400 500 100 200 300 400 600 500 100 200 300 400 600 Load (N) Load (N) Load (N) 8-7-5 6 Long Stroke Slide Table Series MXW 8, 12, 16, 20, 25 How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
/200 to 220VAC (50/60Hz) Single phase, 220, 240/200 to 240VAC (50Hz) Power source 225 275 205 240 182 189 250 350 220 280 265 275 305 380 300 350 280 295 340 415 325 375 332 50Hz 60Hz 50Hz 60Hz 50Hz 50Hz 50Hz 100 VAC 200 VAC Power consumption (W) 220 to 240VAC 220VAC 240VAC JIS Symbol 10 (for 100VAC), 5 (for 200VAC) Air cooled R134a Circuit breaker (A) Note 3) Refrigerated air dryer
Cylinder series Bore size (mm) Technical Data 20 25 32 40 CDM2, CDBM2 CDLM2 BM3 020 BM3 025 BM3 032 BM3 040 Part No. of auto switch mounting band Cylinder series Bore size (mm) 20 25 32 40 50 63 80 100 125 140 160 180 200 CDA1, CDBA1, CDV3 BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M CDVS, CDLA, CE2, CNA CDL1 BS1 -125 BS1 -140 BS1 -160 CDS1 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1
Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
200/230VAC Note) Refer to pages starting with 205 for driver dimensions.
Ball screw 0.03 80 3 100 Slide screw 0.05 200 2 Guide rod type Series LXP 200 3 Slide screw 0.05 100 4 Without motor brake 30 Ball screw 0.03 6 80 Ball bushing guide 100 Slide screw 0.05 Sanyo Denki Co., Ltd. 200 2 200 3 Slide screw 0.05 100 4 With motor brake 30 Ball screw 0.03 5 80 100 Slide screw 0.05 200 3 High rigidity slide table type Series LXS 200 4.5 Slide screw
210.5 15 167 180 200 210.5 16 177.5 190.5 212.5 223 17 188 201 225 235.5 10 114.5 127.5 150 160.5 11 125 138 162.5 173 12 135.5 148.5 175 185.5 5 62 75 100 110.5 6 72.5 85.5 112.5 123 7 83 96 125 135.5 8 93.5 106.5 137.5 148 9 104 117 137.5 148 3 41 54 75 85.5 4 51.5 64.5 87.5 98 L1 L2 L3 L4 2.10-14 VQZ100/200/300 Body Ported Dimensions: VQZ200 Station VV3QZ22C (5.5) (35) 2-4.5 Mounting
Note 2) DIN is applicble to VQZ 200 and 300. Note 3) Electrical entry of pilot valve for VQZ100(L and M) is opposite side of valve body part number.
2 Slide screw 0.05 Without motor brake Series LXF 30 Direct acting guide Ball screw 0.03 80 3 100 0.05 Slide screw 200 2 Guide rod type Series LXP 200 3 0.05 Slide screw 100 4 Without motor brake 30 Ball screw 0.03 6 80 Ball bushing guide 100 Slide screw 0.05 200 2 200 3 Slide screw 0.05 100 4 With motor brake 30 Ball screw 0.03 5 80 100 Slide screw 0.05 200 3 Slide table
Note 2) Except double (latching). 5 6 Low wattage type Y (2) Note) 200/220 VAC models are applicable to the F and L kits.
Load weight Allowable moment E-MY2H/m3 E-MY2H/M3 E-MY2H/M1 E-MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 q r w et 20 20 20 20 Moment (Nm) Moment (Nm) Moment (Nm) Moment (Nm) 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 MY2H16 4 4 3 3 3 3 MY2H16 MY2H16 2 2 2 2 MY2H16 0.2 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300400500 1000 1500 100 200 300400500
the weight of the work piece and the body. 2) Values in parentheses are those for side mount specification. 100 200 300 400 500 600 700 800 Stroke (mm) 900 1000 1100 1200 1300 1400 1500 Weight of body without motor (kg) 650 Stroke(mm) X axis 100 13.6 150 200 15.7 250 300 17.8 350 400 19.9 450 500 22.0 550 600 24.1 1500 43.0 Stroke(mm) X axis 700 26.2 750 800 28.3 850 900 30.4 950
2 0.05 Slide screw Without motor brake Series LXF 30 Direct acting guide 0.03 Ball screw 80 3 100 0.05 Slide screw 200 2 Guide rod type Series LXP 200 3 0.05 Slide screw 100 4 Without motor brake 30 0.03 Ball screw 6 80 Ball bushing guide 100 0.05 Slide screw 200 2 200 3 0.05 Slide screw 100 4 With motor brake 30 0.03 Ball screw 5 80 100 0.05 Slide screw 200 3 Slide table
230 V (50 Hz) Three-phase 200 V (50 Hz) Three-phase 200/220 V (60 Hz) IDU37E R1 1/2 37 215.4 201.3 IDU55E 55 346.0 296.6 R2 IDU75E 75 441.4 388.4 Refer to the separate catalog.
Flow rate (slpm, N2) AZ1400T 2000 psig (13.8 MPa) 200 psig (1.4 MPa) Inlet pressure: 600 psig (4.1 MPa) 1.5 (38.1) 80 0.55 0.48 70 2.62 (66.5) Delivery pressure (MPa) Delivery pressure (psig) 0.41 60 0.34 50 0.27 40 0.69 (17.5) 0.21 30 0.14 20 2.5 (63.5) 0.07 10 A 0.00 0 0 100 200 300 400 500 600 700 800 Flow rate (slpm, N2) 0.88 (22.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) AZ1402TA
When selecting a converter by its nominal diameter, the converters oil level speed should be 0.2 m/s or less. 25 600 500 400 100 CRA1H100-180 200 20 CRA1H100-90 300 300 100 CRA1H80-180 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 200 150 CRA1H80-90 50 CRA1H63
Maximum Allowable Load MY3A, MY3B/m1 MY3A, MY3B/m2 MY3A, MY3B/m3 200 50 40 30 100 100 50 40 20 30 50 40 10 20 30 63 63 5 4 20 10 Load weight kg Load weight kg Load weight kg 63 3 40 10 40 5 4 2 3 25 5 4 1 25 40 2 3 25 0.5 0.4 16 2 1 16 0.3 16 1 0.2 0.5 0.1 0.5 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max. MY3A max. MY3B max.
200 200 200 0 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mep 1500 1500 1500 1500 L3 [mm] L3 [mm] L3 [mm] L3 [mm] m 1000 1000 1000 1000 L3 Z 500 500 500 500 0 0 0 0 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 0 10 20 30 40 50 60 Work load [kg] Work load [kg]
Status (7): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range. Status (8): TEMP READY signal turns OFF when 200 sec has passed after the temperature rises above the High range. TEMP READY alarm (AL12) is simultaneously activated.
CCT40-200 SCCS, #1 CCT63-200 SCCS, #2(#2+#13) CCT100-200 SCCS, #3(#3+#14) CCT63 SCCS, #13 CCT100 SCCS, #14 CCT100-200 SCCL, #1(#1+#12) CCT160-200 SCCL, #2(#2+#13) CCT100 SCCL, #12 CCT160 SCCL, #13 4.12-7 Air-hydro Converter Series CCT How to Order CCT 63 100 Effective oil level stroke (mm) Air-hydro converter Converter nominal size/stroke (mm) 63 100 160 50, 100, 200, 300, 400, 500