Action Double acting, Single rod Bore size (mm) 20, 25, 32, 40, 50, 63, 80, 100 Cushion None Auto switch mounting Rail mounting (D-F7BAL) Piston rod/Rod end nut material: Stainless steel (-XC6) Made to order Specifications other than above are the same as standard, basic style.
Mounting Basic Axial foot Rod flange Center trunnion Standard Rod end nut For parts made of stainless steel (-XC6), use the same specification stainless steel with the surface treatment (with hard chrome plated piston rod) (-XC68).
Double Rod M O U N T I N G N O O F S W I T C H E S B Basic C Single Clevis L Foot F Front Flange G Rear Flange U Front Trunnion T Rear Trunnion D Double Clevis N Front Nose Mount CONSTRUCTION SPECIFICATIONS 2 Pieces S 1 Piece n n number of switches Rod cover Aluminum alloy (Black Anodizing) O P T I O N S Body Aluminum alloy (Hard Alumite) XC6 Stainless Steel Rod XB6 High Temperature XB7 .
Double Rod M O U N T I N G N O O F S W I T C H E S B Basic C Single Clevis L Foot F Front Flange G Rear Flange U Front Trunnion T Rear Trunnion D Double Clevis N Front Nose Mount CONSTRUCTION SPECIFICATIONS 2 Pieces S 1 Piece n n number of switches Rod cover Aluminum alloy (Black Anodizing) O P T I O N S Body Aluminum alloy (Hard Alumite) XC6 Stainless Steel Rod XB6 High Temperature XB7 .
(Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: C+M, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: