(d) Output signal (DO) forced output Output signals can be switched on/off forcibly independently of the servo status. Use this function for output signal wiring check, etc.
-14No.EX-OMP0004CN-I D 3 -15No.EX-OMP0004CN-I LED LED LED L ERR L RUN PWR ON OFF PWR(V) ON OFF -16No.EX-OMP0004CN-I DIP (0.2 Nm) -17No.EX-OMP0004CN-I 5 L ERRLED 00 65 L ERRLED HOLD/CLEAR HOLD/CLEAR No.1 HOLD ON CLEAR OFF No.2 ON 110 OFF -18No.EX-OMP0004CN-I EX260-SMJI/O (1 32 /32 ) SI [01] QJ61BT11N EX260-SMJ1/2 I/O (1 ) (RY) (RX) (RX) (RY) E0H RX0FRX00
AFG-D elementless water separator eliminates the need of filter elements, allowing for larger flow capacity and eliminating the hassle of regular maintenance. AFG-D utilizes centrifugal force to effectively separate water from compressed air, achieving 99% water droplet removal. AFG-D modular body style allows it to be installed into existing FRL systems.
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M
Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Magnet: None, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: Rc, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit
Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
NPN 1 output ISE30A-01-N-ML Digital pressure PNP 1 output ISE30A-01-P-ML NPN 1 output/ Voltage output ISE30A-01-C-ML switch Note 3) NPN 1 output/ Current output ISE30A-01-D-ML Note 1) This is an assembly of the bracket and resin panel nut. Note 2) l in part numbers for a round type pressure gauge indicates a type of connection thread.
Standard Specifications AMR3000 AMR4000 AMR5000 AMR6000 Model 1 1 4, 3 8 1 4, 3 8, 1 2 1 2, 3 4 3 4, Port size Fluid Air Proof pressure 1.5 MPa 1.0 MPa Max. operating pressure 0.05 to 0.85 MPa Setting pressure range 5 to 60C (No freezing) Ambient and fluid temperature Relieving type Construction 0.3 m Filtration Max. 1.0 mgf/Nm3 ( 0.8 ppm) (1)(2) Oil mist density in the outlet side 750 1500
D The setting time from when the input signal reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the flow can be displayed or set by the digital flow switch.
(LJ1S Series only) C D Running accuracy Model C plane to A plane D plane to B plane LJ1H10 LJ1H20 LJ1H30 LJ1S10 LJ1S20 LJ1S30 0.07 or less 0.03 or less 0.09 or less 0.12 or less 0.1 or less 0.1 or less 0.07 or less 0.06 or less 0.03 or less 0.015 or less 0.1 or less 0.1 or less B A Actuator control Programming from a PC Programming and start-up: easy programming is possible by means of the
Manual override Nil D E Non-locking push type Push-turn locking slotted type Push-turn locking lever type 12 Series SYJ3000 Common SUP/Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: A (Air Cushion), Bore Size: 50 (2"), Stroke: 1500 (15")
Manual override Nil D E Non-locking push type Push-turn locking slotted type Push-turn locking lever type 1-5-15 Series SYJ3000 Common SUP/Common EXH Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Note) X465 AMR Note) Except symbol G ITV IC Switch specifications Output specifications NPN output PNP output 1 to 5 V output 4 to 20 mA output Symbol A B C D VBA VE VY1 With digital pressure switch G PPA Note 1) Please contact SMC separately for details about the external dimensions, etc.
Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 40 (1 1/2"), Stroke: 1500 (15"), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 32 (1 1/4"), Stroke: 1500 (15"), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: A (Air Cushion), Bore Size: 32 (1 1/4"), Stroke: 1500 (15"), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)