Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration Certificate
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
AS: AS, Body Size: 4 (1/2 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Thread: Metric Thread (M5)/R(PT), Port Size: 04 (1/2), Applicable Tube OD: Ø12, Option: None, Lock Nut: J (Round)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Stations: 04 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: without Option, Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: R (Pressure Switch for Vacuum w/Energy Saving Function, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: W (Energy Saving), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 12 (ø12), Seal: w/o Sealant
Size: 4 (1/2 Standard), Auto Drain: 1 (Auto Drain N.O.), Thread: N (NPT), Port Size: 04 (1/2 - AMR4000/5000), Switch: S (Pressure Switch), Adaptor: E4 (1/2)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn Locking Lever
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: P (Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: B (Bracket), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Attachment: TV (T + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: DG (D + G), Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)