SI No. 1 COM M OUT 1 COM 0V 2 3 P OUT 1 Zone 1 4 SOL 0 0 Zone 1 ON Zone 1 11 SOL 7 7 Zone 1 ON 12 P OUT 2 Zone 2 13 SOL 8 8 Zone 2 ON Zone 2 20 SOL 15 15 Zone 2 ON 21 P OUT 3 Zone 3 22 SOL 16 16 Zone 3 ON Zone 3 29 SOL 23 23 Zone 3 ON 30 N. C. N.
75 71 Accessories Operation Manual (for installation/operation) 2 pcs.
Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM
L X P Table displacement (m) Table displacement (m) LXPB-200 LXPB-200 1500 1500 LXPB-175 LXPB-175 1000 1000 LXPB-150 LXPB-150 LXPB-125 LXPB-125 LXPB-100 LXPB-100 500 500 LXPB-75 LXPB-75 LXPB-50 LXPB-50 0 Weight (kg) 0 Weight (kg) 1 2 3 4 5 6 1 2 3 4 5 6 Displacement at the section indicated by the arrow when a load is applied to this section with the slide table fully extended.
Plug Part Number Bore size [mm] Part number Port thread type Quantity 12 (10 x 2) 16 (12 x 2) P-M3 M3 8 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) P-M5 M5 8 P-R1 Rc1/8 8 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) P-N1 NPT1/8 8 P-G1 G1/8 8 P-R2 Rc1/4 8 80 (56 x 2) 100 (71 x 2) P-N2 NPT1/4 8 P-G2 G1/4 8 * 1 set includes 8 pieces.
Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM
Unit switching Real-time switch output ( ) ZSE ISE For Air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON PSE YES CFM x 102, CFM x 101 ft3 x 101 OFF P-1 P-2 High flow rate Z I SE3 CFM = ft3/min P Window comparator mode H: Hysteresis High Flow Rate Type (For Air) PS H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON Z I SE1 2 NO OFF P-1 P-
Swivel Elbow KFG2V Metric Inch P. 324 P. 329 Metric Inch P. 325 P. 331 KDM KB KR KA KQG2 Straight Union KFG2H Female Connector KFG2F KG Metric Inch P. 324 P. 330 Metric Inch P. 326 P. 331 KFG2 KFG2 MS KKA KP LQ Union Tee KFG2T Union Nut KFG2N MQR Metric Inch P. 324 P. 330 Metric Inch P. 326 P. 331 T IDK 321 Stainless Steel 316 Insert Fittings Applicable Tubing: Metric Size, Connection Thread
= (P P) MPa Viewing the graph To generate a water flow of 4l/min at a differential pressure of 0.1MPa, an effective area with Cv factor 0.28 (VDW303) or more is required.
Inlet 77 154 235 12.5 31 62 125 250 375 625 725 900 1190 100 150 227 320 400 IDG100L-N04-P IDG100S-N04-P IDG100-N04-P IDG30L-N03-P IDG50L-N03-P IDG60L-N04-P IDG75L-N04-P IDG60S-N04-P IDG75S-N04-P IDG3-N02-PS IDG5-N02-PS IDG10-N03-P IDG20-N03-P IDG30-N03-P IDG50-N03-P IDG60-N04-P IDG75-N04-P IDG1-N02-P The membrane air dryer uses hollow fibers composed of a macro molecular membrane through
The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -74- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.
The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -79- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.
Blanking plug LQ P 07 2 Packaging Nil 1 Clean packaging Class M3.5 Standard packaging Class M5.5 Used to block fittings which are not being used.
P Ps Note 4, 5) NG NG Check kinetic energy. E Es ) Ps: Allowable pressure Refer to page 1498. ) Es: Allowable kinetic energy Refer to page 1498. OK OK Model determination Note 1) Stroke adjustment with either a bumper bolt or adjustment bolt is considered as an intermediate stop.
S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40
Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.
S 55 58 60 74 75 P M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 NY 26 28 36 42 46 NX 6 6.5 8 10 11 NC 7.5 depth 4.5 9 depth 5.5 10.5 depth 6.5 13.5 depth 8.5 17 depth 10.5 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 NS 43 45 44 54 53 N 14 15.5 16 21.5 21.5 KA 10 12 14 18 18 ND M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M12 x 1.75 NE 4.3 5.1 6.9 8.7 10.5 ZZ 69 72 75 92 96 Model MUB25 MUB32 MUB40
P K K 8 U 57 (at knob locked) DIN rail part no.
Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
SRH SRP SRF ITV Pilot regulator IC ITVH P ITVX IN OUT PVQ E VY1 The outlet pressure is twice the pilot pressure.