1 2 3 4 5 6 7 8 9 10 11 12 13 80 0 5 10 15 20 25 30 35 40 45 50 55 60 Load capacity (N) Load capacity (pounds) 63 300 12.0 280 11.0 Distance from pivot point (inches) 260 Distance from pivot point (mm) 10.0 240 9.0 220 200 8.0 180 7.0 160 6.0 140 5.0 120 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 4.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Load capacity (N) Load capacity
to 60 Rated voltage *5 100/110/200/220/230/240/24/48 VAC 12/24 VDC Power consumption W *6 DC 4.5 7 10.5 Apparent power VA *6 AC 7 9.5 12 Coil temperature rise C *7 DC 50 55 65 AC 60 70 70 Allowable voltage fluctuation 10% or less of the rated voltage Allowable leakage voltage DC 2% or less of the rated voltage AC 5% or less of the rated voltage Coil insulation type Class B Weight kg *8 Face
Filtration degree should be 5 m or less. ( ): VHS500 1943 1944
Note 3) Clevis pins and snap rings are included with the double clevis type. 63 80 100 7-7-5 5 Series RQ Weight Basic Weight Additional Weight (g) (g) Bore size (mm) Magnet Both ends tapped style Bore size (mm) Standard stroke (mm) 25 6 12 8 181 180 171 127 32 11 6 26 17 143 180 165 151 100 35 45 175 116 20 5 6 4 159 143 137 92 40 13 6 27 17 155 214 198 196 50 14 6 53 32 243 373 348 393
Solenoid on side B 1 3 5 7 9 17 29 31 5 FE Ground Bit No. 1 1 1 3 7 5 7 5 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011-2017 SMC Corporation All Rights Reserved. Example of connection cable: EX9-AC050-1 etc. Valve manihold EX-OMP0009-A
Green 5 (DevCom) 0x1800 flashing P24 power supply reduction Power supply reduction of class B type Pin No. 2-5 is diagnosed. OFF (P24) 0x180E 1: Under the mapping error, all of the process data input and output are zero. 2: When Device disconnected is detected at port, all of the process data input is zero.
Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + + 1 1 1 2 2 2 9 9 9 SG 5 SG 5 SG 5 SG Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4. 2 XL-OMY0002 / 1 1.5 *3) 3)1 1 () 3 XL-OMY0002 1 &/ 1.52 2 ( ) 5 5 P-01-11 P-06-3 4 XL-OMY0002 2.2 A6063SUS316LSUS304 5 P11 FKM 3 3[]P8 60 , 245250Hz 30m/s 5 XL-OMY0002 /H0 H4 H5 () 510% O 0.1mm0.2mm O 9 P15 3 3P7P8 5 P11 O 10 P16
MXQ8(A,C) MXQ6B M30.5 0.9 5 MXQ12(A,C) MXQ8B M30.5 0.9 5 MXQ16(A) MXQ12B M40.7 2.1 6 MXQ20(A) MXQ16B M50.8 4.4 7 MXQ25(A) MXQ20B M61 7.4 9 2 (mm) (Nm) Max Min MXQ6(A) M30.5 1.1 4.1 2.1 MXQ8(A,C) MXQ6B M30.5 1.1 4.1 2.1 MXQ12(A,C) MXQ8B M0. 2.7 5.7 2.7 MXQ16(A) MXQ12B M0. 5.4 7.3 3.3 MXQ20(A) MXQ16B M50.8 5.4 7.3 3.3 MXQ25(A) MXQ20B M61 9.2 9 4 0.5mm , ,,, 8 3 0.02mm 2-2 5 [] 9 2-3 1.52
L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L 8 Fig 6. Position for application of grease Table 7. Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 16 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig 6, ) Pay attention to the mounting direction of the seal.
Fieldbus interface connector layout BUS OUT: M12 5-pin socket, A-coded (SPEEDCON) No. Designation Description 1 SLD Shield 2 DB Communication wire DB 3 DG Communication wire DG 4 DA Communication wire DA 5 Unused : Recommended mating M12 4-pin plug, part no. PCA-1567717. (Refer to page 28) BUS IN: M12 4-pin plug, A-coded (SPEEDCON) No.
M12 5-pin B-code (Reverse key), Socket No.
[%F.S.] 4 3 2 1 OUT side IN side 0 0 D 2D 3D 4D 5D 0 1 2 3 4 5 Straight pipe length The smaller the piping size, the more the product is affected by the length of straight piping. The straight piping length shall be a minimum of 5 times (5D) the piping size to achieve a stable measurement.
EX180-SMJ3/5 is a remote I/O station (1 station occupied, 32 inputs/32 outputs). An example of when the SI unit station number is set to 01 is shown below.
SF-OMZ0013-B 5. Replacement of the element 5-1. Stop Stop operation and reduce the filters internal pressure to atmosphere. 5-2. Removal of the cover Hold the flats of the cover and case with a wrench and unscrew. * It is possible that the element comes out together with the cover. In this case, step 5-3 is not necessary. 5-3.
We show the temperature characteristics for 0 to 50[oC] or -5 to 50[oC] based on data at 25[oC]. Ex.)
16.5 10 25.5 5 29 10 38 Bore (mm) Stroke 2.5 Bore size: 4/CJ1B4-lSU4 Symbol S Z 5 19.5 10 28.5 15 37.5 20 46.5 5 40 10 49 15 58 20 67 Bore (mm) Stroke 4 1.1-5 World Wide QS\E Support...