Body Size: 25, Thread: F (G), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: 1 (0.02 to 0.2MPa Setting)
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Back Flow: K (w/Backflow), Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl: 6 (Nylon Bowl), Bowl Guard: None, Drain Port: J (Body Size 20: 1/8; Body Size 30 & 40: 1/4), Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None
Body Size: 30, Back Flow: w/o Backflow, Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa
Special Applications: 10- (Clean Room Compliant), Size: 30, Backflow Function: None, Thread: F (G), Port Size: 02 (1/4), Accessory: G [Round Pressure Gauge ("20-" Type Includes Limit Indicator)], Specifications: 3 (0.008 to 0.6 MPa Setting)
Special Applications: 10- (Clean Room Compliant), Size: 30, Backflow Function: None, Thread: F (G), Port Size: 02 (1/4), Accessory: G [Round Pressure Gauge ("20-" Type Includes Limit Indicator)], Specifications: 1 (0.005 to 0.2 MPa Setting)
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: 1 (0.02 to 0.2MPa Setting)
Body Size: 30, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 20, Back Flow: w/o Backflow, Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: J (Body Size 20: 1/8; Body Size 30 & 40: 1/4), Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None
Body Size: 40, Thread: F (G), Port Size: 02 (1/4), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 30, Back Flow: w/o Backflow, Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 30, Model Type: C (Air Filter + Mist Separator + Regulator), Thread: F (G), Port Size: 02 (1/4), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: G (Round Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator
Body Size: 20, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: Y (Knob, Upward)
Body Size: 30, Back Flow: w/o Backflow, Thread: F (G), Port Size: 02 (1/4), Options: G (Round Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 8 (Metal Bowl w/Level Gauge), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: RY (R + Y)
The specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted. Boosts local line pressure without requiring additional power
The specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted. Boosts local line pressure without requiring additional power