There is a maximum 46% reduction in size, reducing required maintenance space. The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360° monitoring. The modular design of the AF allows connection with other SMC air preparation equipment. The series is available in body size 20, 30 and 40. AIR FILTER, MODULAR F.R.L.. FILTER. 0.18000 lb. FVD.
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, 95 lb
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket
Rated Flow Range: 11 [2 to 100 (50) L/min], Port Size: Rc1/4, Output Specification: Out 1: PNP; Out 2: PNP, Unit Specification: w/Units Selection Function, Operation Manual: None, Calibration Certificate: None, Lead Wire: Lead Wire w/Connector, Rubber Cover, Option: Bracket
Rated Flow Range: 11 [2 to 100 (50) L/min], Port Size: Rc1/4, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V, Unit Specification: Fixed SI Unit, Operation Manual: Japanese and English, Calibration Certificate: None, Lead Wire: Lead Wire w/Connector, Rubber Cover, Option: Bracket
Rated Flow Range: 25 [0.5 to 25 (12.5) L/min], Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V, Unit Specification: Fixed SI Unit, Operation Manual: Japanese and English, Calibration Certificate: None, Lead Wire: Lead Wire w/Connector, Rubber Cover, Option: Bracket
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: Unit Switching Function, Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket for w/o Flow Adjustment
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket for w/o Flow
Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket for w/o Flow
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket for w/o Flow Adjustment Valve
Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket for w/o Flow Adjustment Valve
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket for w/o Flow Adjustment
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom Side), Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, .66138 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, .66138 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71092%8%0.2 to 7.0 l/min0.2 to 7.4 l/min0 to 7.4 l/min3.80 V15.2 mA