Part numbers written collectively can be complicated, thus specify by using a manifold specification form.
L-04 L-06 N-04 N-06 LL-04 LL-06 S-04 S-06 4 6 L-08 8 L-10 10 L-12 12 4 6 N-08 8 N-10 10 N-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 4 6 S-08 8 S-10 10 S-12 12 0.7 1.1 1.4 1.7 2.0 Precautions Be sure to read before handling. Refer to Air Fittings & Tubing Precautions for other details. Installation Caution Cut the tube to the required length.
In the case of SRF series, when the inlet pressure is released with the condition that the pressure at outlet side is maintained, the residual pressure cannot be released. If it will be necessary to eliminate pressure from the outlet side, a circuit should be provided for residual pressure relief. 1. Open the sealed package inside a clean room.
Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Be careful so that the cover of lead wire does not enter into the crimping part.
VACUUM GENERATOR, VACUUM EJECTOR, M18, 111 lb
Connection of Lead Wire If the manual override is turned by 180 clockwise and the mark is adjusted to 1, then pushed in the direction of an arrow (), it will be locked in the ON state. If the manual override is turned by 180 counterclockwise and mark is adjusted to 0, locking will be released and the manual override will return.
Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 Weight (g) KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 43 43 61 61 94 94 84 84 117 117 183 183 O.D.
VEA1 0, VE P F Previous Type VBA VBAT Caution P F VE 0 must be used in conjunction with the power amplifier VEA1 . The previous VE 0 cannot be used in combination with the current VEA25 , and the current VE 1 cannot be used in combination with the previous VEA1 .
If the socket is to be re-used, reposition the hook again.
Be careful with the molded coil because it generates heat while current is applied to it. 3. Lubrication This product can be used without lubrication. But if lubricated, use turbin oil Class 1, ISO VG32 (with no additive). It is impossible to use spindle oil, machine oil, or grease. 4.
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
If mounted in the wrong direction, the equipment to be connected may cause malfunction. Refer to external dimensions in pages 1423 to 1428, and then mount it.
The product cannot be used in a strong magnetic field.
06 R Mixed mounting is possible with vacuum ejector series ZM.
13.7 1/4" 28 21 4 9.3 14 10 12.5 3.5 AS2001F-06-3 AS2001F-03-3 44.8 6.3 21.8 49.1 43.6 9.3 40.7 13.5 12.7 20.7 48 42.5 5/32" 5.2 29 28 6 11.6 AS2051F-06-3 AS2001F-05-3 53.2 6.7 25.7 53.5 48.1 11.4 50 17 16.5 21.6 48.9 43.4 3/16" 6.2 49 34 14 10 3.5 12.5 6 12.8 17 13 15.5 3.5 AS2051F-08-3 AS2001F-07-3 59.8 8.1 27 54.8 49.4 13.2 52.2 18 17 22.5 49.8 44.3 7.1 1/4" 54 37 8 15.2 AS3001F-06-3
Note 2) Meter-out and meter-in types can be visually differentiated by the flow direction symbol on the resin body. Note 3) Brass parts are all electroless nickel plated, provided as standard.
The set pressure can be adjusted by turning adjustment screw 4, which adjusts the spring force. 1.9-4
Filtration degree should be 5 m or less. ( ): VHS500 5-8-18
-01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different conditions, make determinations after using the P/A