RB J D-X 20Data 10-18-11 11 Shock Absorber: Short Type Series RBQ Series RBQ/Shock Absorber: Short Type Technical Data: Model Selection Symbol 1.
Note 1) 11 m or longer power cables are not CE Marking-compliant. Note 2) Use standard power cables for 3 m and 10 m lengths.
20 26 49 Approx. 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399
P P Dust cap SY3000-42-1 Applicable manifold base Type SS5YJ7-40 Type SS5YJ7-41 Type SS5YJ7-42 Applicable manifold base Type SS5YJ7-21P Manifold Gasket DXT199-21-11 Refer to page 92 prior to handling.
If the minimum setting unit is 1 L/min, the flow can be displayed in 1 L/min units, i.e. 10, 11, 12. Minimum setting unit N Normal condition (NOR) Reference condition for volumetric flow: 101.3 kPa, 0 C The flow measurement which is converted at normal atmospheric pressure conditions at 0 C.
If the minimum setting unit is 1 L/min, the flow can be displayed in 1 L/min units, i.e. 10, 11, 12. Minimum setting unit N Normal condition (NOR) Reference condition for volumetric flow: 101.3 kPa, 0 C The flow measurement which is converted at normal atmospheric pressure conditions at 0 C.
No.PF-OMX0007-A PRODUCT NAME Digital Flow Switch (Modular type) MODEL/ Series/ Product Number PF3A701H PF3A702H Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Names and Functions of Individual Parts 11 Definition and terminology 14 Mounting and Installation 16 Piping method 17 Wiring 19 Change the Function Settings [Function selection mode] 27 Function selection
(inch) L Model KKA 1/8" (3.18) KFG2N-01 1.9 8 7.8 H 5/32" (4) KP KFG2N-03 1.9 8 7.7 1/4" (6.35) KFG2N-07 4.6 12 9 LQ 5/16" (8) KFG2N-09 6.7 14 10.1 L MQR 3/8" (9.53) KFG2N-11 10.7 17 11.7 T 1/2" (12.7) KFG2N-13 13 19 12.8 IDK 331 KFG2 Series Applicable Fluid List How to Read the Table : Completely unaffected or largely unaffected. : May be slightly affected, but, dependent upon condition,
20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399 388 L1 L2 4-13-8 9 3
VVZ400-32A-11 pc. (Blanking plate)
OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .
OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .
(For details, refer to "Specific Product Precautions 1" on Page 11.)
AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 4 Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
rc 1o Indcale thewnnO spec l.ar ons n the specilicalion sheet Note 4) F.r exlenal pr ol oplDn, F ndca|elhe qter.a p otsp6licaton R fordre appricabre var@s as @11 Note 5) The o!
Fitting Connection Series AN10 to 30-C RoHS How to Order 10 C AN 20 Applicable one-touch fitting size Body size Symbol Port size Applicable model AN10 AN10 AN15 AN20 AN20 AN30 Symbol 10 15 20 30 06 07 08 10 11 12 6 1/4 8 10 3/8 Connection type 12 Symbol Connection type C One-touch fitting connection Specifications Fluid Compressed air Max. operating pressure Note 1) 145psi (1.0 MPa) Noise
VXA VN Solenoid valve option Nil Standard LVC Select an option mark in page 17-3-11 by Applicable Fluids Check List for special fluids outside of the standard. LVA Refer to the table (2) given below for availability.
I"P.1/4, .. . , ASP530F-N03-11 S 3/S' ~ 25.9 1 51Jtr 11 / 16" 28.6 ~6~5 ~ 61 ;a.: ~:B-.9 :2D.S 220 tU6' /36,3 . 34:7 .26~ 21.7 . . ~ A efertlllCe dll'l'lerlSlons 1 01 NPT Ihmads aller installalion 3 Speed Controller 5 . ASP w"" P;lo' Ch.,k V,'v. efles Construction Parts list .QesCr;plian ' ''' fi1t~lal , . . .
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
FLT Temperature of the circulating fluid has exceeded the limitation set by customer. 11 Continue Reservoir High Temp.