SMC Corporation of America
Elite Part Number Search
Search Results "VZM550-N01-37-F"

ZQ-OM01401-B / / ZQA No.ZQ-OM01401-B 2 1. 5 2. 9 3. 11 3.1. 11 3.2. 12 3.3. 13 3.4. 14 3.5. 16 4. 17 5. 19 6. 20 7. 21 8. 28 9. 32 10. 35 11. 37 12. 40 13. 42 1 - No.ZQ-OM01401-B /ZQA *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery

L 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 VP4 Fitting blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VQ L A Dimensions VQ4 Applicable fitting d Part No.

-01ST 1/8" 8.4 20.4 27.5 4 9.3 12.7 5/32" 9.3 20.4 27.5 13.4 21 AS221F-01-06ST AS221F-N01-03ST 34.7 R1/8 12 14.2 7 1.5 31.6 13.5 6 11.6 21 13.4 34.7 AS221F-01-08ST AS221F-N01-05ST 16.5 NPT1/8 12.7 14.2 7 1.5 31.6 3/16" 13.2 24 31.1 18.5 25.3 32.4 8 15.2 23 23 AS221F-01-10ST AS221F-N01-07ST 15.3 17 1/4" 13.2 23.9 31 21 33.1 40.2 10 18.5 25 25 AS221F-02-04ST AS221F-N01-09ST 18.5 15.2 25.3 32.4

KT-VBA22A-7N KT-VBA22A-8N AN30-N03 ANA1-N03 G27-20-01 G27-P20-01-X30 AN20-N02 G36-10-N01 G36-P10-N01-X30 AN40-N04 ANA1-N04 G27-20-N01 G27-P20-N01-X30 AN40-N04 ANA1-N04 G PVQ N S L Silencer High-noise reduction silencer Elbow for silencer AN40-N04 ANA1-N04 KT-VBA10A-18N KT-VBA10A-18N VY1 Note 1) In the case of options GN, two pressure gauges and one silencer are included in the same container

-RA Both ends tapped (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33 7.5 10.5 45 43 34.4 Rc1/8 NPT1/8 NPT1/8 G1/8 7.5 10.5 G1/8 Rc1/8 NPT1/8 NPT1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc1/8 NPT1/8 NPT1/8 G1/8 8 11 G1/8 56.5 39.5 8 11 52 50 41.4 Rc1/8 NPT1

Metric Long stroke Standard stroke Without auto switch With auto switch A Long stroke L1 24 25.5 28.5 32.5 Long stroke (mm) Standard stroke (mm) Standard C Bore (mm) Bore (mm) With/Without auto switch A C1 H1 X Inch L1 14 15.5 18.5 22.5 B 22 22 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 A B 32 32 41 44 F 7.5 7.5 9 11 L B 17 17 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 Metric 6 8 7 12 12 16 20 25 12 16 20 25 9 10

B E YA 03 Applicable air cylinder bore size mm 03 05 32, 40 50 Bore size (mm) B D E F M T1 T2 Part no.

13 70 94 11 35 32 50 6.8 11 depth 8 28 16.5 M6 X 1depth12 135 73.5 26.5 118 16 75 15 40 37 50 8.6 14 depth 10 29 160 86.5 31.5 140 104 19 M8 X 1.25 depth 16 75, 100, 125, 150, 200, 250, 300 MXP 16 75 15 40 37 50 8.6 14 depth 10 30 160 86.5 31.5 140 104 19 M8 X 1.25 depth 16 19 18 45 42 80 17 depth 12 35 142 22 M10 X 1.5 depth20 194 170 110 95 37 10.5 MG Bore size (mm) H GR GQ GL O GK J N

N] F=-q x PA+w x PC F=q x PA+(e-q) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.

3.5 4 34 100 D x 100 (= E) 8 F B Note 1) When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 2 mm or more because of round chamfering.

