SMC Corporation of America
Elite Part Number Search
Search Results "VM122F-03-00"

CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.

output style 16 OUT2 output mode / output style 17 Line name (left side 4 digits, right side 5 digits) 18 Display channel 19 CH1 measurement display value 20 CH2 measurement display value 21 CH3 measurement display value 22 CH4 measurement display value 23 Display OFF (No display) : Settable : Not settable (negative acknowledge) -94No.PS-OMW0012-C Value (16 Hex number) 00

01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -88No.PF-OMZ0002-A Troubleshooting If an operation

Wind mode lower side set value 12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -83No.PF-OMY0002 [Line name communication data] Value (16 hex number) 00

01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles

mode/output style 16 Line name (left side 4 digits, right side 5 digits) 17 Display channel 18 CH1 measurement display value 19 CH2 measurement display value 20 CH3 measurement display value 21 CH4 measurement display value 22 Display OFF (No display) : Settable : Not settable (negative acknowledge) -87No.PF-OMA1011-A [Line name communication data] Value (16 Hex number) 00

ERR 00: CPU Hung up ERR 01: CPU Check Failure ERR 03: Back-up Data Error ERR 04: EEPROM Writing Error ERR 05: EEPROM Input Over Times Error ERR 11: DC Power Voltage Failure ERR 12: Internal Sensor Value is High ERR 13: Internal Sensor Value is Low ERR 14: Thermostat Alarm ERR 15: Output Failure Alarm (Abnormal output) ERR 17: Cutoff/Short of Internal Sensor ERR 18: Cutoff/Short of External

When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

DXT170-176-2-01 DXT170-176-2-02 DXT170-176-2-03 DXT170-176-2-04 DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 For Series VZ300/500 With light/surge voltage suppressor With surge voltage suppressor 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC S E For VZ120 Indicator light is not available for grommet type.

Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 3/4 PT, AIRLINE EQUIPMENT, AN SILENCER, GX, AN 3/4INCH (MISC./OTHER), .43422 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?

Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 3/4 PT, AIRLINE EQUIPMENT, AN SILENCER, GB, AN 3/4INCH STANDARD (PT), .48400 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?

Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 1-1/4 PT, AIRLINE EQUIPMENT, AN SILENCER, IB, AN 1 1/4INCH STANDARD (PT), 1.27720 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?

Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, VALVE ASSY (NAR4000), AIRLINE EQUIPMENT, AR NO SIZE RATPART, .05720 lb

Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, ENDPLATE ASSY (NARM2500), AIRLINE EQUIPMENT, ARM NO SIZE RAPART, .28600 lb

Soft Start-up Valve AV2000/3000/4000/5000 How to Order AV 00 1 G 20 02 Flow direction Nil R Left to right Right to left Soft start-up valve Manual override Nil: Non-locking push type (Flush) B: Locking type (Tool required) C: Locking type (Lever) Body size 20 30 40 50 1/4 3/8 1/2 3/4,1 Thread type Rc G NPT Nil F N Light/Surge voltage suppressor None Nil S Z With surge voltage suppressor (

*1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) *1 CE compliant AV 00 20 02 B B 1 D q w e r t y u i o A Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V V + 02 1/4 V 03 3/8 V 04 1/2 V 06 3/4 V 10 1 V + e Port size 1(P), 2(A) a Mounting Nil

Clean One-touch fittings (for blowing) 04 06 08 10 12 4 6 8 10 12 Thread connection Tubing (rod) connection 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 K Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer M Plug Same dia. tubing Different dia. tubing (plug-in reducer) 4 6 8 10 12

M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.