Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
C8 C10 C12 02 03 B CM With 8 One-touch fitting With 10 One-touch fitting With 12 One-touch fitting 1/4 3/8 Bottom ported 1/4 Mixed sizes Note 3) When I/O Unit is selected, it is shipped separately and assembled by customer. Refer to the attached operation manual for mounting method. Note 4) Refer to page 50 for details on enclosure.
D A L Series Part no. 10-SZ3000 SZ3000-114-2A Dimensions Applicable fitting size d Model A L D 10-KQP-04 10-KQP-06 10-KQP-08 10-KQP-03 10-KQP-07 10-KQP-09 4 16 32 6 6 18 35 8 8 20.5 39 10 5/32" 16 32 6 1/4" 18 35 8.5 5/16" 20.5 39 10 383 Cassette Type Manifold 10-SZ3000 Manifold Option DIN rail dimensions / Weight D-sub connector (25 pins) / Cable assembly Directional Control Valves Air Grippers
FOR TECHNICAL SUPPORT PLEASE CALL 1-800-762-7621 Page 6 last updated 11/03/03 10:05 AM
VSA4220-01 VSA4220-02 VSA4220-03 VSA4320-01 VSA4320-02 VSA4320-03 VSA4420-01 VSA4420-02 VSA4420-03 2 position single VA 1 4 1 8 Rc 0.60 1 8 Rc 1 8 Rc SA 2 position double 1 4 1 8 Rc 0.70 1 8 Rc VA 1 8 Rc 3 position closed center 1 4 1 8 Rc 0.86 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (
Page 4 last updated 11/03/03 10:05 AM Microprocessor-Controlled Electro-Pneumatic Regulator ITV2000 EASY PROGRAMMING GUIDE ADJUSTING THE MINIMUM AND MAXIMUM PRESSURES The ITV allows the user to customize the minimum pressure (zero point) at 0% input signal and the maximum pressure (span) at 100% input signal.
(n=2, 4, 6) 65+50(n2) n2 2 20+50( ) (n=2, 4, 6) D-H7LF 10 65 20 n2 2 D-B5 D-B6 15+50( ) (n=2, 4, 6) 20+50( ) (n=2, 4, 6) 10 75 15 75+55(n2) n2 2 D-B59W 15 75 20 D-A3lA D-G39A D-K39A D-A44A 35+30(n2) 10 100 35 100+100(n2) Mounting Bracket Auto Switch Mounting Band Refer to p.1.4-35 for part numbers of the mounting brackets.
5.16.1 Accumulated operating time reset function . 5-35 5.16.2 How to operate accumulated operating time reset function . 5-35 5.17 Warming Up Function . 5-39 5.17.1 Warming up function. 5-39 5.17.2 Setting/checking of warming up function . 5-40 5.18 Anti-Snow Coverage Function . 5-42 5.18.1 Anti-snow coverage function . 5-42 5.18.2 Setting/checking of anti-snow coverage function . 5-43
12 33 11 30 32 45 45 12 12 63 15 16 9 52 67 14 37 11 35 40 50 50 12 15 80 18 16 11 66 86 18 47 12.5 40 50 60 63 14 15 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting type CR Rear clevis with ball joint A B C D EN ER F G E L M N P H R (mm) 0.2 maxi JS15H7 -0.1 maxi H11 H13 H13 0.5 0.5 0.5 32 32.5 10.5 22 10 14 15 30 10 6.6 45 10.5 5.5 5 40 38 12 25 12 16 18 35 10 6.6 55 11 5.5
35 35 40 40 50 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 23 25 28.5 33 11 11 10 10 14 14 13 14 11 11 11 12 5.5 7 7 9 38 41 41 41 86 96 97 105.5 20 24 24 24 5 6 6 8 19.5 24 24 24 141 151 154 169 33 38 39 44 M5 x 0.8 M6 x 0.75 M8 x 1 M10 x 1.25 Up to 200 Up to 300 Up to 300 Up to 300 0.25 stroke Long Stroke/Refer to pages 9-2-30 to 9-2-32 for mounting dimensions except the table below.
There may be the case it will vary substantially depending on an ambient environment. 15 + 50 ( ) CE2 n2 2 10 15 75 (n = 2, 4, 6, ) 75 + 55 (n2) ML2B 20 + 50 ( ) n2 2 D-B59W 15 20 75 (n = 2, 4, 6, ) C J G5-S D-A3 D-A44 D-G39 D-K39 CV 10 35 100 100 + 100 (n 2) 35 + 30 (n 2) MVGQ CC Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
NT-02 NT-03 NT-04 13 5 15.0 12.5 M8 x 1.25 17 6 19.6 16.5 M10 x 1.25 22 8 25.4 21.0 M14 x 1.5 Mounting Nut Applicable pin part no. Part no.
Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
ASG22F-M5-04 ASG22F-M5-06 ASG32F-01-04S ASG32F-01-06S ASG32F-01-08S ASG42F-02-06S ASG42F-02-08S ASG42F-02-10S ASG52F-03-08S ASG52F-03-10S ASG52F-03-12S ASG62F-04-12S 4 10.6 23 28.8 11.6 25.2 18.2 M5 x 0.8 8 15.8 37.2 33.7 33.7 30.2 6 13 23.6 30.6 14 34.4 18.8 4 10.6 24.8 32 14.3 39.4 18.2 1/8 12 18.6 44 39 40 35 6 13 25.4 32.6 14.3 42.4 18.8 8 15 27.5 35.5 16 52.4 20.9 6 13 27.3 36.2 17.9
(Request):010307F5 [CR][LF] (Response):01030E00D40D02010A [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 0E Quantity of bytes to read 0007 Quantity of register to read 00D4 Information of 0h (circulating fluid discharge temperature) F5 LRC 0 Information of 0001h (Reserved)
(Request):010307F5 [CR][LF] (Response):01030E00D40D02010A [CR][LF] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 0E Quantity of bytes to read 0007 Quantity of register to read 00D4 Information of 0h (circulating fluid discharge temperature) F5 LRC 0 Information of 0001h (Reserved)
-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39