.8 (Pilot EXH port) 2 x 4.3 (For mounting) A B PE SMC 38 46 A B A B B A X Manual override P A side: Orange B side: Green EA EB 21.5 21 61 69 6.4 (Light/surge voltage suppressor) (L = 300 to 5000) 121.4 115.8 M12 waterproof connector 60.3 58.5

(With mounting screw) For VKF334: VKF300-S-01 For VKF332: VKF300-13A-2 For VKF333: VKF300-11A-2 For VKF334: VKF300-11A-1 i 3 4 For VKF33 : VKF300-6A-1 2 sets per unit required Bushing assembly o Resin 4-13-5 6 Series VKF300 Dimensions: Single Type M5 01 DIN terminal: VKF332-DM5 01 Body ported Grommet: VKF332-G17 Rc 1/8, M5 x 0.8 2(A) port Manual override (Non-locking) A A 18.5 20.5 300

type A port: Rc 1/8 V100 S070 Common SUP/Individual EXH VQD How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve VK332--M5(-Q) VK332--01(-Q) VV3K3 05 21 VQD-V A port: Rc 1/8, M5 x 0.8 VK VK Applicable blanking plate assembly VK300-42-1A Valve stations P, R port thread type 01 1 station VT Nil Rc G NPT NPTF CE-compliant 20 20 stations 00F 00N 00T Q CE-compliant

T h e V YH y R e g R a n g e i s c o n s t r u c t e d b y u t i l i z i n g a standard control unit either alone (VY1D00-M5) or as a Pilot Valve controlling one of the Range of VEX1 Power Valves.

Align the ejector assemblies r, end block (R) w, and end block (L) e using positioning pins (at the two a positions) and fasten with a hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0.6 Nm0.06 Nm). XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 10

Align the ejector assemblies r, end block (R) w, and end block (L) e using positioning pins (at the two a positions) and fasten with a hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0.6 Nm0.06 Nm). XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10

ARJ AR425 to 935 Air-operated type Pilot pressure VBA11A VBA10A, 20A, 40A, 43A ARX Drive chamber A Governor Drive chamber A Governor Drive chamber B Booster chamber A AMR IN (Inlet) IN (Inlet) Drive chamber B ARM VBA22A, 42A Piston rod Piston rod ARP Booster chamber A IR-A Piston Piston IR Check valve Booster chamber B Booster chamber B Check valve IRV Switching valve Switching valve E OUT

D-B5/B64 D-G5/K59 D-G5W/K59W (A set of band and screw) BA-02 BA-01 (A set of band and screw) BA-32 (A set of band and screw) BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) BA-08 (A set of band and screw) BA-10 (A set of band and screw) Note) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform,

Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.

, AC40C-A.· Y510-□02-A, 03-A applicable models: AC40-06-A, AC40B-06-A.· Y510-□02-A, 03-A applicable models: AC40C-06-A.

P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve VK332--M5 VK332--01 Applicable blanking plate assembly VK300

Indicator Insulated adapter (PPS) Set Nil No L Yes O-ring (FKM) Port size Pressure type Thread type Symbol Port size Symbol Pressure type Symbol Thread type Nil Standard H High pressure 03 3/8 04 1/2 06 3/4 Nil Rc A G B NPT Component Parts a Housing assembly 1 pc. b Mounting screw: M5 hexagon socket head cap screw 2 pcs.

temperature of 20C bend the tubing into a U shape.

Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.