Gripper, MHZ, Parallel Style Air Gripper. 145 lb.
Vacuum Pad, with Buffer. 145 lb. M30.
Vacuum Pad, with Buffer. 145 lb. M30.
Compact Cylinder, NCQ2-Z. 145 lb. E38.
Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.
Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.
Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.
Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.
Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.
Pin Cylinder, Double Acting, Sgl Rod. 145 lb. 371.
PTFE PUMP 230V 50/60HZ, 6 Torr 145 Lpm
Flame resistant, one-touch fitting series KR can be used for a wide range of pressures from a low vacuum up to a pressure of 145 PSI. The use of a special profile ensures positive sealing and reduced resistance when the tube is being inserted. KR fittings are effective when piping in a confined space.
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 145, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 145, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 145, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 145, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 145, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 145, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Y7BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of
18.4 ] [Effective area mm2] 8 12 6 8 10 1/4 Port size 6 10 3/8 1/4 5/16 3/8 5/16 1/2 3/8 XTO Series Model XTO-2571 XTO-1239 XTO-1719 Fluid Air Proof pressure 1.5MPa Max. operating pressure 1MPa Min. operating pressure 0.2MPa 0.1MPa 0.2MPa Pilot check valve 0.2 to 1MPa 0.1 to 1MPa 0.2 to 1MPa operating pressure Ambient and -5 to 60C (No freezing) fluid temperature Effective area mm2 6 45 145
across flats L 2 x P through A1 H E 4 x T counterbore 0.5 B S Z (mm) S Z A A1 GB P Q QA R T B C D E GA GC H J L MM Bore size 5 30 40 50 5 10 15 20 25 30 40 50 10 15 20 25 20 16 12 11 5.5 4.5 9 4 4.5 2 16 12 26 20 40 32 8 6 30 27 M6 x 1.0 M5 x 0.8 14 12.5 21.5 19 22 19 19 16 16 14 6 5 7.6 depth 6.5 81 72.5 86 77.5 91 82.5 96 87.5 101 92.5 106 97.5 116 126 100 88.5 93.5 103.5 108.5 135 145