Cooling capacity = Considering a safety factor of 20%, 93.3 W x 1.2 = 112 W Circulating Fluid Typical Physical Property Values Ethylene Glycol Solution 20% Temperature [C] Density [kg/m3] Specific heat C [J/(kgK)] 10 1.03 x 103 3.93 x 103 20 1.03 x 103 3.95 x 103 30 1.02 x 103 3.97 x 103 40 1.02 x 103 3.98 x 103 50 1.01 x 103 4.00 x 103 60 1.01 x 103 4.02 x 103 Water Density : 1 x 10 3
/8 Restrictor (36.5) Clean air filter Note) One-touch fitting 12 103 85 13.2 34.8 3 (41) 111 59 71 80.4 41 59 59 Rc 3/8 (NPT 3/8) 521 3.5 (3.5) Note) This port is unavailable.
Dimensions Grommet VQ10-G-M5 (M3) 29.2 6.1 Manual override 4.9 12.4 14.8 E 2-2.7 mounting hole 12 3.7 18.1 (Lead wire length) 300 Locking type manual override 30.7 28 11 A P (5.9) (5.9) 7 ( 4 . 1 ) 5 5 5 4.9 9.7 4.9 3-M5, (M3) (18.1) ( ): M3 Broken line: Locking type manual override 4-12-10 11 3 Port Solenoid Valve Series VQ100 Dimensions L plug connector VQ10-L-M5 (M3) 35.1 Manual override
Dimensions Grommet VQ1l0l-lGlM5 (M3) 29.2 6.1 Manual override 4.9 12.4 14.8 E 2-2.7 Mounting hole 12 3.7 18.1 (Lead wire length) 300 Locking style manual override 30.7 28 11 A P (4.1) (5.9) (5.9) 7 5 5 5 4.9 9.7 4.9 3-M5 (M3) (18.1) ( ): M3 Broken line: locking style manual override 2.9-8 Series VQ100 Dimensions L plug connector VQ1l0l-lLlM5 (M3) (37.8) 31.4 Manual override 6.1 4.9 12.4
Polyurethane Coil Tubing: Series 10-TCU For details, refer to Pneumatic Clean Series catalog. Specifications 10-TCU 10-TCU 10-TCU 10-TCU 0425B-1 0425B-2 0425B-3 0604B-1 0604B-2 0604B-3 0805B-1 10-TCU 10-TCU 10-TCU Model Tubing O.D. (mm) No. of cores 2 cores 3 cores 1 core 2 cores 3 cores 1 core 1 core 4 6 4 8 5 Tubing I.D.
Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Table 2 10 Particle concentration (particles/m) Class M3.5 [Class100] 10 10 Class M2.5 [Class10] Inner cover holding screw tightening torque [Nm] 10 Tightening torque Model Screw size Class M1.5 [Class1] CYP15 0.3 M3 x 0.5 10 CYP32 2.45 M6 x 1 10 0.01 0.1 1 10 Plate Particle diameter (m) Note
Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Table 2 10 Particle concentration (particles/m) Class M3.5 [Class100] 10 10 Class M2.5 [Class10] Inner cover holding screw tightening torque [Nm] 10 Tightening torque Model Screw size Class M1.5 [Class1] CYP15 0.3 M3 x 0.5 10 CYP32 2.45 M6 x 1 10 0.01 0.1 1 10 Plate Particle diameter (m) Note
Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Table 2 10 Particle concentration (particles/m) Class M3.5 [Class100] 10 10 Class M2.5 [Class10] Inner cover holding screw tightening torque [Nm] 10 Tightening torque Model Screw size Class M1.5 [Class1] CYP15 0.3 M3 x 0.5 10 CYP32 2.45 M6 x 1 10 0.01 0.1 1 10 Plate Particle diameter (m) Note
32 32 52 36 108 116 118 40 4 40 55 20 8 21 7 4 60 75 9 10 19 450 300 300 6.8 28 102 3.2 135 450 300 40 37 41 111 30 9 14 137 146 9 10 40 40 60 40 112 120 122 47 4 40 55 20 8 25 7 4 60 75 9 10 19 450 300 300 6.8 28 104 3.2 137 450 300 40 37 41 113 30 9 14 139 148 9 10 40 40 60 40 114 122 124 47 4 40 55 20 8 25 7 4 60 75 9 10 19 500 300 300 30 134 3.2 171 500 300 52 45 143 39 18 177 188
10 M6 x 1 8 5.5 6.5 M6 x 1 12 25 56 45 11 14 13 12 M8 x 1.25 10 6.5 7.5 M6 x 1 12 32 68 56 12 18 15 13 M10 x 1.5 12 7 8.5 M8 x 1.25 16 40 79 65 14 22.4 19 16 M12 x 1.75 15 8 10 M10 x 1.5 20 50 85 70 15 28 24 21 M16 x 2 20 9.5 11.5 M12 x 1.75 24 63 95 77 18 35.5 31 27 M20 x 2.5 24 11.5 14 M16 x 2 24 80 109 88 21 45 39 36 M27 x 3 33 15 17 M18 x 2.5 27 100 132 106 26 56 48 41 M30 x 3.5 36 17.5
A5 A5 A6 A6 A7 A7 Internal Internal A8 A8 resistance resistance 10[k ] 10[k ] 24 VDC 24 VDC A9 A9 Main circuit Main circuit power supply power supply for the input for the input A10 A10 signals signals B1 B1 B2 B2 B3 B3 B4 B4 B5 B5 Maximum output Maximum output B6 B6 current: 10 mA current: 10 mA B7 B7 Pulse input internal circuit Note2) B8 Pulse input internal circuit Note2) B8 Pulse input
Low leakage 1.3 x 10-Pam/sec Leakage:1.3 x 10-Pam/sec or less (at normal temperatures, excluding gas permeation) 10Standard value Note 1) The data indicates the leakage measured in a vacuum environment of 10-Pa. Leakage [Pam3/sec] 10Note 2) The leakage test result shown is based on a test conducted for 10 minutes after the cylinder was pressurized with helium at 0.1 MPa.