2 2-M2 x 0.4 depth 2.2 12 Metal stopper 11-/22-MXP6-10 Max. 10.5 F 4-M3 x 0.5 depth 3 12 2-M2 x 0.4 depth 3 (mm) E F H J M Q QL S W Y Z AA Model 23 25 38 33.5 37 28 8 5 42 22 45 2 11-/22-MXP6-51 30 35 42 48.5 47 37 11 10 53 27.5 60 9.5 11-/22-MXP6-10 101 Air slide table MXP/MXPJ6 11221122Dimensions: MXP10 2-M3 x 0.5 depth 5 Z 3 Metal stopper V K C 4 5 C Max. 5.5 20 G Without stroke adjuster

N] F=-q x PA+w x PC F=q x PA+(e-q) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.

F G(PF) Dust Tight/Jet Proof (IP65) Optional IP65 model is available on valves with DIN connector electrical entry. How to Order Valve (Applicable to VQZ2000/3000 rubber seal) VQZ3151 5YZB 03 W IP65 rated No (Standard) (1) IP65 reted W Note 1) The pilot exhaust of the IP65 valves is common with main valve exhaust.

-01SD 1/8" 8.4 4 9.3 27.5 20.4 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-01-06SD AS221F-N01-03SD 6 11.6 13.5 35.6 R 1/8 14.2 7.2 1.2 31.6 12 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-01-08SD AS221F-N01-05SD NPT 1/8 12.7 14.2 7.2 35.6 1.2 31.6 8 15.2 18.5 32.4 25.3 AS221F-01-10SD AS221F-N01-07SD 1/4" 13.2 23.9 31 18.5 10 18.5 21 40.2 15 33.1 AS221F-02-04SD AS221F-N01-09SD 5/16" 15.2 25.3 32.4 21 15

-01ST AS221F-01-04ST 1/8" 8.4 4 20.4 27.5 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 13.5 12 R 1/8 14.2 7 35.6 1.5 31.6 6 11.6 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT 1/8 12.7 14.2 7 35.6 1.5 31.6 18.5 25.3 32.4 8 15.2 AS221F-N01-07ST AS221F-01-10ST 1/4" 13.2 23.9 31 18.5 15 21 33.1 40.2 10 18.5 AS221F-N01-09ST AS221F-02-04ST 15 5/16" 15.2 25.3

16 18 107 45 170 110 80 M12 X 1.75Depth21 22 M10 X 1.5Depth20 17Depth12 37 10.5 194 42 19 23 142 Bore (mm) WH W V U T S R Q J O I N Z P M Y L X K Wq 20 25 32 40 50 23 36 40 86 12 26 12 21 44 M6 X 1 25 25 140 M5 X 0.8 38 80 80 30 60 30 25 44 47 98 13 31 12 21 52 M6 X 1 30 32 153 M5 X 0.8 46 80 95 37 70 30 50 53 112 16 28.5 38 12 21 60 M6 X 1 35 32 161 Rc(PT)1/8 50 82 105 37 80 25 60 63 132

01 02 2 position double: VFS2200-F-01 02 3 position closed center: VFS2300-F-01 02 3 position exhaust center: VFS2400-F-01 02 3 position pressure center: VFS2500-F-01 02 2-5 mounting hole Manual override 150.5 (3 position: 158) (Non-locking) 2-5 mounting hole Manual override (Non-locking) With light/surge voltage suppressor 163.5 (3 position: 171) With light/surge voltage suppressor 1 8 (

Model A B C2 D E F Vacuum inlet direction q Pad dia.

Specifications Positive COM AXT661-14A-F Single (2 wire) VQ4 Negative COM AXT661-14AN-F Positive COM AXT661-13A-F VQZ Double (latching) (3 wire) Negative COM AXT661-13AN-F VQD Note) Lead wire length: 300mm Note) The parts numbers above are applicable to VQ0/1000 (2 to 16 stations) and 13 14 VQ2000 (2 to 10 stations). VQ2000 (11 to 16 stations) uses AXT661 A (N)F425. VZS VFS 3.