SMC Corporation of America
Elite Part Number Search
Search Results "CH2FLB50C-400-F"

DSince there are other applicable auto switches than listed, refer to page 400 for details. For details about auto switches with pre-wired connector, refer to pages 1014 and 1015. Auto switches are shipped together, (but not assembled).

MB 32 10% 30% 50% 300 70% Stroke mm AS2201F -01-08 AS2200-01 200 100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable

RoHS How to Order Made to Order 2F 12 400 AS Lubricant: Vaseline -X12 Ex.) AS2002F-04-X12 Applicable tubing O.D.

Ionizer Additional air blow Air blow Ionized air 497 ZVB Series Dimensions C B D A C B A D F E [ZVB20] F E [ZVB40] Model A B C D D Note 1) E F F Note 2) ZVB20 211 202 212 310 351 210 297 341 ZVB40 248 392 298 349 390 400 384 428 Note 1) Dimension D is the overall height including the knob of the regulator.

ID AMG Accessory (Option) HAA7 HAA7 HAA15 HAA22 HAA37 Auto-drain Applicable model AFF Working Principle HAA7-F HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F HAA22-S HAA37-F AD402-04 Dust-protecting filter Mounting bench AM HAA37-S Inlet side air (HOT AIR) Push button switch Pilot light The accessories should be mounted by user. Misc.

F1 F 1 LLB3 Standard (100 L/min (ANR)) LLB4 High flow type (500 L/min (ANR)) F 1 Filter F With filter Port size 1 3 3N 12 One-touch fitting Rc 3/8 NPT 3/8 Restrictor Note) Use a resin fitting (no metal) for Rc and NPT thread.

VQ4 VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQZ VQD 4(A), 2(B) port 3(R) port 1(P) port 25P 26P/20P (P kit) 20P (J kit) F kit P kit J kit L kit S kit 2-3-11 12 Series SQ1000 Kit (D-sub connector kit) F Manifold Specifications Simplification and labor savings

TA DL2 TF TG A S + Stroke H NA F ZZ + Stroke Section TA With non-locking type manual override (suffix N) With locking type manual override (suffix L) HN HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)

Confirmation of allowable load weight by application Vertical downward: Press Horizontal: Chucking Vertical upward: Lifter l l m m F m F Maximum speed (mm/s) Load center of gravity position l (mm) Maximum speed (mm/s) to 300 to 500 to 700 to 300 to 500 to 100 to 200 to 300 Graph Graph Graph Graph Graph Graph Graph Graph l: The dimension for the load center of gravity position is the dimemsion

112.5 137.5 162.5 175 200 225 250 287.5 375 262.5 312.5 85.5 98 410.5 How to Order 348 373 123 148 173 185.5 210.5 235.5 260.5 298 385.5 273 323 Double check block 2 position 3 position/exhaust center R1 R1 R1 R1 VQ2000FPG 01 01 F R2 R2 R2 R2 Option IN side port size OUT side port size None With bracket DIN rail mounted (for manifold) With name plate F 01 02 C6 C8 Rc(PT)1/8 Rc

Bar length [mm] IZN10-G-100-X226 100 IZN10-G-200-X226 200 IZN10-G-300-X226 300 IZN10-G-400-X226 400 IZN10-G-500-X226 500 IZN10-G-600-X226 600 Part no.

Black 0 V G Shield Connector pin arrangement A phase output pulse G A DB phase output pulse F B H E D C -X Counter value 0 1 2 3 4 3 2 1 699

A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 ORIENTATION holes Label Drain Model Connection (Flange) 2B 8B C 2B, 3B, 4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 x l400 Anchor bolt M20 x l500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 4B, 6B 870 M20 x l500 AMF1000 14-20-48

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.

Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.

Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without

PA Max.1.2 MPa PAX PB In the case of VNC211A (N.C. 0.5 MPa) Peak pressure when valve is closed (MPa) Large valve capacity Av factor 3.0 x 10-5 to 160 x 10-5 (VNC1 to VNC7) Cv factor 49 to 100 (VNC8 to VNC9) Fluid speed (m/s) Conditions: Piping length/30 m Steel tube, full pressure/0.5 MPa 17-4-21 2 Series VNC How to Order Thread type Seal material Bracket (Valve size: 1/2/3/4) Nil B Nil F

0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 200 400 600 800 1000 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1 MPa 6 Series IR1000/2000/3000 Series IR3000 Flow rate characteristics Relief characteristics Pressure characteristics Testing methods conform to JIS B8372.