SMC Corporation of America
Elite Part Number Search
Search Results "VVEX4-1-6-CN"

Manifold block ISO size 1, Applicable solenoid valve:  VQ7-6, Number of stations: 1-10, Wide range of interface options, MFLD, ISO SIZE 1, VALVE, VV7* MANIFOLD ISO SERIES, QL, VV7* BASE MT 3/8, 5.89736 lb

Manifold block ISO size 1, Applicable solenoid valve:  VQ7-6, Number of stations: 1-10, Wide range of interface options, MFLD, ISO SIZE 1, VALVE, VV7* MANIFOLD ISO SERIES, QL, VV7* BASE MT 3/8, 7.71617 lb

Manifold block ISO size 1, Applicable solenoid valve: VQ7-6, Number of stations: 1-10, Wide range of interface options, MFLD, ISO SIZE 1, VALVE, VV7* MANIFOLD ISO SERIES, QL, VV7* BASE MT 3/8, 8.64600 lb

Manifold block ISO size 1, Applicable solenoid valve:  VQ7-6, Number of stations: 1-10, Wide range of interface options, MFLD, ISO SIZE 1, 4/5 PORT SOLENOID VALVE, J99, 2.74 lb

Manifold block ISO size 1, Applicable solenoid valve:  VQ7-6, Number of stations: 1-10, Wide range of interface options, INDIVIDUAL SUPPLY SPACER, ISO 1, 4/5 PORT SOLENOID VALVE, J99, 220.00000 lb

1, !2 and !3 !1 !2 !3 Gasket (for plug) PVC MXPJ6-PS MXPJ6-PS 6 O-ring NBR Piston seal Replacement Parts: Grease Pack Applied unit Grease pack part no. GR-S-010 (10 g) GR-S-020 (20 g) GR-L-005 (5 g) GR-L-010 (10 g) Guide unit Cylinder unit 122 Air Slide Table Series MXP 8, 10, 12, 16 Replacement Procedure is P.326 Construction Actuators Modular F.R.L.

Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: 01 [R 1/8(w/M5 Female)], Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 6 (0.06 MPa, 6 kPa, 6 kPa)

) Variations R 1/ 4, NPT 1/4, G 1/ 4 (With M5 male thread) URJ 1/4, TSJ 1/ 4 Port size Leak rate 1 x 10 5 Pa. m 3/ s 1 x 10 10 Pam3/s 100 kPa 1MPa 100 kPa 1 MPa Rated pressure range 0 0 0 0 100 kPa 100 kPa 2 outputs NPN or PNP Output Switch output Output voltage 1 to 5 V Analog output 16-2-27 4 High Precision, Digital Pressure Switch For General Fluids Series ZSE50F/ISE50 How to Order ISE50

CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kPa 0 to 2 0 to 2 kPa kPa 0 to 2 0 to 2 kPa kPa Accuracy: 1% F.S. 1% % F.S. F.S. 1% % F.S. F.S.

to 186 1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x

value may change 1 digit. 2 1 1 mmH2O mmHg Series PSE530 pressure sensors are also applicable.

face seal (Female) 1/2 inch face seal (Male) 1/2 inch tube weld 3/4 inch face seal (Female) 3/4 inch face seal (Male) 3/4 inch tube weld Code Purge port 1) TW6 FV8 MV8 TW8 FV12 MV12 TW12 q Inlete None Available None Available Outletr None None Available Available Code 00 M0 0B MB w e r 1) 1/4 inch face seal (Male) as standard.

Model VHS4510 VHS4510-06 VHS5510 1 (P) 2 (A) 3/4 1 1/4 3/8 1/2 3/4 Port size 1/2 1/2 3/8 3 (R) 77 1 (P) 2 (A) 27 82 125 38 55 Effective area (mm2) Push the handle and then turn. Double action construction prevents erroneous operation. 49 2 (A) 3 (R) 36 42 40 50 53 0.77 0.42 Mass (kg) 0.36 Combination with modular type FRL is possible.

NPN (1 output) + Analogue (1 to 5 V) type PF2W7--28--X560 PNP (1 output) + Analogue (1 to 5 V) type PF2W7--68--X560 NPN (1 output) + Analogue (4 to 20 mA) type PF2W7--29--X560 PNP (1 output) + Analogue (4 to 20 mA) type PF2W7--69--X560 Max. 30 V, 80 mA Internal voltage drop: 1 V or less 28: Analogue output: 1 to 5 V Max. 80 mA Internal voltage drop: 1.5 V or less 68: Analogue output: 1 to

Note 1) G1/4: Applicable to ISO1179-1 With bracket Output 43 Fixed setting: NPN open collector 1 output (Pin no. 4) + PNP open collector 1 output (Pin no. 2) A 2 1 65 PNP open collector 1 output (Pin no. 4) 4 3 Note) Mounting screws are not included.

Node address SW1 SW2 SW3 SW4 Node address SW1 SW2 SW3 SW4 0 0 0 0 0 8 0 0 0 1 1 1 0 0 0 9 1 0 0 1 2 0 1 0 0 10 0 1 0 1 3 1 1 0 0 11 1 1 0 1 4 0 0 1 0 12 0 0 1 1 5 1 0 1 0 13 1 0 1 1 6 0 1 1 0 14 0 1 1 1 7 1 1 1 0 15 1 1 1 1 0: OFF 1: ON Set the node address so that it does not duplicate the node address of other slaves.

0.1 -70 0.01 Food & Beverage, Pharmaceuticals 1 3/2 1 Odor Removal 2 1 -40 0.1 Instrumentation 1 3/2 2 3 5 -20 1.0 Abrasive Blasting 3 3 4 15 +3 5 Spray Painting 1 4/3 3 5 40 +7 25 Automation / Robotics 3 4/3 3 6 +10 Basic Air Cylinders 3 4/5 4 Outdoor Pipelines 1 2/3 1 Packaging Machines 3 4/5 3 Hand Air Tools 3 4/6 4 A Series Compressed Air Filters The selection of an air filter should

Manifold for series VEX1 power valve, Valve stations: 2 to 10, Passage specifications: Common SUP, EXH, Port sizes: 1/8, Thread types: Rc(PT), NPT, G(PF), MFLD, 6-STA, VALVE, VVX* MANIFOLD VX SERIES, PJ, VVX* BASE MT 1/4, 1.97820 lb, ModelApplicable valveValve stations Note)Port specificationsPilot typeCommon external pilot port sizePort sizeApplicable blanking plate1 (P)3 (R)2 (