SMC Corporation of America
Elite Part Number Search
Search Results "11-CDJ2F16-30-M9P"

1 Mechanical Valves Series VM Mechanical Valves Series VM Mechanical Valves SA VA Model VM1000 VM100 VM200 VM400 VZM500 VZM400 VFM300 VFM200 VM800 SA Dimensions (mm) Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 25 x 40 x 52 21 x 35 x 53 18 x 28 x 87 18 x 30 x 91 26 x 35 x 94 23 x 40 x 115 30 x 40 x 57 VA VM Courtesy of Steven Engineering

Note 3) For 16, 20 and 25, strokes up to 275, and for 32, strokes up to 225 are 11 available as made-to-order. (-XB11) Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.

(LRC) 9 Calculated value 10 End code CR 11 LF 30 - (8) 10h Write data to multiple holding register addresses Function code used to set multiple Step Data parameters, for changing to serial operation mode and to clear alarm history.

Nylon Urethane KQ2W23-M5 30 8 31 10 M5 0.8 8 9.6 37 43 10 17.5 15.5 38 42 19 2.8 2.4 41 1 8 KQ2W23-01S KQ2W23-02S 10 14 3.2 1 4 KQ2W04-M5 KQ2W04-01S 8 18 30 37.5 32 38.5 M5 0.8 11 3.0 3.0 8 10.4 1 8 4 16 4.0 4.0 23 14 10 10 1 4 KQ2W04-02S 43.5 42.5 38 11 26 KQ2W06-M5 KQ2W06-01S 30.5 40 33.5 42.5 M5 0.8 8 3 3 8 1 8 10 6 17 12.8 20 1 4 10 KQ2W06-02S 46 46.5 17 14 10.9 10.9 41 3 8 KQ2W06-03S

+0.030 0 +0.030 0 depth 2 4H9 16.5 14.5 Section AA 5 Mounting base side B D Q QL 11-/22-MXP16-30 Without magnet and switch rail 8 2-M2 x 0.4 depth 3 10.7 8.5 L 6-M5 x 0.8 depth 7 20 20 2-M3 x 0.5 depth 3.5 (mm) G H J K L M Q QL S V W Z Model 18 58 93 40 36 40 58 22 20 82 65 102 11-/22-MXP16-20 28 70 119 50 42 56 70 29 30 108 75 128 11-/22-MXP16-30 104 Precision air slide table MXP/MXPJ6

35C 200 200 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] HECR008-A Circulating fluid: Tap water Circulating fluid: Ethylene glycol 20% 2500 2500 Ambient temperature 15C 2000 2000 Cooling capacity [W] Cooling capacity [W] 1500 1500 1000 1000 Ambient temperature 25C Ambient temperature 25C Ambient temperature 35C 500

Note 2) Min. operating frequency is once in 30 days.

Proper tightening torque (Nm) Tightening torques for piping Connection thread Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 5.

Series 10-, 11CQSX Series10-,11CQ2X How to Order How to Order Clean room series 10 11 Clean room series 10 11 Relieving type Vacuum type Relieving type Vacuum type C(D)QSX B 20 10 30 A90 C(D)Q2XB 40 10 30 A73 D D With auto switch With auto switch (built-in magnet) (built-in magnet) Microspeed cylinder Mounting Microspeed cylinder Bore size 32 40 32mm 40mm Number of auto switches

B L2 Q L1 H 1(P) 2(A) L3 L4 L5 L6 C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 41 1.2 26 23 11 3.5 11 M5 M5 M5 18 29.1 16.5 VHK-B1A 29 29.1 44.5 14.5 1 27 22 16.5 26 61.6 58.2 2.0 2.0 54 51 1 8 11 41 8.6 1.2 13 3.5 18 32.6 16.5 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHK-01S-01S 1 8 1 8 30 32.6 65.2 57 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62

