Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge Voltage
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: J (w/Indicator, Right Flange Surface), Version: 2, Auto Switch: M9P--Solid State, Gen.
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge Voltage Suppressor
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: K (w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface), Version: 2, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector)
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH VACUUM VALVE, VACUUM SERIES, XLA HIGH VACUUM VALVE, 2X, XLA NO SIZE RATING, 4.09783 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH VACUUM VALVE, VACUUM SERIES, XLA HIGH VACUUM VALVE, 2X, XLA NO SIZE RATING, 1.32277 lb
Variation: D (2-step Control, Single Acting/Bellows Seal, O-ring Seal), Flange Size: 40, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: A93 (A93--Reed, DC Volt, AC Volt, LED, Horizontal), Lead Wire: L (3m), Number of Switches, Mounting Position: A (2 pcs, Valve Open/Closed)
Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF(NW), Port Direction: L (w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF(NW), Port Direction: L (w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Bellows Seal, Sonic Conductance: 14L/S, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-A93 reed auto
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 50, Seal Type: Bellows Seal, Sonic Conductance: 80L/S, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-A93 reed auto
Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal
Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal
Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 50, Flange Type: KF(NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Version: Legacy, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A [2 pcs (Valve Open/Closed)]
Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 63, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: L (3m), Number: A [2 pcs (Valve Open/Closed)]