SMC Corporation of America
Elite Part Number Search
Search Results "RZQA32-100-45"

, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation. 75 100 + 100 (n 2) (n = 2, 3, 4, 5) D-G39/K39 D-A3/A44 35 + 30 (n 2) (n = 2, 3, 4, 5) 10 35 100 Note 1) Auto switch mounting Auto switches 2 pcs.

Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) * 5 The work load conditions which require Regeneration option when operating at the maximum speed (Duty ratio: 100%).

16 54 35 6.6 100 70 130 M10 x 1.5 depth 18 65 30 26.5 35 109 75, 100 125, 150 200, 250 300 M6 x 1 depth 12 19 118 80 11 depth 8 35 100 16 16 60 35 6.6 106 80 73 135 M10 x 1.5 depth 18 35 29 40 129 M8 x 1.25 depth 16 22 150 100 14 depth 10 40 120 19 19 75 50 9 134 95 93 170 M12 x 1.75 depth 21 45 32 50 152 M10 x 1.5 depth 20 22 170 120 17 depth 12 45 150 21 25 90 56 11 152 115 103 194 50

Possible to use in vacuum to 100 kPa Applicable Tubing Tubing material FEP, PFA, Nylon, Soft nylon, Polyurethane Tubing O.D. 4, 6, 8, 10, 12, 16 Specifications Fluid Air, Water 1 Operating pressure range 2 100 kPa to 1 MPa Proof pressure (at 23C) 3 MPa Ambient and fluid temperature 5 to 60C, Water: 0 to 40C (No freezing) Thread Mounting section JIS B 0203 (Taper thread for piping) JIS B 0205

(100) 44.5 112 16 22 1 2 KGT16-04 40.5 46 116 Reference dimensions after R thread installation.

V to +400 V +30 V to +100 V Within 30 V 30 V to 100 V 100 V to 400 V 400 V or lower Light ON Positive Static neutralization completion Flash at 4 Hz Detects the electric potential difference and outputs in an analog voltage.

Since 45% of the clear water discharge is equivalent to 270 mL/min in the required specifications, 270 mL/min 0.45 = approximately 600 mL/min, indicating that a discharge rate of 600 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow-rate characteristic graphs. Viscosity Transfer is possible up to about 100 mPas.

M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.

+ A = 100 y, z + A 100 10 y, z + A = 200 y, z + A = 200 y, z + A = 300 y, z + A = 300 1 1 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 800 Stroke [mm] Stroke [mm] [Graph 6] Allowable load mass by stroke 32 [Graph 5] Allowable load mass by stroke 25 100 100 y, z + A = 0 y, z + A = 0 y, z + A = 50 y, z + A = 50 10 Load mass [kg] Load mass [kg] 10 y, z + A = 100 y, z + A = 100

Table 7-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or

Cam Lever(-01) 30" 2.29o.71 45. 0.98 (0.3) ffiffiffi CHANGING PUSH BUTTONS One-WayCam Lever(-02) 30" 2 29(O.71 45" 0.98 (0.3) Plunqer(-05) 0.65 (0.2) Roller Plunoer. Inllne {{6) 30' 0.98 (0.3) Roller Plunoer.

Station 20 372 359 353 340 3 83 70 81 68 6 134 121 129 116 8 168 155 161 148 10 202 189 193 180 Station 2 66 53 65 52 4 100 87 97 84 5 117 104 113 100 7 151 138 145 132 9 185 172 177 164 11 219 206 209 196 12 236 223 225 212 13 253 240 241 228 14 270 257 257 244 15 287 274 273 260 16 304 291 289 276 17 321 308 305 292 18 338 325 321 308 19 355 342 337 324 Station n L1 L2 L1 L2 A, B port size

Cam Lever(-01) 30" 2.29o.71 45. 0.98 (0.3) ffiffiffi CHANGING PUSH BUTTONS One-WayCam Lever(-02) 30" 2 29(O.71 45" 0.98 (0.3) Plunqer(-05) 0.65 (0.2) Roller Plunoer. Inllne {{6) 30' 0.98 (0.3) Roller Plunoer.

or less 100 70 30 3 100 15 1 LEC 11.

It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less.

500 400 300 200 100 100 500 400 300 200 100 CNA Maximum speed: V (mm/s) Maximum speed: V (mm/s) CNS Graph (6) Graph (3) 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa CLS 3000 3000 CLQ 2000 2000 MLGP 160 140 RLQ 1000 1000 Load weight: m (kg) Load weight: m (kg) 700 800 900 700 800 900 125 MLU 600 600 160 500 500 ML1C 400 400 140 320 125 300 300 D200 200 -X 280 20100 100 100 500 400 300 200 100

Relationship between the kinematic viscosity 50 0 1 2 3 4 5 10 20 30 40 50 100 Viscosity (mPas) Transfer is possible up to about 100 mPas.

55 70 90 26 45 45 70 70 100 17 8 21.5 15.2 15.2 D 19 10 24 18.5 18.5 H 22 Connection threads 12 25 20.9 20.9 Reference dimension for R threads after installation Note 1) D indicates the maximum diameter. 6 Clean One-Touch Fittings Series KP Dimensions (mm) 1in = 25.4mm, 1g = 0.0353oz Straight Union: KPH Effective area mm Note 1) D Model L Applicable tubing O.D. mm Weight g M 2-Applicable

55 70 90 26 45 45 70 70 100 17 8 21.5 15.2 15.2 D 19 10 24 18.5 18.5 H 22 Connection threads 12 25 20.9 20.9 Reference dimension for R threads after installation Note 1) D indicates the maximum diameter. 6 Clean One-Touch Fittings Series KP Dimensions (mm) 1in = 25.4mm, 1g = 0.0353oz Straight Union: KPH Effective area mm Note 1) D Model L Applicable tubing O.D. mm Weight g M 2-Applicable

45 70 70 100 26 35 45 55 70 90 17 8 15.2 21.5 15.2 D 19 10 18.5 24 18.5 H 22 Connection threads 12 20.9 25 20.9 Reference dimension for R threads after installation Note 1) D indicates the maximum diameter. 3 Clean One-touch Fittings Series KP Dimensions Straight Union: KPH Effective area mm Note 1) D Model L Applicable tubing O.D. mm Weight g M 2-Applicable tubing TPH TPS KPH04-00 37.4