L1 H 1(P) 2(A) C D E F G J K L3 L4 L5 L6 L2 Q 18 61.6 58.2 2.0 2.0 29 29.1 44.5 14.5 1 27 22 16.5 26 41 29.1 16.5 3.5 11 1.2 26 23 11 30 54 51 11 M5 M5 M5 VHK-B1A VHKm-01S-M5 VHKm-M5-M5 1 8 18 41 32.6 16.5 3.5 11 44.5 14.5 1 27 22 16.5 26 8.6 1.2 13 57 13 VHK-B1A VHKm-01S-01S 1 8 1 8 32.6 65.2 VHKm-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62 66 17 VHK-B1A 44.5 14.5

L 11 148 12 160.5 13 173 14 185.5 15 198 16 210.5 17 223 18 235.5 19 248 20 260.5 VEX AMR NO. L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ITV NO.

L 11 148 12 160.5 13 173 14 185.5 15 198 16 210.5 17 223 18 235.5 19 248 20 260.5 VEX AMR NO. L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ITV NO.

9.5.1 (P.30) 3 F0 Address(0) 0 4 F0 DATA(H) 9.5.1 (P.30) 5 F0 DATA(L) 6 F0 7 F0 815 F0 H= L= 46 - 11

10 M6 x 1.0 x 18.5l 53 11.5 2-M5 x 0.8 2-9.5 counterbore depth 5.3 2-6.9 through CXS25 80 30 78 28 60 35 6 12 12 30 12 M6 x 1.0 x 18.5l 64 14 2-M6 x 1.0 2-11 counterbore depth 6.3 2-6.9 through CXS32 98 38 96 36 75 44 8 16 14 30 16 M8 x 1.25 x 23l 76 18 2-M6 x 1.0 2-11 counterbore depth 6.3 W X Y T TT U UU V Model PP Q QQ R 4-M5 x 0.8 thread depth 4.5 4-Rc 1/8 thread depth 6.5 4-Rc 1/8 thread

(C) IDF 1D 30 35 40 50 25 IDF 2D to 240D 30 35 40 45 50 Outlet air press. dew point (C) Ambient temp.

20 13 10 41 5 33.5 5 30 20 30 150 to 700 M10 X 1.25 25 22 19.5 17 9 10 10 26 13 10 45 6 37.5 5.5 30 20 34.5 150 to 700 M10 X 1.25 32 22 19.5 17 9 10 12 26 13 11 45 6 46.5 5.5 30 22 42.5 150 to 1000 M14 X 1.5 40 24 21 22 10 15 14 32 16 12.5 50 8 56.2 7 39 26.5 51 200 to 1000 ZZ NN P RR S U Z Bore size Stroke range 1 8 1 8 1 8 1 4 20 M20 X 1.5 9 146 14 217 226 150 to 700 M26 X 1.5 25 9 146

(mm) A AL B1 CD CX D E F G H H1 I K L MM N NA Bore (mm) Stroke range 0 0.033 0 0.033 0 0.033 0 0.039 20 M8 x 1.25 18 15.5 13 9 10 8 20 13 10 41 5 33.5 5 30 20 30 Up to 700 25 M10 x 1.25 22 19.5 17 9 10 10 26 13 10 45 6 37.5 5.5 30 20 34.5 Up to 700 32 M10 x 1.25 22 19.5 17 9 10 12 26 13 11 45 6 46.5 5.5 30 22 42.5 Up to 1000 40 M14 x 1.5 24 21 22 10 15 14 32 16 12.5 50 8 56.2 7 39 26.5 51

30 15 220 180 30 26 26 2 x 5.4 11 11 20 32 22 4.5 High-voltage unit full length: 220 mm High-voltage unit full length: 180 mm 31 (Full length of high-voltage unit and control unit) (Full length of high-voltage unit and control unit plus 62 mm) With bracket How to Order IZS31 180 X210 R Sensor Bar type Without bracket With bracket Note) Nil Bracket Without sensor Autobalance sensor [Body-mounting

Connection Female Thread: Rc, NPT, NPTF Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 Connection Female Thread: G Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 45 3 to 4 1/4 15 to 30 4 to 5 3/8 15 to 30 8 to