, A80, D-A7lH, A80H D-A73C, A80C 54 12 Reed switch D-A79W D-J79, J79W 53 49 11 11 12 2 wire 3 wire 56 Solid state switch D-F7 4 wire 56 14 Write "L" at the end of the part number for 3 meters of lead wire.
, D-F9WV D-A9V D-M9, D-F9W D-M9V No. of auto switches mounted 2 pcs. 15 Note) 10 10 5 MK(2) 10 Note) 15 Note) 1 pc. 5 5 Note) Please consult with SMC for shorter stroke length than indicated in the table.
, D-F9WV D-A9V D-M9, D-F9W D-M9V No. of auto switches mounted 2 pcs. 15 Note) 10 10 5 MK(2) 10 Note) 15 Note) 1 pc. 5 5 Note) Please consult with SMC for shorter stroke length than indicated in the table.
, D-M9V, D-F9W, D-F9WV Note) The operating range is a guide including hysteresis, but is not guaranteed.
Minimum Strokes for Auto Switch Mounting Hydraulic Fluid Compatibility (mm) D-A7 D-A80 D-A73C D-A80C D-A7H D-A80H D-A9 D-A9V Hydraulic fluid Compatibility D-F9W D-F9WV D-F7W D-F7WV D-J79W D-F9BAL D-F7BAVL D-F7V D-J79C D-F9 D-F9V Standard mineral hydraulic fluid Compatible No. of auto switches W/O hydraulic fluid Compatible D-F7BAL D-F7NTL D-F79F D-F7 D-J79 D-F7LF D-A79W O/W hydraulic fluid
DC specifications of type "D" and "DO" is only available with 12 and 24 V DC.
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch mounting
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch
D-G5 D-K59 D-G5W D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7/C8 D-H7 D-H7W D-H7NF D-H7BAL D-C7/C8 D-C73C D-C80C D-C73C D-C80C D-B5/B6 D-G59F D-B59W Applicable bore size (mm) A A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5
/C8, D-H7 MNB CNA Hs 14.5 CNS CLS CLQ MLGP RLQ Auto switch D-B5/B6, D-G5/K5 MLU ML1C DHs 14.5 -X 20Data Auto switch D-B7/B8, D-G7/K7 Proper Auto Switch Mounting Position Auto Switch Mounting Height Auto switch model D-G5 D-K59 D-G5W D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7W D-H7BAL D-H7NF
B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
F9NV F9PV 154 154 154 Long Stroke Slide Table MXW Series 2 color indication solid state switch: D-F9BW (V), D-F9NW (V), D-F9PW (V) Switch operation range Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 49.5 28.5 24.5 24.5 24.5 24.5 B 82.5 103.5 128.5 153.5 178.5 203.5 4 MXW 8 W 35.5 14.5 10.5 10.5 10.5 10.5 V 96.5 117.5 142.5 167.5 192.5 217.5 A 48 28 28 28 28 B 107
Dimensions LLCA--C Stations 4-Mounting hole for W Y A K D L3 L2 L1 (Max.
Magnet: D (Built-in Magnet), Mounting: B (Basic), Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 190, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: D (Built-in Magnet), Mounting: B (Basic), Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 350mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector), Number: 4 pcs.