L 10-1 . 10-1 10-2 . 10-1 10-3 . 10-2 10-4 . 10-2 11 M 11-1 . 11-1 11-2 . 11-1 11-3 . 11-2 11-4 . 11-2 12 R 12-1 . 12-1 12-2 . 12-1 12-3 . 12-1 12-4 . 12-2 12-5 . 12-2 2 13 S 13-1 . 13-1 13-2 . 13-2 13-3 . 13-2 14 T 14-1 . 14-1 14-2 . 14-1 14-3 . 14-1 14-4 . 14-2 14-5 . 14-3 15 15-1 . 15-1 3 IDX-OM-W011 i i i-1 () 3 i 1 1 3 IDF Series i-1 i-1 IDX-OM-W011
The drain pipe must have a minimum pipe bore of 10 mm, and a maximum length of 5 m (when installing an optional auto drain).
Low leakage 1.3 x 10-Pam/sec Leakage:1.3 x 10-Pam/sec or less (at normal temperatures, excluding gas permeation) 10Standard value Note 1) The data indicates the leakage measured in a vacuum environment of 10-Pa. Leakage [Pam3/sec] 10Note 2) The leakage test result shown is based on a test conducted for 10 minutes after the cylinder was pressurized with helium at 0.1 MPa.
Applicable model HRR012/018--10-T/MT*1 HRR012/018/024/030--20-T HRR012/018/024/030--20-MT1 Pump Rated flow (50/60 Hz)2, 3 L/min 7 (0.36 MPa)/10 (0.42 MPa) 10 (0.42 MPa)/14 (0.40 MPa) 10 (0.32 MPa)/14 (0.32 MPa) Maximum pump head (50/60 Hz) m 50 50 50 Output W 350 550 Circuit protector A 15 15 (10 A for standard) Recommended earth leakage breaker capacity A 15 Cooling capacity4 W The cooling
5 8 28 5 M8 x 1.25 15 24 M20 x 1.5 1/8 62 116 20 ML2B 22 19.5 17 32 10 13 8 45 6 8 33.5 5.5 15 30 M26 x 1.5 1/8 62 120 M10 x 1.25 26 22 19.5 17 32 12 13 8 45 6 8 37.5 5.5 15 34.5 M26 x 1.5 1/8 64 122 M10 x 1.25 26 C J G5-S 24 21 22 41 14 16 11 50 8 10 46.5 7 21.5 42.5 M32 x 2 1/4 88 154 32 M14 x 1.5 CV (mm) Boss-cut ZZ Bore size (mm) MVGQ 20 25 32 40 103 107 CC 109 138 RB J D-X 20Data 10
RA RB T B 22 22 24.5 27.5 A 30.5 30.5 39 42.5 B 27 27 34.5 37.5 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 6 8 7 12 6 8 10 12 25 29 36 40 5 5 5.5 5.5 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1.0 32 38 47 52 5 6 8 10 3.5 3.5 4.5 5 15.5 20 25.5 28 3.5 3.5 5.4 5.4 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 6.5 6.5 9 9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 Note 1) Threaded through hole is used for the
10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.
VV5QZ25C C (12) 49 Grommet (G) (35) (5.5) (7.5) 44.5 Mounting holes 41 19.5 9.4 DIN rail clamp screw 2n-C6, C8, C10 C6: One-touch fitting for 6 C8: One-touch fitting for 8 C10: One-touch fitting for 10 U side n A 4 B 2 Manual override 5 4 SMC SMC (L3) (L4) L1 L2 3 SMC SMC 2 SMC SMC SMC 26 P=20 (12) 71 (41) 37 P=20 22.9 P=20 19.2 26.6 1 SMC A 4 B 2 Stations 11 D side 11.5 11.5 57.5 42 95