Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: NPT, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Bearing Style: M (Slide Bearing), Mounting: B (Basic), Bore Size: 50mm, Thread: TN (NPT), Stroke: 500mm, Lock Position: H (Rear Locking), Release of Manual: N (Non-locking Type), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke: 500mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: H (Rear Locking), Release Type: N (Non-locking Type), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: TN (NPT), Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: Built-in, Series: with End Lock, Mounting: Front Flange, Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke: 500mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Bearing Style: Slide Bearing, Mounting: Basic, Bore Size: 50mm, Thread: NPT, Stroke: 500mm, Lock Position: Rear Locking, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CBA1 100MM DBL-ACT AUTO-SW, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, SE, CBA1 100MM DBL-ACT AUTO-SW, 7.93664 lb
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
None Contact protection circuit D-A93 2.4V or less (to 20mA)/3V or less (to 40mA) D-A93V 2.7V or less Internal voltage drop 0.8V or less Indicator light Red LED lights when ON Lead wire D-A90(V), D-A93(V) Oil proof heavy duty vinyl cable, 2.7, 0.18mm2 x 2 cores (brown, blue), 0.5m D-A96(V) Oil proof heavy duty vinyl cable, 2.7, 0.15mm2 x 3 cores (brown, black, blue), 0.5m Note 1) Refer to
(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.
Contact protection box OUT() Brown [Red] Reed switch CD-P11 OUT( ) Blue [Black] Weights CD-P12 (g) D-A93(V) Brown [Red] D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Auto switch part no.
Contact protection box OUT() Brown [Red] Reed switch CD-P11 OUT( ) Blue [Black] Weights CD-P12 (g) D-A93(V) Brown [Red] D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Auto switch part no.
Internal resistance D-A93/D-A96 (With indicator light) 1 or less (Including 3m lead wire) LED Brown(Red) Contact protective box OUT(+) Brown(Red) Resistance D-A93 D-A96 Reed switch Auto switch model number Application Zener diode Relay/PLC IC circuit to CD-P11 Load voltage 100V AC 24V DC 4 to 8V DC OUT() Blue(Black) CD-P12 Blue(Black) Max. load current and load current range 5 to 20mA 5
) A93 3mL A93L PLC: Programmable Logic Controller Refer to applicable auto switch list Page 182.